Literature DB >> 32017173

Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Dan Zhu1,2, Wenbo Li2,3, Dapeng Liu2,3, Guanshu Liu2,3, Yigang Pei2,3,4, Taehoon Shin5,6, Farzad Sedaghat2, Qin Qin2,3.   

Abstract

PURPOSE: Most existing non-contrast-enhanced methods for abdominal MR arteriography rely on a spatially selective inversion (SSI) pulse with a delay to null both static tissue and venous blood, and are limited to small spatial coverage due to the sensitivity to slow arterial inflow. Velocity-selective inversion (VSI) based approach has been shown to preserve the arterial blood inside the imaging volume at 1.5 T. Recently, velocity-selective saturation (VSS) pulse trains were applied to suppress the static tissue and have been combined with SSI pulses for cerebral MR arteriography at 3 T. The aim of this study is to construct an abdominal MRA protocol with large spatial coverage at 3 T using advanced velocity-selective pulse trains.
METHODS: Multiple velocity-selective MRA protocols with different sequence modules and 3D acquisition methods were evaluated. Sequences using VSS only as well as SSI+VSS and VSI+VSS preparations were then compared among a group of healthy young and middle-aged volunteers. Using MRA without any preparations as reference, relative signal ratios and relative contrast ratios of different vascular segments were quantitatively analyzed.
RESULTS: Both SSI+VSS and VSI+VSS arteriograms achieved high artery-to-tissue and artery-to-vein relative contrast ratios above aortic bifurcation. The SSI+VSS sequence yielded lower signal at the bilateral iliac arteries than VSI+VSS, reflecting the benefit of the VSI preparation for imaging the distal branches.
CONCLUSION: The feasibility of noncontrast 3D MR abdominal arteriography was demonstrated on healthy volunteers using a combination of VSS pulse trains and SSI or VSI pulse.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  abdominal MRA; arteriography; non-contrast-enhanced MRA; velocity-selective pulse train

Mesh:

Substances:

Year:  2020        PMID: 32017173      PMCID: PMC7263981          DOI: 10.1002/mrm.28187

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  A simple geometrical description of the TrueFISP ideal transient and steady-state signal.

Authors:  P Schmitt; M A Griswold; V Gulani; A Haase; M Flentje; P M Jakob
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

2.  Steady-state free precession MRA of the renal arteries: breath-hold and navigator-gated techniques vs. CE-MRA.

Authors:  Jeffrey H Maki; Gregory J Wilson; William B Eubank; David J Glickerman; Sudhakar Pipavath; Romhild M Hoogeveen
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

3.  Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging with three-dimensional half-fourier fast spin-echo and true steady-state free-precession sequences.

Authors:  Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Toshikazu Kamae; Shigeki Arizono; Yuusuke Hirokawa; Toshiya Shibata; Kaori Togashi
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

Review 4.  Non-contrast-enhanced MR angiography of the abdomen.

Authors:  Mitsue Miyazaki; Hiroyoshi Isoda
Journal:  Eur J Radiol       Date:  2011-02-16       Impact factor: 3.528

5.  Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging.

Authors:  Robert J McDonald; Jennifer S McDonald; David F Kallmes; Mark E Jentoft; David L Murray; Kent R Thielen; Eric E Williamson; Laurence J Eckel
Journal:  Radiology       Date:  2015-03-05       Impact factor: 11.105

6.  Vascular Imaging With Ferumoxytol as a Contrast Agent.

Authors:  Michael D Hope; Thomas A Hope; Chengcheng Zhu; Farshid Faraji; Henrik Haraldsson; Karen G Ordovas; David Saloner
Journal:  AJR Am J Roentgenol       Date:  2015-06-23       Impact factor: 3.959

7.  Distribution of blood flow velocity in the normal aorta: Effect of age and gender.

Authors:  Julio Garcia; Roel L F van der Palen; Emilie Bollache; Kelly Jarvis; Michael J Rose; Alex J Barker; Jeremy D Collins; James C Carr; Joshua Robinson; Cynthia K Rigsby; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-05-26       Impact factor: 4.813

Review 8.  Magnetic resonance angiography: current status and future directions.

Authors:  Michael P Hartung; Thomas M Grist; Christopher J François
Journal:  J Cardiovasc Magn Reson       Date:  2011-03-09       Impact factor: 5.364

Review 9.  Abdominal MRI at 3.0 T: the basics revisited.

Authors:  Elmar M Merkle; Brian M Dale
Journal:  AJR Am J Roentgenol       Date:  2006-06       Impact factor: 3.959

10.  Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.

Authors:  Taehoon Shin; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-11-28       Impact factor: 4.668

View more
  8 in total

1.  A revisit of the k-space filtering effects of magnetization-prepared 3D FLASH and balanced SSFP acquisitions: Analytical characterization of the point spread functions.

Authors:  Dan Zhu; Qin Qin
Journal:  Magn Reson Imaging       Date:  2022-02-01       Impact factor: 2.546

2.  Three-dimensional whole-brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform-based velocity-selective pulse trains.

Authors:  Wenbo Li; Dapeng Liu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2021-05-06       Impact factor: 4.668

3.  Ensuring both velocity and spatial responses robust to B 0 / B 1 + field inhomogeneities for velocity-selective arterial spin labeling through dynamic phase-cycling.

Authors:  Dapeng Liu; Wenbo Li; Feng Xu; Dan Zhu; Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-12-08       Impact factor: 4.668

4.  A novel spectrally selective fat saturation pulse design with robustness to B0 and B1 inhomogeneities: A demonstration on 3D T1-weighted breast MRI at 3 T.

Authors:  Feng Xu; Wenbo Li; Dapeng Liu; Dan Zhu; Michael Schär; Kelly Myers; Qin Qin
Journal:  Magn Reson Imaging       Date:  2020-10-29       Impact factor: 2.546

5.  Ultrafast B1 mapping with RF-prepared 3D FLASH acquisition: Correcting the bias due to T1 -induced k-space filtering effect.

Authors:  Dan Zhu; Michael Schär; Qin Qin
Journal:  Magn Reson Med       Date:  2022-04-05       Impact factor: 3.737

6.  T2 -oximetry-based cerebral venous oxygenation mapping using Fourier-transform-based velocity-selective pulse trains.

Authors:  Wenbo Li; Feng Xu; Dan Zhu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2022-05-24       Impact factor: 3.737

Review 7.  Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation.

Authors:  Qin Qin; David C Alsop; Divya S Bolar; Luis Hernandez-Garcia; James Meakin; Dapeng Liu; Krishna S Nayak; Sophie Schmid; Matthias J P van Osch; Eric C Wong; Joseph G Woods; Greg Zaharchuk; Moss Y Zhao; Zungho Zun; Jia Guo
Journal:  Magn Reson Med       Date:  2022-07-12       Impact factor: 3.737

8.  Magnetic resonance angiography and perfusion mapping by arterial spin labeling using Fourier transform-based velocity-selective pulse trains: Examination on a commercial perfusion phantom.

Authors:  Feng Xu; Dan Zhu; Hongli Fan; Hanzhang Lu; Dapeng Liu; Wenbo Li; Qin Qin
Journal:  Magn Reson Med       Date:  2021-05-02       Impact factor: 4.668

  8 in total