Literature DB >> 25928314

Normal values for cardiovascular magnetic resonance in adults and children.

Nadine Kawel-Boehm1, Alicia Maceira2, Emanuela R Valsangiacomo-Buechel3, Jens Vogel-Claussen4, Evrim B Turkbey5, Rupert Williams6, Sven Plein7, Michael Tee8, John Eng9, David A Bluemke10.   

Abstract

Morphological and functional parameters such as chamber size and function, aortic diameters and distensibility, flow and T1 and T2* relaxation time can be assessed and quantified by cardiovascular magnetic resonance (CMR). Knowledge of normal values for quantitative CMR is crucial to interpretation of results and to distinguish normal from disease. In this review, we present normal reference values for morphological and functional CMR parameters of the cardiovascular system based on the peer-reviewed literature and current CMR techniques and sequences.

Entities:  

Mesh:

Year:  2015        PMID: 25928314      PMCID: PMC4403942          DOI: 10.1186/s12968-015-0111-7

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


Introduction

Quantitative cardiovascular magnetic resonance (CMR) is able to provide a wealth of information to help distinguish health from disease. In addition to defining chamber sizes and function, CMR can also determine regional function of the heart as well as tissue composition (myocardial T1 and T2* relaxation time). Advantages of quantitative evaluation are objective differentiation between pathology and normal conditions, grading of disease severity, monitoring changes under therapy and evaluating prognosis. Knowledge of normal values is required to interpret the disease state. Thus, the aim of this review is to provide normal reference values for morphological and functional CMR parameters of the cardiovascular system based on a systematic review of the literature using current CMR techniques and sequences. Technical factors such as sequence parameters are relevant for CMR, and these factors are provided as in relationship to the normal values. In addition, factors related to post processing will affect the CMR analysis, and these factors are also described. When multiple peer-reviewed manuscripts are available for normal values, we describe the criteria used to select data for inclusion into this review. When feasible, we provide weighted means based on these literature values. Finally, demographic factors (e.g. age, gender, and ethnicity) may have an influence on normal values and are specified in the review.

Statistical analysis

Results from multiple studies reporting normal values for the same CMR parameters were combined using a random effects meta-analysis model as implemented by the metan command [1]. This produced a weighted, pooled estimate of the population mean of the CMR parameters in the combined studies. Upper and lower limits were calculated as ±2SDp, where SDp is the pooled standard deviation calculated from the standard deviations reported in each study [2]. Statistical analyses were performed with the Stata software package (version 13.1, StataCorp, College Station, TX).

Left ventricular dimensions and functions in the adult

CMR acquisition parameters

The primary method used to assess the left ventricle is steady state free precession (SSFP) technique at 1.5 Tesla. Steady-state free precession (SSFP) technique yields significantly improved blood-myocardium contrast compared to conventional fast gradient echo (FGRE). However, at 3 Tesla, fast gradient echo CMR may also be used. To date however, no studies have presented normal data at 3 Tesla. The derived cardiac volumes and ventricular mass are known to differ for SSFP and FGRE CMR, so that normal ranges are different for each method [3]. Publications presenting reference values of the left ventricle based on the SSFP technique are listed in Table 1.
Table 1

References, normal LV function and dimensions, SSFP technique, axial imaging

First author, year CMR technique N, male: female Age range (yrs)
Alfakih, 2003 [3]Short axis SSFP, papillary muscle included in LV mass30:3020-65
Hudsmith, 2005 [4]Short axis SSFP, papillary muscle included in LV mass63:4521-68
Maceira, 2006 [5]Short axis SSFP, papillary muscle included in LV mass60:6020-80

SSFP = steady-state free precession; LV = left ventricle; yrs = years.

References, normal LV function and dimensions, SSFP technique, axial imaging SSFP = steady-state free precession; LV = left ventricle; yrs = years.

CMR analysis methods

Papillary muscle mass has been shown to significantly affect LV volumes and mass [6]. No uniformly accepted convention has been used for analyzing trabeculation and papillary muscle mass [7]. Papillary muscle mass has been noted to account for approximately 9% of total LV mass using FGRE technique [6]. Thus, tables of normal values should specify the status of the papillary muscles in the CMR analysis. Tables 2 and 3 provide normal values based on papillary muscle mass added to the remainder of the myocardial mass.
Table 2

Left ventricular parameters, ages 20–80

Men Women
mean p SD p Lower/ upper limits* mean p SD p Lower/ upper limits*
EDV [ml]16027106-2141322386-178
EDV /BSA [ml/m2]811257-105761056-96
ESV [ml]541426-82441122-66
ESV/BSA [ml/m2]**26614-3824514-34
SV [ml]1081872-144871557-117
SV/BSA [ml/m2]**54642-6652738-66
EF [%]67557-7767557-77
Mass [g]1342192-176982156-140
Mass/BSA [g/m2]67949-85611041-81

LV papillary muscle mass included as part of LV mass. Pooled weighted mean values from references [3-5]. Meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; **from references [4,5] only.

Table 3

Left ventricular parameters, by age and gender [mean ± SD (lower, upper limits*)]

Men Women
Parameter <60 years ≥60 years <60 years ≥60 years
EDV [ml]161 ± 21 (119, 203)148 ± 21 (106, 190)132 ± 21 (90, 174)120 ± 21 (78, 162)
EDV /BSA [ml/m2]82 ± 9 (64, 100)76 ± 9 (58, 94)78 ± 8.7 (61, 95)69 ± 8.7 (52, 86)
ESV [ml]55 ± 11 (33, 77)48 ± 11 (26, 70)44 ± 9.5 (25, 63)38 ± 9.5 (19, 57)
ESV/BSA [ml/m2]28 ± 5.5 (17, 39)25 ± 5.5 (14, 36)26 ± 4.7 (17, 35)22 ± 4.7 (13, 31)
SV [ml]106 ± 14 (78, 134)100 ± 14 (72, 128)88 ± 14 (60, 116)82 ± 14 (54, 110)
SV/BSA [ml/m2]55 ± 6.1 (43, 67)52 ± 6.1 (40, 64)52 ± 6.2 (40, 64)47.5 ± 6.2 (35, 60)
EF [%]66 ± 4.5 (57, 75)68 ± 4.5 (59, 77)67 ± 4.6 (58, 76)69 ± 4.6 (60, 78)
Mass [g]147 ± 20 (107, 187)145 ± 20 (105, 185)106 ± 18 (70, 142)110 ± 18 (74, 146)
Mass/BSA [g/m2]74 ± 8.5 (57, 91)73 ± 8.5 (56, 90)62 ± 7.5 (47, 77)63 ± 7.5 (48, 78)

LV papillary muscle mass included as part of LV mass. From reference [5].

* = calculated as mean ±2*SD; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation.

Left ventricular parameters, ages 20–80 LV papillary muscle mass included as part of LV mass. Pooled weighted mean values from references [3-5]. Meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; **from references [4,5] only. Left ventricular parameters, by age and gender [mean ± SD (lower, upper limits*)] LV papillary muscle mass included as part of LV mass. From reference [5]. * = calculated as mean ±2*SD; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation. The majority of software approaches use a combination of semi-automated feature recognition combined with manual correction of contours. Short-axis images are most commonly analyzed on a per-slice bases by applying the Simpson’s method (“stack of disks”) [8]. An example of left ventricular contouring is shown in Figure 1.
Figure 1

LV contouring. Note that LV papillary muscle mass has been isolated and added to left ventricular mass.

LV contouring. Note that LV papillary muscle mass has been isolated and added to left ventricular mass.

Demographic parameters

Gender has been demonstrated to have significant independent influence on ventricular volumes and mass. All absolute and normalized volumes decrease in relationship to age in adults [5] in a continuous manner. When considering younger (e.g. <65 years) versus older adults (≥65 years), most studies have shown significant differences in normal values for mass and volumes. For convenience, both average, and younger/ older normal values are given in the tables as available in the literature. An age-related normal value may be useful for patients who are at the upper or lower limits of the values in Tables 2 and 4.
Table 4

Functional and geometric parameters of the normal left ventricle in the adult, from reference [5]

Men Women
PFRE [ml/s]527 ± 140 (253, 802)477 ± 146 (190, 764)
PFRE /BSA [ml/m2]270 ± 70 (134, 407)279 ± 81 (121, 437)
PFRE/EDV [/s]3.4 ± 0.71 (2.0, 4.8)3.8 ± 0.83 (2.1, 5.4)
PFRA [ml/s]373 ± 82 (212, 534)283 ± 69 (149, 418)
PFRA/BSA [ml/m2]193 ± 44 (107, 279)168 ± 44 (82, 254)
PFRA/EDV [/s]2.6 ± 0.57 (1.5, 3.7)2.3 ± 0.49 (1.4, 3.3)
PFRE/PFRA1.4 ± 0.34 (0.7, 2.8)1.7 ± 0.29 (0.9, 3.1)
Septal AVPD [mm]15 ± 3.6 (8, 22)14 ± 3.2 (8, 21)
Septal AVPD /long length [%]15 ± 2.9 (9, 21)16 ± 3.5 (9, 23)
Lateral AVPD [mm]18 ± 4.1 (9, 26)17 ± 3.2 (11, 24)
Lateral AVPD /long length [%]17 ± 3.2 (11, 23)19 ± 3.1 (13, 24)
Sphericity index, diastole0.35 ± 0.06 (0.22, 0.48)0.4 ± 0.07 (0.27, 0.53)
Sphericity index, systole0.20 ± 0.05 (0.10, 0.29)0.23 ± 0.068 (0.09, 0.36)

Means ± standard deviation and (95% confidence intervals) are given.

BSA = body surface area; PFR = peak filling rate; E = early; A = active; AVPD = atrioventricular plane descent.

Functional and geometric parameters of the normal left ventricle in the adult, from reference [5] Means ± standard deviation and (95% confidence intervals) are given. BSA = body surface area; PFR = peak filling rate; E = early; A = active; AVPD = atrioventricular plane descent.

Studies included in this review

Multiple studies have presented cohorts of normal individuals for determining normal dimensions of the left ventricle. For the purpose of this review, only cohorts of 30 or more normal subjects by gender using SSFP CMR have been included. Only data at 1.5T is available for normal subjects using SSFP short axis imaging. Inclusion criteria for the tables below also included a full description of the subject cohort (including the analysis methods used), age and gender of subjects. One study used SSFP radial imaging, and is not included in this review [9]. Multiple studies (not shown in the tables) have used FGRE technique at 1.5T [9-13]. While FGRE is currently used at 3T in some settings, the relevance of FGRE technique at 1.5T to that at 3T is not known. Because slice FGRE acquisition parameters at 3T are different than at 1.5T, adaptation of 1.5T FGRE normal parameters to 3T FGRE imaging is not recommended. Information on ethnicity in relationship to LV parameters is not available for SSFP technique. Finally, the studies in Table 1 were all conducted in European centers. Normal values for left ventricular dimensions and functions according to these studies are presented in Tables 2, 3 and 4. Age dependent normal values for men and women are also presented in Figures 2 and 3.
Figure 2

Left ventricular volumes, mass and function in systole and diastole normalized to age and body surface area for males according to reference [ 5 ].

Figure 3

Left ventricular volumes, mass and function in systole and diastole normalized to age and body surface area for females according to reference [ 5 ].

Left ventricular volumes, mass and function in systole and diastole normalized to age and body surface area for males according to reference [ 5 ]. Left ventricular volumes, mass and function in systole and diastole normalized to age and body surface area for females according to reference [ 5 ].

Additional LV function parameters

In addition to ejection fraction, Maceira et al. have provided additional functional parameters that may be useful in some settings [5]. For diastolic function, the derivative of the time/ volume filling curve expresses the peak filling rate (PFR). Both early (E) and active (A) filling rates are provided. In addition, longitudinal atrioventricular plane descent (AVPD) and sphericity index (volume observed/volume of sphere using long axis as diameter) at end diastole and end systole are given. These latter parameters are not routinely used for clinical diagnosis.

Right ventricular dimensions and functions in the adult

For measurement of right ventricular volumes a stack of cine SSFP images acquired either horizontally or in short axis view can be used [7]. Similar to the left ventricle, analysis of the right ventricle is usually performed on a per slice basis by manual contouring of the endocardial and epicardial borders. Volumes are calculated based on the Simpson’s method [8]. The right ventricular volumes and mass are significantly affected by inclusion or exclusion of trabeculations and papillary muscles [14,15]. For manual contouring, inclusion of trabeculations and papillary muscles as part of the right ventricular volume will achieve higher reproducibility [7,14,15]. However, semiautomatic software is increasingly used for volumetric analysis, enabling automatic delineation of papillary muscles [16]. Therefore normal values for both methods are provided. An example of right ventricular contouring using a semiautomatic software is shown in Figure 4.
Figure 4

Example of RV contouring using a semiautomatic software. Note that papillary muscles were included in RV mass (arrow).

Example of RV contouring using a semiautomatic software. Note that papillary muscles were included in RV mass (arrow). Detailed recommendations for right ventricular acquisitions and post processing have been published [7]. BSA has been shown to have an independent influence on RV mass and volumes [16]. Absolute and normalized RV volumes are significantly larger in males compared to females [3,4,16]. Further, RV mass and volumes decrease with age [4,16]. Criteria regarding study inclusion are identical compared to the left ventricle. Three studies based on SSFP imaging were included (Table 5). In two studies, trabeculations and papillary muscles were included as part of the right ventricular cavity [3,4], and pooled weighted mean values of the two studies are presented in Table 6. In the third study papillary muscles were considered part of the right ventricular mass [16]. Similar to the left ventricle, data is presented as a younger age (<60 years) and an older age group (≥60 years) (Table 7). Further, age dependent normal values for men and women are presented in Figures 5 and 6.
Table 5

References, normal right ventricular function and dimensions, SSFP technique

First author, year CMR technique N, male: female Age range (yrs)
Alfakih, 2003 [3]Short axis SSFP, papillary muscles and trabeculation included in RV volume30:3020-65
Hudsmith, 2005 [4]Short axis SSFP, papillary muscles and trabeculation included in RV volume63:4521-68
Maceira, 2006 [16]Short axis SSFP, papillary muscle included in RV mass60:6020-80

SSFP = steady-state free precession; RV = right ventricle; yrs = years.

Table 6

Right ventricular parameters, ages 20–68

Men Women
Parameter mean p SD p Lower/ upper limits* mean p SD p Lower/ upper limits*
EDV [ml]18433118-2501393177-201
EDV /BSA [ml/m2]911561-121801648-112
ESV [ml]791941-117541524-84
ESV/BSA [ml/m2]**391019-59321012-52
SV [ml]1061968-144841848-120
SV/BSA [ml/m2]**57841-7353935-71
EF [%]62552-7261551-71
Mass [g]**41825-5735721-49
Mass/BSA [g/m2]**21413-2920412-28

Right ventricular trabeculations and papillary muscle mass included as part of right ventricular volume.

Pooled weighted mean values from references [3,4].

meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; **from reference [4] only.

Table 7

Right ventricular parameters, by age and gender [mean ± SD (lower/upper limits*)]

Men Women
Parameter <60 years ≥60 years <60 years ≥60 years
EDV [ml]169 ± 25 (119, 219)153 ± 25 (103, 203)133 ± 22 (89, 177)114 ± 22 (70, 158)
EDV /BSA [ml/m2]87 ± 12 (63, 111)77 ± 12 (53, 101)78 ± 9 (60, 96)66 ± 9 (48, 84)
ESV [ml]62 ± 15 (32, 92)48 ± 15 (18, 78)49 ± 13 (23, 75)35 ± 13 (9, 61)
ESV/BSA [ml/m2]32 ± 7 (18, 46)24 ± 7 (10, 38)28 ± 7 (14, 42)20 ± 7 (6, 34)
SV [ml]107 ± 17 (73, 141)105 ± 17 (71, 139)85 ± 13 (59, 111)80 ± 13 (54, 106)
SV/BSA [ml/m2]55 ± 8 (39, 71)53 ± 8 (37, 69)50 ± 6 (38, 62)46 ± 6 (34, 58)
EF [%]64 ± 7 (50, 78)69 ± 7 (55, 83)64 ± 6 (52, 76)70 ± 6 (58, 82)
Mass [g]68 ± 14 (40, 96)63 ± 14 (35, 91)50 ± 11 (28, 72)44 ± 11 (22, 66)
Mass/BSA [g/m2]35 ± 7 (21, 49)32 ± 7 (18, 46)30 ± 5 (20, 40)25 ± 5 (15, 35)

Right ventricular trabeculations and papillary muscle mass included as part of right ventricular mass. From reference [16].

EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD.

Figure 5

Right ventricular volumes, mass and function for males by age decile.

Figure 6

Right ventricular volumes, mass and function for females by age decile.

References, normal right ventricular function and dimensions, SSFP technique SSFP = steady-state free precession; RV = right ventricle; yrs = years. Right ventricular parameters, ages 20–68 Right ventricular trabeculations and papillary muscle mass included as part of right ventricular volume. Pooled weighted mean values from references [3,4]. meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; **from reference [4] only. Right ventricular parameters, by age and gender [mean ± SD (lower/upper limits*)] Right ventricular trabeculations and papillary muscle mass included as part of right ventricular mass. From reference [16]. EDV = end-diastolic volume; ESV = end-systolic volume; SV = stroke volume; EF = ejection fraction; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD. Right ventricular volumes, mass and function for males by age decile. Right ventricular volumes, mass and function for females by age decile.

Additional RV function parameters

Similar to the LV, Maceira et al. have provided additional functional parameters [16] (Table 8) that may have relevance to specific applications.
Table 8

Functional and geometric parameters of the normal right ventricle in the adult, from reference [16] [mean ± SD (95% CI)]

Men Women
PFRE [ml/s]405 ± 137 (137, 674)337 ± 117 (107, 567)
PFRE /BSA [ml/m2]207 ± 70 (68, 345)197 ± 68 (64, 330)
PFRE/EDV [/s]2.4 ± 0.75 (1.0, 3.9)2.7 ± 0.85 (1.0, 4.3)
PFRA [ml/s]489 ± 175 (146, 833)368 ± 153 (67, 668)
PFRA/BSA [ml/m2]250 ± 94 (66, 434)215 ± 89 (40, 390)
PFRA/EDV [/s]3.1 ± 1.0 (1.0, 5.2)2.9 ± 1.0 (0.9, 5.0)
PFRE/PFRA0.8 ± 0.49 (−0.1, 1.8)0.9 ± 0.46 (0.0, 1.8)
Septal AVPD [mm]15 ± 4.1 (6, 23)13 ± 3.0 (7, 19)
Septal AVPD /long length [%]17 ± 4.5 (8, 26)17 ± 3.9 (9, 25)
Lateral AVPD [mm]22 ± 4.4 (13, 30)21 ± 3.5 (14, 27)
Lateral AVPD /long length [%]23 ± 4.1 (15, 31)24 ± 4.0 (16, 32)

BSA = body surface area; PFR = peak filling rate; E = early; A = active; AVPD = atrioventricular plane descent; SD = standard deviation; CI = confidence interval.

Functional and geometric parameters of the normal right ventricle in the adult, from reference [16] [mean ± SD (95% CI)] BSA = body surface area; PFR = peak filling rate; E = early; A = active; AVPD = atrioventricular plane descent; SD = standard deviation; CI = confidence interval.

Left atrial dimensions and functions in the adult

There is limited consensus in the literature about how to measure left atrial volumes. Therefore depending on the method that is used, SSFP sequences in different views are required. The most common methods to measure left atrial volume are the modified Simpson’s method analogous to the left and right ventricle and the biplane area-length method. Dedicated 3D-modeling software has also been used [17]. For evaluation by applying the Simpson’s method, a stack of cine SSFP images either in the short axis, the horizontal long axis or transverse view is required. For 3-dimensional modeling a stack of short axis images has been used [17]. Evaluation by the biplane area-length method is based on a 2 and 4 chamber view [4]. Left atrial longitudinal and transverse diameters and area have been measured on 2, 3, and 4 chamber cine SSFP images [17]. Generally the left atrial appendage is included as part of the left atrial volume while the pulmonary veins are excluded [4,17,18]. The maximal left atrial volume is achieved during ventricular systole. Using cine images, the maximum volume can be defined as last image before opening of the mitral valve. Accordingly the minimal left atrial volume can be defined as first image after closure of the mitral valve [19]. Body surface area (BSA) has been shown to have a significant independent influence on left atrial volume and most diameters [17]. Per Sievers et al. [20], age is not an independent predictor of left atrial maximal volume [17] nor diameter in normal individuals. Men have a larger maximal left atrial volume compared to women [4,17]. There are three publications for reference values of the left atrium (volume and/or diameter and/or area) based on SSFP imaging with a sufficient sample size [4,17,20] (Table 9). Hudsmith et al. [4] used the biplane area-length method (Figure 7), while Maceira et al. [17] used a 3D modeling technique (Figure 8). Since the results for left atrial maximal volume differ substantially between the two publications, probably based on the different methods, these data are presented separately (Tables 10 and 11, respectively). Maceira et al. provide reference values for maximum left atrial volume, longitudinal, transverse and anteroposterior diameters as well as area (Tables 11, 12 and 13; Figures 8 and 9) [17]. Hudsmith evaluated normal values of maximal and minimal left atrial volume and calculated left atrial ejection fraction and left atrial stroke volume (Table 10) [4]. Sievers et al. provide reference values for left atrial transverse diameters measured on the 2-, 3- and 4-chamber view at ventricular end-systole [20]. Maceira et al. provide both transverse and longitudinal diameters with different 3-chamber methodology than Sievers et al., thus only diameters of Maceira et al. are included (Table 13) [17,20].
Table 9

References, normal left atrial function and dimensions, SSFP technique

First author, year CMR technique N, male: female Age range (yrs)
Sievers, 2005 [20]2, 3 and 4 chamber SSFP; measurement of diameters59:5225-73
Hudsmith, 2005 [4]2 and 4 chamber SSFP; biplane area-length method; atrial appendage included, pulmonary veins excluded63:4521-68
Maceira, 2010 [17]Short axis, 2, 3 and 4 chamber SSFP; 3D modeling and measurement of area and diameters; atrial appendage included, pulmonary veins excluded (for volume analysis)60:6020-80

SSFP = steady-state free precession; yrs = years.

Figure 7

Example of contouring for the biplane area-length method from reference [ 4 ]. The left atrial appendage was included in the atrial volume and the pulmonary veins were excluded.

Figure 8

Contouring of the left and right atrium using a 3D modeling method according to reference [ 17 ].

Table 10

Left atrial volume and function in the adult for the SSFP technique based on the biplane area-length method according to reference [4]

Parameter Men Women
mean SD Lower/ upper limits* mean SD Lower/ upper limits*
Max. LA volume (ml)1033043-163892147-131
Min. LA volume (ml)461418-74411119-63
EF (%)551329-8153935-71
SV (ml)582312-104481518-78

LA = left atrial; Max. = maximal; Min. = minimal; EF = ejection fraction; SV = stroke volume; SD = standard deviation; * = calculated as mean ± 2*SD.

Table 11

Left atrial maximal volume in the adult for the SSFP technique based on 3D modeling methods, according to reference [17]

Parameter Men Women
mean SD Lower/ upper limits* mean SD Lower/ upper limits*
Max. LA volume (ml)7714.947-1076814.938-98
Max. LA volume/BSA (ml/m2)396.726-52406.727-53

LA = left atrial; Max. = maximal; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD.

Table 12

Left atrial maximal area in the adult for the SSFP technique, according to reference [17]

Parameter Men Women
mean SD Lower/ upper limits* mean SD Lower/ upper limits*
Area (cm2) 4ch223.715-29203.713-27
Area/BSA (cm2/ m2) 4ch111.87-15121.88-16
Area (cm2) 2ch214.712-30194.710-28
Area/BSA (cm2/ m2) 2ch112.46-16112.46-16
Area (cm2) 3ch193.612-26173.610-24
Area/BSA (cm2/ m2) 3ch101.86-14101.86-14

LA = left atrial; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; 3ch = 3-chamber view.

Table 13

Left atrial diameter in the adult for the SSFP technique according to reference [17]

Parameter Men Women
mean SD Lower/ upper limits* mean SD Lower/ upper limits*
Longitudinal diameter (cm) 4ch5.90.74.5-7.35.50.74.1-6.9
Longitudinal diameter/BSA (cm/m2) 4ch3.00.42.2-3.83.20.42.4-4.0
Transverse diameter (cm) 4ch4.10.53.1-5.14.10.53.1-5.1
Transverse diameter/BSA (cm/m2) 4ch2.10.31.5-2.72.40.31.8-3.0
Longitudinal diameter (cm) 2ch5.00.73.6-6.44.60.73.2-6.0
Longitudinal diameter/BSA (cm/m2) 2ch2.50.41.7-3.32.70.41.9-3.5
Transverse diameter (cm) 2ch4.60.53.6-5.64.40.53.4-5.4
Transverse diameter/BSA (cm/m2) 2ch2.30.21.9-2.72.60.22.2-3.0
AP diameter (cm) 3ch3.30.52.3-4.33.10.52.1-4.1
AP diameter/BSA (cm/m2) 3ch1.70.31.1-2.31.80.31.2-2.4

BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; 3ch = 3-chamber view; AP = anteroposterior.

Figure 9

Measurement of left atrial area (A2C, A4C, A3C), longitudinal (L2C, L4C), transverse (T2C, T4C) and anteroposterior (APD) diameters on the 2-, 4- and 3-chamber views according to reference [ 17 ].

References, normal left atrial function and dimensions, SSFP technique SSFP = steady-state free precession; yrs = years. Example of contouring for the biplane area-length method from reference [ 4 ]. The left atrial appendage was included in the atrial volume and the pulmonary veins were excluded. Contouring of the left and right atrium using a 3D modeling method according to reference [ 17 ]. Left atrial volume and function in the adult for the SSFP technique based on the biplane area-length method according to reference [4] LA = left atrial; Max. = maximal; Min. = minimal; EF = ejection fraction; SV = stroke volume; SD = standard deviation; * = calculated as mean ± 2*SD. Left atrial maximal volume in the adult for the SSFP technique based on 3D modeling methods, according to reference [17] LA = left atrial; Max. = maximal; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD. Left atrial maximal area in the adult for the SSFP technique, according to reference [17] LA = left atrial; BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; 3ch = 3-chamber view. Left atrial diameter in the adult for the SSFP technique according to reference [17] BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; 3ch = 3-chamber view; AP = anteroposterior. Measurement of left atrial area (A2C, A4C, A3C), longitudinal (L2C, L4C), transverse (T2C, T4C) and anteroposterior (APD) diameters on the 2-, 4- and 3-chamber views according to reference [ 17 ].

Right atrial dimensions and functions in the adult

There is no consensus in the literature regarding acquisition and measurement method for the right atrium. Published methods for right atrial volume include the modified Simpson’s method, the biplane area-length method and 3D-modeling [21,22]. Comparing the Simpsons method and the biplane area length method results in different values for right atrial volume [21]. For Simpson’s method and 3D modeling, a stack of cine SSFP images in the short axis view are analyzed. For the biplane area-length method, a 4-chamber view and/or a right ventricular 2-chamber view are evaluated. Generally the right atrial appendage is included in the right atrial volume while the inferior and superior vena cava are excluded [21,22]. The maximal right atrial volume is achieved during ventricular systole and can be defined as last cine image before opening of the tricuspid valve. The minimal left atrial volume can be defined as first cine image after closure of the tricuspid valve. Maceira et al. demonstrated a significant independent influence of BSA on most RA parameters [22]. There was no influence of age on atrial parameters and no influence of gender on atrial volumes [21,22]. There are two publications of reference values for the right atrium (volume and/or diameter) based on SSFP imaging with a sufficient sample size [21,22] (Table 14). For evaluation of volume, Maceira et al. [22] used a 3D modeling technique (Figure 8) while Sievers et al. [21] applied the Simpsons and the biplane area-length methods, respectively. Due to different methodology, no pooled mean values are provided. Normal values for right atrial volume and function, diameter and area are presented in Tables 15, 16, 17, 18 and 19.
Table 14

References, normal RA function and dimensions, SSFP technique

First author, year CMR technique N, male: female Age range (yrs)
Sievers, 2007 [21]Short axis SSFP and 4 chamber SSFP; Simpsons method and biplane area length method; atrial appendage included, pulmonary veins excluded38:3225-73
Maceira, 2013 [22]Short axis SSFP; 3D modeling; atrial appendage included, pulmonary veins excluded60:6020-80

SSFP = steady-state free precession; yrs = years.

Table 15

Right atrial volume and function in the adult for the SSFP technique based on the Simpson’s method according to reference [21]

Parameter mean SD Lower/ upper limits*
Max. RA volume (ml)1013041-161
Max. RA volume/BSA (ml/ m2)531621-85
Min. RA volume (ml)501912-88
Min. RA volume/BSA (ml/m2)27107-47
SV (ml)501618-82
SV/BSA (ml/m2)2698-44
EF (%)47831-63

RA = right atrial; Max. = maximal; Min. = minimal; SV = stroke volume; EF = ejection fraction; SD = standard deviation; BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented.

Table 16

Right atrial volume and function in the adult for the SSFP technique based on the biplane-area-length method according to reference [21]

Parameter mean SD Lower/ upper limits*
Max. RA volume (ml)1033337-169
Max. RA volume/BSA (ml/ m2)541818-90
Min. RA volume (ml)512011-91
Min. RA volume/BSA (ml/m2)27115-49
SV (ml)521718-86
SV/BSA (ml/m2)2799-45
EF (%)51933-69

RA = left atrial; Max. = maximal; Min. = minimal; SV = stroke volume; EF = ejection fraction; SD = standard deviation; BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented.

Table 17

Right atrial volume in the adult for the SSFP technique based a 3D modeling technique according to reference [22]

Parameter mean SD Lower/ upper limits*
Max. RA volume (ml)1002060-140
Max. RA volume/BSA (ml/ m2)541034-74

RA = left atrial; Max. = maximal; * = calculated as mean ± 2*SD; BSA = body surface area; since no influence of gender was demonstrated, gender specific values are not presented.

Table 18

Right atrial maximal area in the adult for the SSFP technique according to reference [22]

Parameter mean SD Lower/ upper limits*
Area (cm2) 4ch223.814-30
Area/BSA (cm2/ m2) 4ch121.88-16
Area (cm2) 2ch223.9514-30
Area/BSA (cm2/ m2) 2ch122.277-17

BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented.

Table 19

Right atrial diameter in the adult for the SSFP technique according to reference [22]

Parameter mean SD Lower/ upper limits*
Longitudinal diameter (cm) 4ch5.50.584.3-6.7
Longitudinal diameter/BSA (cm/m2) 4ch3.00.322.4-3.6
Transverse diameter (cm) 4ch4.70.553.6-5.8
Transverse diameter/BSA (cm/m2) 4ch2.60.32.0-3.2
Longitudinal diameter (cm) 2ch5.40.54.4-6.4
Longitudinal diameter/BSA (cm/m2) 2ch2.90.32.3-3.5
Transverse diameter (cm) 2ch4.30.72.9-5.7
Transverse diameter/BSA (cm/m2) 2ch2.40.41.6-3.2

BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; since no influence of gender was demonstrated, gender specific values are not presented.

References, normal RA function and dimensions, SSFP technique SSFP = steady-state free precession; yrs = years. Right atrial volume and function in the adult for the SSFP technique based on the Simpson’s method according to reference [21] RA = right atrial; Max. = maximal; Min. = minimal; SV = stroke volume; EF = ejection fraction; SD = standard deviation; BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented. Right atrial volume and function in the adult for the SSFP technique based on the biplane-area-length method according to reference [21] RA = left atrial; Max. = maximal; Min. = minimal; SV = stroke volume; EF = ejection fraction; SD = standard deviation; BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented. Right atrial volume in the adult for the SSFP technique based a 3D modeling technique according to reference [22] RA = left atrial; Max. = maximal; * = calculated as mean ± 2*SD; BSA = body surface area; since no influence of gender was demonstrated, gender specific values are not presented. Right atrial maximal area in the adult for the SSFP technique according to reference [22] BSA = body surface area; * = calculated as mean ± 2*SD; since no influence of gender was demonstrated, gender specific values are not presented. Right atrial diameter in the adult for the SSFP technique according to reference [22] BSA = body surface area; SD = standard deviation; * = calculated as mean ± 2*SD; 4ch = 4-chamber view; 2ch = 2-chamber view; since no influence of gender was demonstrated, gender specific values are not presented.

Left and right ventricular dimensions and function in children

The presentation of normal values in children is different than in the adult population due to continuous changes in body weight and height as a function of age. These changes may also be asymmetrical. Normal data in children is frequently presented in percentiles and/or z-scores. While the use of percentiles is a daily routine for the paediatric radiologist, the use of percentile data might be unfamiliar to the general radiologist. Therefore in the current review, normal values are presented as mean ± standard deviation as well as in percentiles. A linear correlation between ventricular volumes and BSA in children has been reported. Ventricular volumes also vary by gender [23-25]. Ejection fraction remains constant during somatic growth and does not appear to be gender specific [23-25]. Gender differences are more marked in older children, indicating that gender is more important after puberty and in adulthood. Normal values published in studies based on older gradient echo sequences are not comparable to current SSFP techniques [26,27]. Literature values for normative SSFP values have been proposed by three different groups acquired with slightly different methods [23-25] (Table 20). A good agreement between the three studies regarding the dimensions for older children has been demonstrated [25].
Table 20

References, normal left and right ventricular dimensions in children

First author, year CMR technique N, male: female Age range (yrs)
Robbers-Visser, 2009 [23]Short axis SSFP, papillary muscle/ trabeculation excluded from volumes30:30*8-17
Buechel, 2009 [25]Short axis SSFP, papillary muscle/trabeculation included in volumes, separate analysis of papillary muscle mass23:27**7 mo – 18
Sarikouch, 2010 [24]Axial SSFP (in 29 children additional short axis stack), papillary muscle/ trabeculation excluded from volumesTotal: 55:59* Percentiles: 51:48Total: 4–20 Percentiles: 8-20

SSFP = steady-state free precession; yrs = years; mo = month; * = none of the subjects was sedated; ** = 13 subjects were sedated.

References, normal left and right ventricular dimensions in children SSFP = steady-state free precession; yrs = years; mo = month; * = none of the subjects was sedated; ** = 13 subjects were sedated. In the studies of Robbers-Visser et al. and Sarikouch et al., normal values for older children of 8–17 years and 4–20 years, respectively, are presented [23,24], Buechel et al. also include younger children starting with an age of 7 months. In the studies of Robbers-Visser et al. and Sarikouch et al. papillary muscle mass was included as part of LV mass, while Buchel et al. included papillary muscles in the LV cavity and provide separate values for papillary muscle mass. Robbers-Visser et al. and Sarikouch et al. present normal values as mean ± SD for all female and male children and for children of different age groups and also as percentiles. In the study by Buechel et al. data is presented in percentiles only. Due to similar study design and age range, Tables 21 and 22 show pooled mean values for male and female children calculated based on mean values presented by Robbers-Visser et al. and Sarikouch et al. Figures 10,11,12 show normal data in percentiles originally published by Buechel et al.
Table 21

Left ventricular parameters in children, ages 8–17

Parameter Male Female
mean p SD p Lower/ upper limits* mean p SD p Lower/ upper limits*
EDV/BSA [ml/m2]801256-104751055-95
ESV/BSA [ml/m2]28616-4025515-35
SV/BSA [ml/m2]**54936-7250834-66
EF [%]**66556-7663651-75
CI [l/min/ m2]**4.40.852.7-6.13.90.622.7-5.1
Mass/BSA [g/m2]621238-8653935-71

Left ventricular papillary muscle mass included as part of left ventricular mass. Pooled weighted mean values from references [23,24].

meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; CI = cardiac index; SD = standard deviation; ** = from reference [24] (8–15 years) only.

Table 22

Right ventricular parameters in children, ages 8–17

Parameter Male Female
mean p SD p Lower/ upper limits* mean p SD p Lower/ upper limits*
EDV/BSA [ml/m2]841260-10876958-94
ESV/BSA [ml/m2]32718-4627517-37
SV/BSA [ml/m2]**52836-6849735-63
EF [%]**62454-7063455-71
Mass/BSA [g/m2]21511-3118410-26

Right ventricular trabeculation included as part of right ventricular mass. Pooled weighted mean values from references [23,24].

meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp EDV = end-diastolic volume; ESV = end-systolic volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation; ** = from reference [24] only.

Figure 10

Percentiles for left ventricular parameters in children according to reference [ 25 ].

Figure 11

Percentiles for left ventricular papillary muscle mass in children according to reference [ 25 ].

Figure 12

Percentiles for right ventricular parameters in children according to reference [ 25 ].

Left ventricular parameters in children, ages 8–17 Left ventricular papillary muscle mass included as part of left ventricular mass. Pooled weighted mean values from references [23,24]. meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; EDV = end-diastolic volume; ESV = end-systolic volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; CI = cardiac index; SD = standard deviation; ** = from reference [24] (8–15 years) only. Right ventricular parameters in children, ages 8–17 Right ventricular trabeculation included as part of right ventricular mass. Pooled weighted mean values from references [23,24]. meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp EDV = end-diastolic volume; ESV = end-systolic volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation; ** = from reference [24] only. Percentiles for left ventricular parameters in children according to reference [ 25 ]. Percentiles for left ventricular papillary muscle mass in children according to reference [ 25 ]. Percentiles for right ventricular parameters in children according to reference [ 25 ]. Z-values can be calculated as z-value = (measurement – expected mean)/SD by using the values presented in Tables 21 and 22.

Left and right atrial dimensions and function in children

Left and right atrial dimensions and function were evaluated using SSFP technique in a single publication [18], (Table 23). Measurements were obtained on a stack of transverse cine SSFP images with a slice thickness between 5 and 6 mm without interslice gap [18].
Table 23

Reference, normal left and right atrial dimensions in children

First author, year CMR technique N, male: female Age range (yrs)
Sarikouch, 2011 [18]Axial SSFP; pulmonary veins, SVC, IVC and coronary sinus excluded, atrial appendages included from/in the left and right atrial volume, respectively56:594.4-20.3

SSFP = steady-state free precession; SVC = superior vena cava; IVC inferior vena cava; yrs = years.

Reference, normal left and right atrial dimensions in children SSFP = steady-state free precession; SVC = superior vena cava; IVC inferior vena cava; yrs = years. In that study, the pulmonary veins, the superior and inferior vena cava and the coronary sinus were excluded from the left and right atrial volume, respectively, while the atrial appendages were included in the volume of the respective atrium. The maximal atrial volume was measured at ventricular end-systole and the minimal atrial volume at ventricular end-diastole. Left and right atrial volumes show an increase with age with a plateau after the age of 14 for girls only. Absolute and indexed volumes have been shown to be significantly greater for boys compared to girls (except for the indexed maximal volumes for both atria) [18]. Sarikouch et al. evaluated atrial parameters of 115 healthy children (Table 23) [18] using SSFP imaging. Since the standard deviation is large for each parameter, lower and upper limits were not calculated (Tables 24 and 25). Theoretically calculation of lower limits by mean – (2*SD) would result in negative lower limits for certain parameters.
Table 24

Left atrial parameters in children, ages 4–20 according to reference [18]

Male Female
Parameter mean SD mean SD
Vol. max. [ml]71305920
Vol. max./BSA [ml/m2]4710449
Vol. min. [ml]3315269
Vol. min./BSA [ml/m2]225194
SV [ml]38163312
EF [%]546566

Vol. max. = maximal atrial volume; Vol. min. = minimal atrial volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation.

Table 25

Right atrial parameters in children, ages 4–20 according to reference [18]

Male Female
Parameter mean SD mean SD
Vol. max. [ml]89437125
Vol. max./BSA [ml/m2]58165312
Vol. min. [ml]42213113
Vol. min./BSA [ml/m2]278236
SV [ml]47244015
EF [%]537568

Vol. max. = maximal atrial volume; Vol. min. = minimal atrial volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation.

Left atrial parameters in children, ages 4–20 according to reference [18] Vol. max. = maximal atrial volume; Vol. min. = minimal atrial volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation. Right atrial parameters in children, ages 4–20 according to reference [18] Vol. max. = maximal atrial volume; Vol. min. = minimal atrial volume; BSA = body surface area; SV = stroke volume; EF = ejection fraction; SD = standard deviation.

Normal left ventricular myocardial thickness

Normal values of left ventricular myocardial thickness (LVMT) have been shown to vary by type of pulse sequence (FGRE versus SSFP) [3,28]. For the purposes of this review, only SSFP normal values are shown. Measures of LVMT vary by the plane of acquisition (short axis versus long axis) [29]. Measurements obtained on long axis images at the basal and mid-cavity level have been shown to be significantly greater compared to measurements on corresponding short axis images, whereas measurements obtained at the apical level of long axis images are significantly lower compared to short axis images. In recent publications, papillary muscles and trabeculations were excluded from measurements of left ventricular myocardial thickness [29,30]. LVMT is greater in men than women [29,30]. There are also small differences in LVMT in relationship to ethnicity and body size, but these variations are not likely to have clinical significance [29]. Regarding age, one study of 120 healthy volunteers age 20–80 years reported an increase in myocardial thickness with age—starting after the fourth decade [30]. In the study by Kawel el al. of 300 normal individuals without hypertension, smoking history or diabetes, there was no statistically significant difference in LVMT with age [29]. There are two publications of a systematic analysis of left ventricular myocardial thickness based on SSFP imaging at 1.5T [29,30]. In the study by Dawson et al., measurements were obtained on short axis images only. Kawel et al. published normal values of LVMT for long and short axis imaging (Tables 26, 27 and 28).
Table 26

References, normal left ventricular myocardial thickness in adults

First author, year CMR technique N, male: female Age range (yrs)
Dawson, 2011 [30]Short axis SSFP, papillary muscle/ trabeculation excluded from LVMT60:6020-80
Kawel, 2012 [29]Short and long axis SSFP, papillary muscle/ trabeculation excluded from LVMT131:16954-91

SSFP = steady-state free precession; yrs = years; LVMT = left ventricular myocardial thickness.

Table 27

Normal left ventricular myocardial thickness in mm measured on long axis images for men and women according to [29]

Men Women
Level Region mean SD Lower/upper limits* mean SD Lower/upper limits*
basalanterior8.21.35.6-10.87.01.14.8-9.2
inferior8.21.35.6-10.86.71.14.5-8.9
septal9.11.36.5-11.77.31.15.1-9.5
lateral7.61.35.0-10.26.01.13.8-8.2
mean 8.31.06.3-10.36.80.95.0-8.6
mid-cavityanterior6.01.33.4-8.64.91.12.7-7.1
inferior7.71.35.1-10.36.51.14.3-8.7
septal8.31.35.7-10.96.81.14.6-9.0
lateral6.61.34.0-9.25.31.13.1-7.5
mean 7.21.05.2-9.25.90.94.1-7.7
apicalanterior5.11.32.5-7.74.21.12.0-6.4
inferior5.81.33.2-8.45.01.12.8-7.2
septal5.81.33.2-8.45.01.12.8-7.2
lateral5.51.32.9-8.14.61.12.4-6.8
mean 5.61.03.6-7.64.70.92.9-6.5

* = calculated as mean ± (2*SD).

Table 28

Normal left ventricular myocardial thickness in mm measured on short axis images for men and women

Men Women
Level Segment mean p SD p Lower/upper limits* mean p SD p Lower/upper limits*
basal18.21.16.0-10.46.71.04.7-8.7
29.61.17.4-11.87.91.05.9-9.9
39.21.17.0-11.47.51.05.5-9.5
48.11.15.9-10.36.61.04.6-8.6
57.31.15.1-9.56.01.04.0-8.0
67.41.15.2-9.66.10.94.3-7.9
mid-cavity76.71.14.5-8.95.71.03.7-7.7
87.71.15.5-9.96.41.04.4-8.4
98.21.16.0-10.46.91.04.9-8.9
107.01.14.8-9.25.91.03.9-7.9
116.21.14.0-8.45.20.93.4-7.0
126.41.14.2-8.65.41.03.4-7.4
apical136.71.14.5-8.96.41.04.4-8.4
147.31.15.1-9.56.31.04.3-8.3
156.21.14.0-8.45.41.03.4-7.4
166.31.14.1-8.55.91.03.9-7.9

Pooled weighted mean values from references [29,30].

meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; Segments: 1 = basal anterior, 2 = basal anteroseptal, 3 = basal inferoseptal, 4 = basal inferior, 5 = basal inferolateral, 6 = basal anterolateral, 7 = mid anterior, 8 = mid anteroseptal, 9 = mid inferoseptal, 10 = mid inferior, 11 = mid inferolateral, 12 = mid anterolateral, 13 = apical anterior, 14 = apical septal, 15 = apical inferior, 16 = apical lateral.

References, normal left ventricular myocardial thickness in adults SSFP = steady-state free precession; yrs = years; LVMT = left ventricular myocardial thickness. Normal left ventricular myocardial thickness in mm measured on long axis images for men and women according to [29] * = calculated as mean ± (2*SD). Normal left ventricular myocardial thickness in mm measured on short axis images for men and women Pooled weighted mean values from references [29,30]. meanp = pooled weighted mean; SDp = pooled standard deviation; * = calculated as meanp ± 2*SDp; Segments: 1 = basal anterior, 2 = basal anteroseptal, 3 = basal inferoseptal, 4 = basal inferior, 5 = basal inferolateral, 6 = basal anterolateral, 7 = mid anterior, 8 = mid anteroseptal, 9 = mid inferoseptal, 10 = mid inferior, 11 = mid inferolateral, 12 = mid anterolateral, 13 = apical anterior, 14 = apical septal, 15 = apical inferior, 16 = apical lateral.

Cardiac valves and quantification of flow

Prospectively and retrospectively ECG- gated phase contrast (PC) CMR sequences are available on most CMR machines. Prospectively-gated sequences use arrhythmia rejection and may be performed in a breath hold. Retrospectively gated techniques are mainly performed during free-breathing, often with higher spatial and temporal resolution compared to the breath hold techniques [31]. 4D PC flow quantification techniques show initial promising results, but 2D PC flow techniques are currently used in the daily clinical routine [32]. Apart from PC-CMR, valve planimetry—using ECG-gated SSFP CMR— can also be used to estimate stenosis or insufficiencies with good correlation to echocardiographic measurements [33]. Measurements of flow are most precise when a) the imaging plane is positioned perpendicular to the vessel of interest and b) the velocity encoded gradient echo (Venc) is encoded in a through plane direction [34]. The slice thickness should be <7 mm to minimize partial volume effects. Compared to aortic or pulmonary flow evaluation, quantification of mitral or tricuspid valves is more challenging using PC-CMR due to substantial through plane motion during the cardiac cycle [35].

Flow encoding velocity (Venc)

The Venc should be chosen close to the maximum expected flow velocity of the examined vessel for precise measurements. Setting the Venc below the peak velocity results in aliasing. For the normal aorta and main pulmonary artery, maximum velocities do not exceed 150 and 90 cm/sec, respectively. Adequate temporal resolution is necessary to avoid temporal flow averaging, especially for the evaluation of short, fast, and turbulent jets within a vessel (e.g. aortic stenosis). For the clinical routine, 25–30 msec temporal resolution is usually sufficient. The minimum required spatial resolution should be less than one third of the vessel diameter to avoid partial volume effects with the adjacent vessel wall and surrounding stationary tissues for small arteries [34]. For data analysis, dedicated flow software should be used. Most of the currently available flow software tools offer semi-automatic vessel contouring, which needs to be carefully checked by the examiner. The modified Bernoulli equation (∆P = 4 × Vmax2) is commonly used for calculation of pressure gradients using PC-CMR across the pulmonary or aortic valve [36,37]. It has to be considered that velocity measurements of a stenotic lesion with high jet velocities might be inaccurate due to partial volume effects in case of a small jet width and also the limited temporal resolution compared to the high velocity of the jet. Measurements are further affected by signal loss due to the high velocity that may lead to phase shift errors and dephasing. Misalignement of the slice relative to the direction of the jet may lead to an underestimation of the peak velocity [38]. To our knowledge, data of the association between normal values of flow and valve planimetry with demographic parameters has not been previously published. There is good agreement between PC-CMR, SSFP CMR planimetry, and echocardiography measurements, American Heart Association (AHA) criteria for grading valve stenosis or insufficiency is suggested [33,39,40] (Table 29). To date, there is no publication of normal reference values of flow and valve planimetry based on CMR measurements.
Table 29

Grading valve disease adapted from echocardiography [39,41]

Valve disease Indicator Mild Moderate Severe
Aortic stenosisPeak velocity [m/s]<33-4>4
Orifice area [cm2]>1.51.0-1.5<1.0
Orifice area /BSA [cm2/m2]<0.6
Aortic regurgitationRegurgitant volume [ml/beat]<3030-59≥60
Regurgitant fraction [%]<3030-49≥50
Regurgitant orifice area [cm2]<0.100.10-0.29≥0.30
Mitral stenosisPeak velocity [m/s]<1.21.2-2.2>2.2
Orifice area [cm2]>1.51.0-1.5<1.0
Mitral regurgitationRegurgitant volume [ml/beat]<3030-59≥60
Regurgitant fraction [%]<3030-49≥50
Regurgitant orifice area [cm2]<0.200.20-0.39≥0.40
Pulmonary stenosisPeak velocity [m/s]<33-4>4
Orifice area [cm2]<1
Pulmonary regurgitationRegurgitant volume [ml/beat]<3030-40>40
Regurgitant fraction [%]<2520-35>35
Tricuspid stenosisOrifice area [cm2]<1.0
Grading valve disease adapted from echocardiography [39,41] Mitral valve flow velocities and deceleration time as for determination of diastolic left ventricular function measured by CMR showed a good correlation with measurements derived by transthoracic echocardiography but with a systematic underestimation [42] (Table 30).
Table 30

Mitral valve flow for determination of diastolic left ventricular function according to reference [43]

Parameter Normal Type 1 (Impaired relaxation) Type 2 (Pseudonormal) Type 3 (Restrictive, partially reversible) Type 3 (Restrictive, fixed)
MDT (ms)150-220IncreasedNormalDecreasedDecreased
E/A ratio1-2<11-2>2>2

MDT = mitral deceleration time; E/A ratio = ratio of the mitral early (E) and atrial (A) components of the mitral inflow velocity profile.

Mitral valve flow for determination of diastolic left ventricular function according to reference [43] MDT = mitral deceleration time; E/A ratio = ratio of the mitral early (E) and atrial (A) components of the mitral inflow velocity profile.

Normal aortic dimensions in the adult

Three- dimensional contrast enhanced MR Angiography (MRA) has gained broad acceptance and is widely used for assessment and follow-up of thoracic aortic diameter in clinical setting. The multi-planar reformation of MRA images leads to an accurate measurement perpendicular to the lumen of the vessel. However, the need of a contrast injection is a limitation for the use of this technique in patients who need multiple follow up examinations and in population based study settings [44]. Alternatively non-contrast techniques such as ECG gated non contrast 3D (2D) balanced steady state free precession (SSFP) CMR can be applied. The modulus image of phase contrast CMR has also been used to measure diameters of the aorta [45]. 2D Black blood CMR is used for a more detailed aortic wall assessment. In 2D acquisitions, the imaging plane needs to be acquired correctly at the time of the scan; thus any alterations in the imaging plane will result in a higher variability and lower accuracy of measurements. Another limitation for ascending thoracic aorta diameter measurement is the through plane motion during the cardiac cycle which can be minimized with ECG gating [44]. Potthast and colleagues compared the diameter of the ascending aorta obtained by different CMR sequences to ECG-triggered CT angiography as the gold standard and reported that ECG gated navigator triggered 3D SSFP sequence showed the best agreement with CT [44]. It is important to indentify the anatomic locations of diameter measurements of the thoracic aorta. In the studies cited here, measurements were obtained at the following anatomic locations: 1. aortic root cusp-commissure and cusp-cusp measurements; 2. aortic valve annulus; 3. aortic sinus; 4. sinotubular junction; 5. ascending aorta and proximal descending aorta: measurements at the level of the right pulmonary artery; 6. abdominal aorta: 12 cm distal to the pulmonary artery (Figure 13).
Figure 13

The anatomic locations of aorta measurements: A. aortic valve annulus; B. aortic sinus; C. sinotubular junction; D. ascending aorta and proximal descending aorta; E. abdominal aorta.

The anatomic locations of aorta measurements: A. aortic valve annulus; B. aortic sinus; C. sinotubular junction; D. ascending aorta and proximal descending aorta; E. abdominal aorta. The sagittal oblique view of the left ventricular outflow tract was used for measuring diameter at the level of the aortic annulus, the aortic sinus, and the sinotubular junction. Axial cross sectional images at predefined anatomic levels were used for measuring the ascending and descending aorta [46] as well as cusp-commissure and cusp-cusp diameters at the level of the aortic sinus [47] (Figures 13 and 14). There is no definite convention about measuring the luminal or outer to outer diameter of the aorta. Usually, measurement technique depends on the resolution and characteristics of the available MRI sequence. In the tables below, the method is specified.
Figure 14

Cusp-commissure (continuous lines) and cusp-cusp (dashed-lines) measurements at the level of the aortic sinus.

Cusp-commissure (continuous lines) and cusp-cusp (dashed-lines) measurements at the level of the aortic sinus. Age, gender and body size are major determinants of physiologic variation in aortic size. In the Multi-Ethnic Study of Atherosclerosis, which included participants from four different ethnicities, the race/ethnicity were not clinically significant determinants of ascending aorta diameter [45]. Aortic diameter and ascending aorta length increase with age, leading to decreased curvature of the aortic arch [48,49]. The association of age with aortic diameter was more marked in the ascending aorta compared to the descending thoracic and abdominal aorta, respectively [50,51]. Additionally, the descending aorta did not demonstrate age associated lengthening [49]. Studies with normal values of aortic diameters including 50 or more subjects for both men and women and a range of ages (due to the age dependence of aortic diameters) have been included in this review (Tables 31, 32, 33, 34 and 35). There are three major publications regarding MR-based measurements of the thoracic aorta in adults: Davis et al. determined aortic diameter at three levels (ascending aorta, proximal descending aorta and abdominal aorta) by calculating the luminal diameter based on measurements of the cross sectional area obtained on cine SSFP images [46]. In the original publication normal age and gender specific absolute and indexed (for BSA) values are presented in a graph and absolute numbers are presented for different weight categories (Table 32).
Table 31

References, normal aortic dimensions in adults

First author, year CMR technique N, male: female Age range (yrs)
Davis, 2014 [46]SSFP; luminal diameter of thoracic and abdominal aorta208: 23919-70
Turkbey, 2013 [45]Phase contrast (magnitude image); luminal diameter of ascending thoracic aorta770:84245-84
Burman, 2008 [47]SSFP; luminal diameter of aortic root60:6020-80

SSFP = steady-state free precession; yrs = years.

Table 32

Normal values (in mm) of the thoracic and abdominal aortic luminal diameters for men and women of different BMI categories measured at diastole (mean[±2SD]) according to [46]

Men Women
Level Normal weight Overweight Obese Normal weight Overweight Obese
Aortic annulus 23.9 (18.6-29.2)24.3 (18.9-29.7)25.6 (20.4-30.8)20.6 (17.4-23.8)21.7 (18.4-25.0)21.5 (17.2-25.8)
Aortic sinus 31.9 (24.3-39.5)32.8 (25.2-40.4)33.3 (24.3-42.3)27.5 (21.9-33.1)28.0 (21.8-34.2)27.5 (21.3-33.7)
Sinotubular junction 24.4 (18.2- 30.6)25.7 (16.7- 34.7)26.2 (18.9- 33.5)21.6 (16.6- 26.6)22.3 (17.0- 27.6)22.1 (15.9- 28.3)
Ascending aorta 26.0 (18.7-33.3)27.4 (18.9-35.9)28.5 (23.1-33.9)24.7 (17.8-31.6)26.5 (19.3-33.7)26.6 (18.8-34.4)
Prox. desc. aorta 20.1 (14.7-25.5)20.9 (15.6-26.2)22.2 (16.3-28.1)18.5 (14.6-22.4)19.2 (14.8-23.6)19.6 (16.5-23.2)
Abdominal aorta * 17.1 (12.0-22.2)17.9 (12.8-23.0)18.8 (14.4-23.2)16.0 (12.1-19.9)16.3 (12.3-20.3)17.4 (13.9-20.9)

normal weight = BMI <25 kg/m2; overweight = BMI 25–29.9 kg/m2; obese = BMI >30 kg/m2; prox. desc. aorta = proximal descending aorta; * = abdominal aorta measured 12 cm distal to the pulmonary artery.

Table 33

Absolute and BSA indexed normal values of ascending aortic luminal diameter for men and women of different age categories (median [5th-95th percentile]) measured on phase contrast images according to [45]

Age (years) Men Women
Absolute values (mm)
45-54 31.6 (27.2-37.3)28.8 (24.6-34.4)
55-64 32.8 (28.1-40.7)30.1 (25.7-36.4)
65-74 34.2 (28.7-41.0)30.6 (26.1-36.3)
75-84 34.7 (28.6-40.8)31.1 (26.8-37.1)
Values indexed to BSA (mm/m 2 )
45-54 15.9 (13.3-19.5)16.7 (13.5-20.7)
55-64 16.8 (13.6-21.1)17.6 (14.8-22.1)
65-74 17.8 (14.2-21.8)18.1 (14.5-22.1)
75-84 18.6 (15.2-22.6)19.7 (15.3-28.2)

BSA = body surface area.

Table 34

Absolute and indexed (to BSA) normal values of aortic root cusp-commissure measurements for men and women of different age categories measured at systole and diastole (mean ± SD [lower/upper limits calculated as mean ± 2SD]) according to [47]

Men Women
Age (years) systolic diastolic systolic diastolic
Absolute values (mm)
20-29 32.6 ± 3.5 (26–40)30.4 ± 3.3 (24–37)28.6 ± 3.9 (21–36)26.3 ± 3.9 (19–34)
30-39 32.0 ± 3.3 (25–39)29.7 ± 3.5 (23–37)28.5 ± 2.8 (23–34)26.8 ± 2.8 (21–32)
40-49 33.3 ± 2.1 (29–38)31.6 ± 1.6 (28–35)31.7 ± 2.8 (26–37)30.0 ± 2.1 (26–34)
50-59 33.9 ± 5.1 (24–44)32.7 ± 4.8 (23–42)29.5 ± 2.0 (26–34)28.4 ± 1.8 (25–32)
60-69 34.6 ± 2.5 (30–40)33.5 ± 2.3 (29–38)30.5 ± 1.9 (27–34)29.5 ± 2.0 (26–34)
70-79 35.1 ± 3.1 (29–41)33.9 ± 3.0 (28–40)30.7 ± 1.3 (28–33)29.6 ± 1.4 (27–32)
all 33.6 ± 3.4 (27–40)32.0 ± 3.5 (25–39)29.9 ± 2.7 (25–35)28.4 ± 2.8 (23–34)
Values indexed to BSA (mm/m 2 )
20-29 16.8 ± 1.6 (14–20)15.6 ± 1.7 (12–19)16.7 ± 1.9 (13–21)15.3 ± 2.0 (11–19)
30-39 16.3 ± 1.6 (13–20)15.1 ± 1.6 (12–18)17.5 ± 1.3 (15–20)16.4 ± 1.3 (14–19)
40-49 16.1 ± 1.1 (14–18)15.3 ± 1.0 (13–17)17.8 ± 2.6 (13–23)16.8 ± 2.3 (12–21)
50-59 17.2 ± 2.1 (13–21)16.6 ± 1.9 (13–20)17.8 ± 1.4 (15–21)17.2 ± 1.4 (14–20)
60-69 17.7 ± 1.8 (14–21)17.2 ± 1.7 (14–21)17.7 ± 1.5 (15–21)17.1 ± 1.4 (14–20)
70-79 18.0 ± 1.2 (16–20)17.4 ± 1.2 (15–20)18.5 ± 0.9 (17–20)17.8 ± 0.9 (16–20)
all 17.0 ± 1.7 (14–20)16.2 ± 1.8 (13–20)17.7 ± 1.7 (14–21)16.8 ± 1.7 (13–20)

BSA = body surface area.

Table 35

Absolute and indexed (to BSA) normal values of aortic root cusp-cusp measurements for men and women of different age categories measured at systole and diastole (mean ± SD [lower-upper limits calculated as mean ± 2*SD]) according to [47]

Men Women
Age (years) systolic diastolic systolic diastolic
Absolute values (mm)
20-29 34.4 ± 4.2 (26–43)32.8 ± 3.8 (25–40)30.2 ± 4.7 (21–40)28.4 ± 4.7 (19–38)
30-39 33.8 ± 3.8 (26–41)32.0 ± 3.9 (24–40)30.0 ± 3.1 (24–36)28.7 ± 3.0 (23–35)
40-49 36.0 ± 2.7 (31–41)34.1 ± 2.3 (30–39)33.9 ± 2.5 (29–39)32.8 ± 2.5 (28–38)
50-59 36.3 ± 5.9 (25–48)35.2 ± 5.7 (24–47)31.4 ± 2.5 (26–36)30.6 ± 2.6 (25–36)
60-69 37.4 ± 2.9 (32–43)36.2 ± 2.5 (31–41)32.8 ± 2.3 (28–37)32.0 ± 2.2 (28–36)
70-79 37.8 ± 3.9 (30–46)37.0 ± 3.5 (30–44)32.9 ± 1.7 (30–36)32.0 ± 1.6 (29–35)
all 36.0 ± 4.1 (28–44)34.6 ± 4.0 (27–43)31.9 ± 3.2 (26–38)30.7 ± 3.3 (24–37)
Values indexed to BSA (mm/m 2 )
20-29 17.7 ± 1.9 (14–22)16.9 ± 1.9 (13–21)17.6 ± 2.3 (13–22)16.6 ± 2.3 (12–21)
30-39 17.2 ± 2.0 (13–21)16.2 ± 1.9 (12–20)18.4 ± 1.4 (16–21)17.6 ± 1.3 (15–20)
40-49 17.4 ± 1.4 (15–20)16.5 ± 1.3 (14–19)19.0 ± 2.7 (14–24)18.4 ± 2.5 (13–23)
50-59 18.5 ± 2.4 (14–23)17.9 ± 2.3 (13–23)18.9 ± 1.7 (16–22)18.5 ± 1.8 (15–22)
60-69 19.2 ± 2.2 (15–24)18.6 ± 2.0 (15–23)19.0 ± 1.8 (15–23)18.6 ± 1.6 (15–22)
70-79 19.4 ± 1.4 (17–22)19.0 ± 1.3 (16–22)19.8 ± 1.0 (18–22)19.3 ± 1.0 (17–21)
all 17.6 ± 2.0 (14–22)17.5 ± 2.0 (14–22)18.8 ± 1.9 (15–23)18.1 ± 2.0 (14–22)

BSA = body surface area.

References, normal aortic dimensions in adults SSFP = steady-state free precession; yrs = years. Normal values (in mm) of the thoracic and abdominal aortic luminal diameters for men and women of different BMI categories measured at diastole (mean[±2SD]) according to [46] normal weight = BMI <25 kg/m2; overweight = BMI 25–29.9 kg/m2; obese = BMI >30 kg/m2; prox. desc. aorta = proximal descending aorta; * = abdominal aorta measured 12 cm distal to the pulmonary artery. Absolute and BSA indexed normal values of ascending aortic luminal diameter for men and women of different age categories (median [5th-95th percentile]) measured on phase contrast images according to [45] BSA = body surface area. Absolute and indexed (to BSA) normal values of aortic root cusp-commissure measurements for men and women of different age categories measured at systole and diastole (mean ± SD [lower/upper limits calculated as mean ± 2SD]) according to [47] BSA = body surface area. Absolute and indexed (to BSA) normal values of aortic root cusp-cusp measurements for men and women of different age categories measured at systole and diastole (mean ± SD [lower-upper limits calculated as mean ± 2*SD]) according to [47] BSA = body surface area. Turkbey et al. measured the luminal diameter of the ascending aorta on magnitude images of a phase contrast sequence in a large number of healthy subjects [45] (Table 33). Burmann et al. performed detailed measurements of the aortic root including cusp-commissure and cusp-cusp measurements at diastole and systole on cine SSFP images [47] (Tables 34 and 35).

Normal aortic dimensions in children

There is no consensus regarding the sequence type used to measure aortic diameters and areas. In the three major publications (Table 36) measurements were obtained on 3 dimensional contrast enhanced MR angiography [52], gradient echo images [53] and phase contrast cine images [54].
Table 36

References, normal aortic dimensions in children

First author, year CMR technique N, male: female Age range (yrs)
Kaiser, 2008 [52]Contrast enhanced 3D MR angiography; shortest diameter30:232-20
Voges, 2012 [53]Cine GRE; measurements obtained at maximal distension of the aorta30:412.3-28.3
Kutty, 2012 [54]Cine phase contrast CMR; measurements obtained at systole55:504.4-20.4

GRE = gradient echo; 3D = 3-dimensional; yrs = years.

References, normal aortic dimensions in children GRE = gradient echo; 3D = 3-dimensional; yrs = years. In order to reduce error in measurement, care has to be taken to obtain or reconstruct cross sectional images that are true perpendicular instead of oblique to the course of the vessel. Kaiser et al. demonstrated that aortic diameter measurements show a slight variation with measurement plane with a mean difference between measurements on cross-sectional and longitudinal images of 0.16 mm and a coefficient of variability of 2.1% [52]. Kutty et al. indicate that in their study the outer diameter of the vessel was measured [54] while Kaiser et al. and Voges et al. do not mention details in this respect [52,53]. Aortic diameters vary by BSA [52,54] but do not show gender differences [53,54]. Aortic area did also not show any gender differences [53]. There are three publications of a systematic evaluation of aortic dimensions (diameter and/or area) in children that vary by CMR-technique, measurement technique and data presentation (Table 36): In the study by Kaiser et al. aortic diameter was measured as the shortest diameter passing the center of the vessel at 9 levels of the thoracic aorta on reconstructed cross-sectional images of a contrast enhanced 3 dimensional MR angiography [52]. In the original publication data is presented as median and range as well as percentiles, z-scores and regression models incorporating BSA. Voges et al. present measurements obtained at four levels of the thoracic aorta obtained on cine GRE images at maximal aortic distension as mean ± standard deviation and as percentiles [53]. In the study by Kutty et al. aortic diameter and area was measured 1-2 cm distal to the sinotubular junction at systole on phase contrast cine images [54]. Data is presented as mean ± standard deviation, regression equation and z-scores. In this review we present regression equations of normal aortic diameters measured at 9 different sites according to [52] (Table 37, Figure 15) and of normal area of the ascending aorta according to [54] (Table 38). Further reference percentiles of aortic area measured at 4 different locations obtained on cine GRE images are presented in Figure 16 according to [53]. The z-scores for each aortic diameter (D) can be calculated with the following equation:
Table 37

Normal aortic diameters (in mm) measured on reconstructed cross-sectional images of a contrast enhanced 3D-MR angiography according to reference [52]

Site Predicted diameter SD of residuals
Aortic sinus0.57 + 19.37*BSA0.5 2.38
Sinotubular junction−0.03 + 16.91*BSA0.5 1.92
Ascending aorta−1.33 + 18.6*BSA0.5 1.99
Proximal to the origin of the brachiocephalic artery−3.38 + 20.07*BSA0.5 1.69
First transverse segment−3.52 + 18.66*BSA0.5 1.63
Second transverse segment−2.63 + 16.5*BSA0.5 1.31
Isthmic region−3.37 + 16.52*BSA0.5 1.46
Descending aorta−1.12 + 14.42*BSA0.5 1.64
Thoracoabdominal aorta at the level of the diaphragm1.27 + 9.89*BSA0.5 1.34

BSA = body surface area; SD = standard deviation.

Figure 15

Sites of measurement. AS = aortic sinus; STJ = sinotubular junction; AA = ascending aorta; BCA = proximal to the origin of the brachiocephalic artery; T1 = first transverse segment; T2 = second transverse segment; IR = isthmic region; DA = descending aorta; D = thoracoabdominal aorta at the level of the diaphragm.

Table 38

Normal aortic area (in cm ) measured 1-2 cm distal to the sinotubular junction at systole on phase contrast cine images according to reference [54]

Site Predicted diameter
Ascending aorta−0.0386 + 2.913*BSA

BSA = body surface area.

Figure 16

Reference percentiles for aortic areas measured at four different sites (ascending aorta [a], aortic arch [b], aortic isthmus [c] and descending aorta above the diaphragm [d]) on cine GRE images at maximal aortic distension according to reference [ 53 ].

Normal aortic diameters (in mm) measured on reconstructed cross-sectional images of a contrast enhanced 3D-MR angiography according to reference [52] BSA = body surface area; SD = standard deviation. Sites of measurement. AS = aortic sinus; STJ = sinotubular junction; AA = ascending aorta; BCA = proximal to the origin of the brachiocephalic artery; T1 = first transverse segment; T2 = second transverse segment; IR = isthmic region; DA = descending aorta; D = thoracoabdominal aorta at the level of the diaphragm. Normal aortic area (in cm ) measured 1-2 cm distal to the sinotubular junction at systole on phase contrast cine images according to reference [54] BSA = body surface area. Reference percentiles for aortic areas measured at four different sites (ascending aorta [a], aortic arch [b], aortic isthmus [c] and descending aorta above the diaphragm [d]) on cine GRE images at maximal aortic distension according to reference [ 53 ]. on the base of the data provided in Table 37. Due to the differences in acquisition and measurement technique as well as presentation of results, weighted mean values were not calculated.

Normal aortic distensibility/ pulse wave velocity in adults

Pulse wave velocity (PWV) calculations using a velocity-encoded CMR with phase contrast sequences allow accurate assessment of aortic systolic flow wave and the blood flow velocity. The sequence should be acquired at the level of the bifurcation of the pulmonary trunk, perpendicular to both, the ascending and descending aorta. The distance between two aortic locations (aortic length) can be estimated from axial and coronal cine breath hold SSFP sequences covering the whole aortic arch [55]. Alternatively, sagittal oblique views of the aortic arch can be acquired using a black blood spin echo sequence [51]. Another measurement method of aortic stiffness is aortic distensibility. The cross sectional aortic area at different phases of the cardiac cycle is measured using ECG-gated SSFP cine imaging to assess aortic distensibility by CMR. Modulus images of cine phase contrast CMR can be used as well [56]. PWV is the most validated method to quantify arterial stiffness using CMR. PWV is calculated by measuring the pulse transit time of the flow curves (Δt) and the distance (D) between the ascending and descending aortic locations of the phase contrast acquisition [51]: Aortic PWV = D/ Δt (Figure 17).
Figure 17

Measurement of pulse wave velocity according to reference [ 53 ] . Δx = length of the centerline between the sites of flow measurement in the ascending and descending aorta (A); Δt = time delay between the flow curves obtained in the descending aorta relative to the flow curve obtained in the ascending aorta calculated between the midpoint of the systolic up slope tails on the flow versus time curves of the ascending aorta (ta1) and the descending aorta (ta2) (B).

Measurement of pulse wave velocity according to reference [ 53 ] . Δx = length of the centerline between the sites of flow measurement in the ascending and descending aorta (A); Δt = time delay between the flow curves obtained in the descending aorta relative to the flow curve obtained in the ascending aorta calculated between the midpoint of the systolic up slope tails on the flow versus time curves of the ascending aorta (ta1) and the descending aorta (ta2) (B). PWV increases with stiffening of arteries since the stiffened artery conducts the pulse wave faster compared to more distensible arteries. Aortic distensibility is calculated with the fallowing formula after measuring the minimum and maximum aortic cross sectional area [57]: Aortic Distensibility = (minimum area- maximum area)/ (minimum area x ΔP x 1000) where ΔP is the pulse pressure in mmHg. Greater ascending aorta diameter and changes in aortic arch geometry by aging was significantly associated with increased regional stiffness of the aorta, especially the ascending portion. The relationship of age with measures of aortic stiffness is non –linear and the decrease of aortic distensibility is steeper before the fifth decade of life [51]. Males have stiffer aortas compared to females [58]. Two publications reported normal values of pulse wave velocity and aortic distensibility (Tables 39, 40 and 41).
Table 39

References, ascending and descending thoracic aorta distensibility, aortic arch pulse wave velocity

First author, year CMR technique N, male: female Age range (yrs)
Redheuil, 2010 [51]Phase contrast CMR and gradient echo cine54:5720-84
Rose, 2010 [58]SSFP13:1323-61

yrs = years; SSFP = steady-state free precession.

Table 40

Normal values of ascending and descending thoracic aorta distensibility and aortic arch pulse wave velocity by age categories (mean ± SD) according to [51]

Age categories (years)
20-29 30-39 40-49 50-59 60-69 ≥70
Ascending aortic distensibility (kPa −1 . 10 −3 ) 74 ± 2361 ± 2331 ± 1818 ± 712 ± 710 ± 6
Descending aortic distensibility (kPa −1 . 10 −3 ) 72 ± 1870 ± 2438 ± 1729 ± 1318 ± 817 ± 6
Aortic arch PWV (m/s) 3.5 ± 0.53.9 ± 1.15.6 ± 1.47.2 ± 2.39.7 ± 2.911.1 ± 4.6

PWV = Pulse wave velocity.

Table 41

Normal values of ascending and descending thoracic aorta distensibility (in 10   mmHg ) by gender (mean ± SD) according to [58]

Men Women
Ascending Aorta 6.1 ± 2.58.6 ± 2.7
Descending Aorta 5.1 ± 2.47.2 ± 1.6
References, ascending and descending thoracic aorta distensibility, aortic arch pulse wave velocity yrs = years; SSFP = steady-state free precession. Normal values of ascending and descending thoracic aorta distensibility and aortic arch pulse wave velocity by age categories (mean ± SD) according to [51] PWV = Pulse wave velocity. Normal values of ascending and descending thoracic aorta distensibility (in 10   mmHg ) by gender (mean ± SD) according to [58]

Normal aortic distensibility/ pulse wave velocity in children

In the only publication of aortic distensibility and pulse wave velocity in children, distensibility was measured on gradient echo cine CMR images and pulse wave velocity was measured on phase-contrast cine CMR [53]. Distensibility was calculated as (Amax – Amin)/Amin x (Pmax – Pmin), where Amax and Amin represent the maximal and minimal cross-sectional areal of the aorta, and Pmax and Pmin represent the systolic and diastolic blood pressure measured with a sphygmomanometer cuff around the right arm. Pulse wave velocity was calculated as Δx/Δt, where Δx is defined as the length of the centerline between the sites of flow measurement in the ascending and descending aorta and Δt represents the time delay between the flow curve obtained in the descending aorta relative to the flow curve obtained in the ascending aorta (Figure 17). Aortic distensibility and pulse wave velocity did not vary by gender. Aortic distensibility decreases with age and correlates with height, body weight and BSA [53]. There is a single publication only of a systematic evaluation of normal aortic distensibility and pulse wave velocity in children (Table 42). Reference percentiles by age according to reference [53] are presented in Figures 18 and 19.
Table 42

References, normal aortic distensibility and pulse wave velocity in children

First author, year CMR technique N, male: female Age range (yrs)
Voges, 2012 [53]Cine GRE; phase-contrast cine CMR30:412.3-28.3

GRE = gradient echo; yrs = years.

Figure 18

Reference percentiles for aortic distensibility measured at four different sites (ascending aorta [a], aortic arch [b], aortic isthmus [c] and descending aorta above the diaphragm [d]) on cine GRE images at maximal aortic distension according to reference [ 53 ].

Figure 19

Reference percentiles for aortic pulse wave velocity according to reference [ 53 ].

References, normal aortic distensibility and pulse wave velocity in children GRE = gradient echo; yrs = years. Reference percentiles for aortic distensibility measured at four different sites (ascending aorta [a], aortic arch [b], aortic isthmus [c] and descending aorta above the diaphragm [d]) on cine GRE images at maximal aortic distension according to reference [ 53 ]. Reference percentiles for aortic pulse wave velocity according to reference [ 53 ].

Normal values of myocardial T1 relaxation time and the extracellular volume (ECV)

Most of the published myocardial T1 values have been acquired using a Modified Look-Locker Inversion Recovery (MOLLI) [59] or shortened-MOLLI (ShMOLLI) [60] method, combined with a balanced SSFP read out [59]. The MOLLI method acquires data over 17 heartbeats with a 3(3bt)3(3bt)5 sampling pattern, while ShMOLLI has been described with a 9 heart beat breath-hold and a 5(1bt)1(1bt)1 sampling pattern, although variations of these acquisition schemes have been proposed [60]. An alternative sampling method is saturation recovery single-shot acquisition (SASHA) in which a first single-shot bSSFP image is acquired without magnetization preparation followed by nine images prepared with variable saturation recovery times [61]. All methods usually acquire images at end diastole to limit cardiac motion artifacts [59] but acquisition of T1 maps at systole has been shown to be feasible [62]. Post contrast T1 values have been performed following a bolus or primed infusion (Equilibrium-EQCMR) with good agreement of ECV values up to 40% [63].

Factors affecting T1 and ECV

Field strength has a significant effect on T1 values; with 3T scans producing 28% higher native T1 and 14% higher post contrast T1 values when compared with 1.5T [62]. Post contrast T1 is also affected by the dose and relaxivity of the contrast agent used, contrast clearance, and the time between injection and measurement [62,64,65]. There is also greater heterogeneity for a T1 native normal range at 3 Tesla [62,66,67]. Further, it has been shown that T1 varies by cardiac phase (diastole versus systole) and region of measurement (septal versus non-septal) [62]. ECV values are relatively unaffected by field strength (3T versus 1.5T). Both native T1 and ECV values have been shown to be less reliable in the infero-lateral wall [62,68]. Flip-angle and pre-pulse can also affect normal values, with the adiabatic pre-pulse increasing native T1 values by approximately 25 ms compared with non-adiabatic pre-pulses. FLASH mapping sequences produce significantly lower native T1 values than bSSFP methods [69,70]. T1 maps are based on pixel-wise quantification of longitudinal relaxation of the acquired images. Native T1 measures a composite signal from myocytes and interstitium and is expressed in ms [71]. Measurements that correlate pre and post contrast T1 myocardial values and blood T1 have been proposed, such as the partition coefficient or the extracellular volume fraction (ECV), expressed as a percantage [72]. Offline post-processing involves manually tracing endocardial and epicardial contours [65,73] (Figure 20) or placing a region of interest within the septal myocardium using a prototype tool [67]. Inclusion of blood pool or adjacent tissue should be carefully avoided. Motion correction is generally used to counter undesired breathing motion. However, motion correction can only correct for in-plane motion and not through-plane motion. All methods, therefore, are vulnerable to partial volume effects. Some investigators also corrected for this with smaller regions of interest and co-registration of images [74].
Figure 20

T1 maps pre- and post-contrast with left ventricular endocardial and epicardial contours.

T1 maps pre- and post-contrast with left ventricular endocardial and epicardial contours. Increasing age has been shown to increase ECV in healthy volunteers in one publication [68] and females less than 45 years have been shown to have a higher precontrast T1 [74]. Several studies have shown a strong correlation between T1 values by CMR and diffuse myocardial fibrosis on myocardial biopsy [71,75,76], but the rapid evolution of acquisition methods over the past years has led to inconsistent T1 values reported in the literature. In order to reflect the current literature, the normal values presented here are classified by field strength and acquisition pulse sequence and list pre contrast, post contrast, and ECV values where available. It should be noted that a universal normal range for T1 cannot be determined given the heterogeneity of acquisition pulse sequences used in the existing literature and because no true reference value for in vivo T1 exists. Table 43 is a summary of publications over the last years presenting normal values based on ≥ 20 healthy subjects as available in December 2013.
Table 43

Normal native and post contrast T1 time and ECV (mean ± SD)

Author n Age (yrs) Male (%) Sequence Gd type & dose (mmol/kg) Time p.c. (min) T1 native (ms) T1 p.c. (ms) ECV Slice(s), % thickness
1.5 Tesla
Iles (2008) [77]2038 ± 350GE, VAST 3–4 BH0.2 Magnevist15975 ± 62564 ± 23n/a3x SAX & 4Ch full thickness
Ugander (2012) [68]6049 ± 1752MOLLI0.15-0.2 Magnevist15-20Not reportedNot reported27 ± 31x SAX & 4Ch full thickness
Kellman (2012) [78]6244 ± 1748MOLLI0.15 Magnevist15-20965 ± 35Not reported25 ± 3**1x SAX & 4Ch midwall
Flett (2012) [69]3064 ± 1367FLASH, multi-BH0.1 Dotarem45-80 EQCMR698 ± 86408 ± 33n/a2x SAX septum
Fontana (2012) [76]5047 ± 753ShMOLLI*0.1 Dotarem45-80 EQCMRNot reportedNot reported26 ± 32x SAX septum
Sado (2012) [70]8144 ± 1752FLASH, multi-BH0.1 Dotarem45-80 EQCMRNot reportedNot reported25 ± 42x SAX septum
Kawel (2012) [62]2328 ± 636MOLLI0.15 Magnevist121003 ± 46522 ± 3428 ± 31x SAX full thickness
Piechnik (2013) [74]34238 ± 1549ShMOLLI*No contrast givenn/a962 ± 25n/an/a3x SAX full thickness
Bull (2013) [75]3362 ± 764ShMOLLINo contrast givenn/a944 ± 16n/an/a1x SAX septal midwall
3 Tesla
Kawel (2012) [65]2328 ± 631MOLLI0.15 Magnevist121286 ± 59538 ± 3428 ± 31x SAX full thickness
Kawel (2012) [65]2328 ± 633MOLLI0.1 Multihance12As above555 ± 3327 ± 31x SAX full thickness
Puntmann (2013) [67]2138 ± 623MOLLI*0.2 Gadobutrol151056 ± 27454 ± 5326 ± 51x SAX septal midwall
Puntmann (2013) [79]3043 ± 963MOLLI*0.2 Gadobutrol101070 ± 55402 ± 5827 ± 51x SA septal midwall
Liu (2012) [80]2429 ± 633MOLLI0.15 Magnevist121159 ± 39Not reported27 ± 31x SAX full thickness
Liu (2012) [80]2429 ± 633MOLLI0.1 Multihance121159 ± 39Not reported26 ± 31x SAX full thickness

Age: mean ± standard deviation; yrs = years; n = number of subjects; Gd = Gadolinium; p.c. = post contrast; ECV = extracellular volume fraction; MOLLI = modified look-locker inversion recovery; ShMOLLI = shortened MOLLI; GE = gradient echo; VAST = variable sampling of k-space; BH = breath hold; LL = Look-locker; FLASH = fast low angle single shot recovery; SAX = short axis; 4Ch = 4 chamber; Hb = heart beat; EQCMR = equilibrium contrast cardiovascular magnetic resonance; * = adiabatic pre pulse; ** = automated motion correction and co-registration.

Normal native and post contrast T1 time and ECV (mean ± SD) Age: mean ± standard deviation; yrs = years; n = number of subjects; Gd = Gadolinium; p.c. = post contrast; ECV = extracellular volume fraction; MOLLI = modified look-locker inversion recovery; ShMOLLI = shortened MOLLI; GE = gradient echo; VAST = variable sampling of k-space; BH = breath hold; LL = Look-locker; FLASH = fast low angle single shot recovery; SAX = short axis; 4Ch = 4 chamber; Hb = heart beat; EQCMR = equilibrium contrast cardiovascular magnetic resonance; * = adiabatic pre pulse; ** = automated motion correction and co-registration. For SASHA, only limited normal values are available. T1 estimates based on SASHA are higher than with MOLLI methods. One study reported SASHA derived T1 values in 39 normal subjects of 1170 ± 9 ms at 1.5T [61]. We conclude that at present, normal native T1 values are specific to pulse sequences and scanner manufacturer. For diagnostic purposes it is most important to use a method with a tight normal range, good reproducibility and sensitivity to disease.

Normal values of myocardial T2* relaxation time

Quantification of the T2* relaxation time plays an important role for estimation of myocardial iron overload [81]. For quantification of the myocardial T2* time, the gradient-echo T2* technique with multiple increasing TEs is preferred over the spin-echo T2 technique due to a greater sensitivity to iron deposition [82-84]. Usually a single-breath hold technique is used. Normal values and a grading system for myocardial iron overload are available for 1.5T [84]. Since the gradient-echo T2* technique is vulnerable to distortions of the local magnetic field e.g. by air-tissue interfaces, measurements are obtained by placing a region of interest on the interventricular septum of a midventricular short axis slice, since the septum is surrounded by blood on both sides [83] (Figure 21).
Figure 21

Measurements for myocardial T2* are obtained in the septum.

Measurements for myocardial T2* are obtained in the septum. T2* times are frequently reported as relaxation rate, representing the reciprocal of the time constant and calculated as R2* = 1000/T2*. The unit of R2* is Hertz or s−1 [83]. It has been shown that T2* does not correlate with age [85]. To our knowledge the relationship between other demographic parameters and T2* has not been assessed yet. Generally a T2* value - measured at the interventricular septum using a multiecho GRE sequence at 1.5T - of >20 ms is considered normal while the mean myocardial T2* is around 40 ms [81]. Examples of studies that used the current multiecho GRE technique with a sample size of >10 healthy subjects are presented in Table 44.
Table 44

References (examples), normal myocardial T2* values

First author, year CMR technique N, male: female Age range (yrs) Mean ± SD (ms)
Kirk, 2010 [85]GRE, 8 echo times (2.6-16.74 ms)38:2518-7736.3*
Pepe 2006 [86]GRE, 9 echo times (2.2-20.3)14:6(33 ± 9**)36.4 ± 6.7
Anderson, 2001 [82]GRE, 8 echo times (2.2-20.1 ms)9:626-3952 ± 16

GRE = gradient-echo; yrs = years; * = SD not indicated in original publication; ** = mean ± SD, range not mentioned in original publication.

References (examples), normal myocardial T2* values GRE = gradient-echo; yrs = years; * = SD not indicated in original publication; ** = mean ± SD, range not mentioned in original publication. Depending on the risk to develop heart failure as a consequence of myocardial iron overload, a grading system for disease severity has been published (Table 45) [87].
Table 45

Grading of iron overload based on T2* measurements according to [81,87]

Iron overload T2* (ms)
normal>20
iron overload<20
severe iron overload<10
Grading of iron overload based on T2* measurements according to [81,87]

Regional Measurements and Cardiac Strain

A number of imaging methods have been developed to acquire cardiac strain information from CMR including cine CMR, tagged MR, phase-contrast CMR (PC-CMR), velocity encoded CMR, displacement encoding with stimulated echoes (DENSE), and strain-encoding (SENC) [88,89]. However, tagged CMR remains a widely validated reproducible tool for strain estimation. The method is used in clinical studies and is considered the reference standard for assessing regional function [90,91]. Cardiac strain is a dimensionless measurement of the deformation that occurs in the myocardium. Cardiac strain can be reported as three normal strains (circumferential, radial, and longitudinal) and six shear strains—the angular change between two originally mutually orthogonal line elements, with the more clinically investigated shear strain in the circumferential-longitudinal shear strain (also known as torsion). There are a number of different methods to quantify strain: registration methods, feature-based tracking methods, deformable models, Gabor Filter Banks, optic flow methods, harmonic phase analysis (HARP) [92], and local sine wave modeling (SinMod) [88]. Technical review papers for these methods can be found in the following literature [93-96]. HARP has become one of the most widely used methods for analyzing tagged MR images for cardiac strain, in part due to its large scale use in the Multi-Ethnic Study of Atherosclerosis (MESA) trial [92,97]. Strain patterns are reported according to the 16 and 17 segment model of the American College of Echocardiology. Consistent manual tracing of the endocardial and epicardial contours is necessary to reproducible strain results. With tagged CMR, midwall strain is preferred to epicardial and endocardial strain to maximize the amount of tagging data available for strain calculations [95,98]. With HARP analysis such as that used in the MESA trial [92], careful selection of the first harmonic is necessary. With tagged CMR, it has been noted that age is associated with decrease in peak circumferential or longitudinal shortening [99,100]. In tagged CMR studies, gender also affects normal values. Cardiac strain values for women are higher than those of men [101,102]. Several studies have presented cohorts of normal individuals for determining normal strain of the left ventricle. For the purpose of this review, only cohorts of 30 or more normal subjects using SPAMM tagging have been included. (Feature tracking methods are being developed for strain, but are being validation in comparison to SPAMM tagging.) Inclusion criteria include a full description of the subject cohort (including the analysis methods used), age and gender of subjects. Table 46 represents a summary of publications reporting normal values for midwall strain that fit the criteria [89,90,98].
Table 46

Normal values for circumferential, longitudinal und radial strain (maximal strain in %; mean±SD) according to previous publications

Author n Age (yrs) Acquis. method Estimation method Tagged resol. FS (T) base mid ap sept ant lat inf
Circumferential Strain
Moore (2000) [98]3137 ± 11SPAMMFindTags6 mm1.5−0.19±0.04−0.19±0.05−0.22±0.05−0.17±0.03−0.22±0.05−0.22±0.04−0.18±0.05
Cupps (2010) [89]5032.8±10.6SPAMMfinite element model7 mm1.5−0.19±0.04−0.21±0.04−0.20±0.04−0.18±0.03−0.20±0.04−0.23±0.04−0.19±0.04
Del-Canto (2013) [90]3658.8 ± 11.6SPAMMSinMod7 mm1.5−0.17 ± 0.03−0.20 ± 0.03−0.20 ± 0.03−0.16 ± 0.04−0.20 ± 0.04−0.22 ±0.04−0.18 ± 0.04
Venkatesh (2014) [103]12958.8 ± 9.3SPAMMHARP7 mm1.5−15.1 ± 3.2−18.0 ± 2.2−17.9 ± 2.5
Longitudinal Strain
Moore (2000) [98]3137 ± 11SPAMMFindTags6 mm1.5−0.15±0.03−0.15±0.03−0.19±0.04−0.16±0.04−0.16±0.04−0.16±0.04−0.16±0.04
Cupps (2010) [89]5032.8±10.6SPAMMfinite element model7 mm1.5−0.13±0.04−0.15±0.03−0.18±0.05−0.16±0.040.15±0.04−0.15±0.04−0.15±0.05
Radial Strain
Moore (2000) [98]3137 ± 11SPAMMFindTags6 mm1.50.45±0.260.42±0.260.48±0.330.41±0.190.54±0.280.46±0.230.38±0.38
Del-Canto (2013) [90]3658.8 ± 11.6SPAMMSinMod7 mm1.50.13 ± 0.040.09 ± 0.040.12 ± 0.040.09 ±0.050.10 ±0.050.12 ±0.070.14±0.07
Venkatesh (2014) [103]12958.8 ± 9.3SPAMMHARP7 mm1.527.4 ± 5.624.8 ± 5.323.4 ± 6.7

yrs = years; Acquis. = Acquisition; resol. = resolution; FS = field strength; T = Tesla; SPAMM = spatial modulation of the magnetization; mid = mid cavity; ap = apical level; sept = septal; ant = anterior; lat = lateral; inf = inferior.

Normal values for circumferential, longitudinal und radial strain (maximal strain in %; mean±SD) according to previous publications yrs = years; Acquis. = Acquisition; resol. = resolution; FS = field strength; T = Tesla; SPAMM = spatial modulation of the magnetization; mid = mid cavity; ap = apical level; sept = septal; ant = anterior; lat = lateral; inf = inferior. With tagged CMR, normal midwall circumferential [89,92,93,98,101,104] and longitudinal [89,96,98,104] strain values are relatively comparable between studies. For radiation strain, moderate differences between published results exist for reference values, probably due to low tag density by most methods in the radial direction [90,96-98,101,104].

Conclusions

Cardiovascular magnetic resonance enables quantification of various functional and morphological parameters of the cardiovascular system. This review lists reference values and their influencing factors of these parameters based on current CMR techniques and sequences. Advantages of a quantitative evaluation are a better differentiation between pathology and normal conditions, grading of pathologies, monitoring changes under therapy, and evaluating prognosis and the possibility of comparing different groups of patients and normal subjects.
  101 in total

Review 1.  Cardiovascular applications of phase-contrast MRI.

Authors:  Monvadi B Srichai; Ruth P Lim; Samson Wong; Vivian S Lee
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

2.  T2* magnetic resonance: iron and gold.

Authors:  Dudley J Pennell
Journal:  JACC Cardiovasc Imaging       Date:  2008-09

3.  Measuring aortic diameter with different MR techniques: comparison of three-dimensional (3D) navigated steady-state free-precession (SSFP), 3D contrast-enhanced magnetic resonance angiography (CE-MRA), 2D T2 black blood, and 2D cine SSFP.

Authors:  Silke Potthast; Lee Mitsumori; Luana A Stanescu; Michael L Richardson; Kelley Branch; Theodore J Dubinsky; Jeffrey H Maki
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

4.  Age-associated elongation of the ascending aorta in adults.

Authors:  Jun Sugawara; Koichiro Hayashi; Takashi Yokoi; Hirofumi Tanaka
Journal:  JACC Cardiovasc Imaging       Date:  2008-11

5.  Sex-specific pediatric percentiles for ventricular size and mass as reference values for cardiac MRI: assessment by steady-state free-precession and phase-contrast MRI flow.

Authors:  Samir Sarikouch; Brigitte Peters; Matthias Gutberlet; Birte Leismann; Andrea Kelter-Kloepping; Hermann Koerperich; Titus Kuehne; Philipp Beerbaum
Journal:  Circ Cardiovasc Imaging       Date:  2009-10-09       Impact factor: 7.792

6.  Cardiac T2* magnetic resonance for prediction of cardiac complications in thalassemia major.

Authors:  P Kirk; M Roughton; J B Porter; J M Walker; M A Tanner; J Patel; D Wu; J Taylor; M A Westwood; L J Anderson; D J Pennell
Journal:  Circulation       Date:  2009-10-02       Impact factor: 29.690

7.  Aortic root measurement by cardiovascular magnetic resonance: specification of planes and lines of measurement and corresponding normal values.

Authors:  Elisabeth D Burman; Jennifer Keegan; Philip J Kilner
Journal:  Circ Cardiovasc Imaging       Date:  2008-07-30       Impact factor: 7.792

8.  Normal biventricular function, volumes, and mass in children aged 8 to 17 years.

Authors:  Daniëlle Robbers-Visser; Eric Boersma; Willem A Helbing
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

9.  Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance.

Authors:  Emanuela Valsangiacomo Buechel; Thomas Kaiser; Clare Jackson; Achim Schmitz; Christian J Kellenberger
Journal:  J Cardiovasc Magn Reson       Date:  2009-06-21       Impact factor: 5.364

10.  Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study.

Authors:  Peter A Cain; Ragnhild Ahl; Erik Hedstrom; Martin Ugander; Ase Allansdotter-Johnsson; Peter Friberg; Hakan Arheden
Journal:  BMC Med Imaging       Date:  2009-01-21       Impact factor: 1.930

View more
  221 in total

1.  Left ventricular mass and systolic function in children with chronic kidney disease-comparing echocardiography with cardiac magnetic resonance imaging.

Authors:  Raoul Arnold; Daniel Schwendinger; Sabine Jung; Martin Pohl; Bernd Jung; Julia Geiger; Charlotte Gimpel
Journal:  Pediatr Nephrol       Date:  2015-09-05       Impact factor: 3.714

Review 2.  Sudden Cardiac Death Substrate Imaged by Magnetic Resonance Imaging: From Investigational Tool to Clinical Applications.

Authors:  Katherine C Wu
Journal:  Circ Cardiovasc Imaging       Date:  2017-07       Impact factor: 7.792

Review 3.  Novel Insights and Treatment Strategies for Right Heart Failure.

Authors:  Weiqin Lin; Ai-Ling Poh; W H Wilson Tang
Journal:  Curr Heart Fail Rep       Date:  2018-06

4.  BP in Dialysis: Results of a Pilot Study.

Authors:  Dana C Miskulin; Jennifer Gassman; Ronald Schrader; Ambreen Gul; Manisha Jhamb; David W Ploth; Lavinia Negrea; Raymond Y Kwong; Andrew S Levey; Ajay K Singh; Antonia Harford; Susan Paine; Cynthia Kendrick; Mahboob Rahman; Philip Zager
Journal:  J Am Soc Nephrol       Date:  2017-12-06       Impact factor: 10.121

5.  Left atrium passive ejection fraction is the most sensitive index of type 2 diabetes mellitus-related cardiac changes.

Authors:  Yongning Shang; Xiaochun Zhang; Weiling Leng; Xiaotian Lei; Liu Chen; Ziwen Liang; Jian Wang
Journal:  Int J Cardiovasc Imaging       Date:  2017-07-18       Impact factor: 2.357

6.  Reference ranges of left ventricular structure and function assessed by contrast-enhanced cardiac MR and changes related to ageing and hypertension in a population-based study.

Authors:  Robin Bülow; Till Ittermann; Marcus Dörr; Axel Poesch; Sönke Langner; Henry Völzke; Norbert Hosten; Marc Dewey
Journal:  Eur Radiol       Date:  2018-03-14       Impact factor: 5.315

7.  Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease.

Authors:  Charlotte Gimpel; Bernd A Jung; Sabine Jung; Johannes Brado; Daniel Schwendinger; Barbara Burkhardt; Martin Pohl; Katja E Odening; Julia Geiger; Raoul Arnold
Journal:  Pediatr Radiol       Date:  2016-12-13

8.  Left atrial size and function in a South Asian population and their potential influence on the risk of atrial fibrillation.

Authors:  James O'Neill; Peter P Swoboda; Sven Plein; Muzahir H Tayebjee
Journal:  Clin Cardiol       Date:  2018-10-21       Impact factor: 2.882

9.  Free-breathing, non-ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking.

Authors:  Jaime L Shaw; Qi Yang; Zhengwei Zhou; Zixin Deng; Christopher Nguyen; Debiao Li; Anthony G Christodoulou
Journal:  Magn Reson Med       Date:  2018-11-19       Impact factor: 4.668

Review 10.  Myocardial T1 and ECV Measurement: Underlying Concepts and Technical Considerations.

Authors:  Austin A Robinson; Kelvin Chow; Michael Salerno
Journal:  JACC Cardiovasc Imaging       Date:  2019-09-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.