Literature DB >> 12006694

Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation.

Joachim Lotz1, Christian Meier, Andreas Leppert, Michael Galanski.   

Abstract

Phase-contrast magnetic resonance (MR) imaging is a well-known but undervalued method of obtaining quantitative information on blood flow. Applications of this technique in cardiovascular MR imaging are expanding. According to the sequences available, phase-contrast measurement can be performed in a breath hold or during normal respiration. Prospective as well as retrospective gating techniques can be used. Common errors in phase-contrast imaging include mismatched encoding velocity, deviation of the imaging plane, inadequate temporal resolution, inadequate spatial resolution, accelerated flow and spatial misregistration, and phase offset errors. Flow measurements are most precise if the imaging plane is perpendicular to the vessel of interest and flow encoding is set to through-plane flow. The sequence should be repeated at least once, with a high encoding velocity used initially. If peak velocity has to be estimated, flow measurement is repeated with an adapted encoding velocity. The overall error of a phase-contrast flow measurement comprises errors during prescription as well as errors that occur during image analysis of the flow data. With phase-contrast imaging, the overall error in flow measurement can be reduced to less than 10%, an acceptable level of error for routine clinical use. Copyright RSNA, 2002

Mesh:

Year:  2002        PMID: 12006694     DOI: 10.1148/radiographics.22.3.g02ma11651

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  171 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 2.  Assessment of pulmonary hypertension by CT and MR imaging.

Authors:  Sebastian Ley; Karl-Friedrich Kreitner; Christian Fink; Claus P Heussel; Mathias M Borst; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-01-23       Impact factor: 5.315

Review 3.  When to order cardiovascular magnetic resonance in adults with congenital heart disease.

Authors:  Sonya V Babu-Narayan; Philip J Kilner; Michael A Gatzoulis
Journal:  Curr Cardiol Rep       Date:  2003-07       Impact factor: 2.931

4.  Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta.

Authors:  Umberto Morbiducci; Raffaele Ponzini; Giovanna Rizzo; Marco Evanghelos Biancolini; Francesco Iannaccone; Diego Gallo; Alberto Redaelli
Journal:  Med Biol Eng Comput       Date:  2011-12-23       Impact factor: 2.602

5.  Magnetic resonance imaging flow quantification of non-occlusive excimer laser-assisted EC-IC high-flow bypass in the treatment of complex intracranial aneurysms.

Authors:  C Brockmann; L Gerigk; P Vajkoczy; C Groden; E Neumaier-Probst
Journal:  Clin Neuroradiol       Date:  2011-12-03       Impact factor: 3.649

6.  Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold.

Authors:  Michael A Bolen; Randolph M Setser; Ruvin S Gabriel; Rahul D Renapurkar; Yasmeen Tandon; Michael L Lieber; Milind Y Desai; Scott D Flamm
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

7.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

8.  Changes in AVM angio-architecture and hemodynamics after stereotactic radiosurgery assessed by dynamic MRA and phase contrast flow assessments: a prospective follow-up study.

Authors:  Lydia Schuster; E Schenk; F Giesel; T Hauser; L Gerigk; A Zabel-Du-Bois; Marco Essig
Journal:  Eur Radiol       Date:  2010-12-22       Impact factor: 5.315

Review 9.  Valvular heart disease: what does cardiovascular MRI add?

Authors:  Pier Giorgio Masci; Steven Dymarkowski; Jan Bogaert
Journal:  Eur Radiol       Date:  2007-08-29       Impact factor: 5.315

10.  Reduced fetal cerebral oxygen consumption is associated with smaller brain size in fetuses with congenital heart disease.

Authors:  Liqun Sun; Christopher K Macgowan; John G Sled; Shi-Joon Yoo; Cedric Manlhiot; Prashob Porayette; Lars Grosse-Wortmann; Edgar Jaeggi; Brian W McCrindle; John Kingdom; Edward Hickey; Steven Miller; Mike Seed
Journal:  Circulation       Date:  2015-03-11       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.