F Baan1,2, R Bruggink3,4, J Nijsink3, T J J Maal3,5, E M Ongkosuwito4,6. 1. Radboudumc 3DLab The Netherlands, Radboud university medical center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands. frank.baan@radboudumc.nl. 2. Department of Dentistry, section of Orthodontics and Craniofacial Biology, Radboud university medical center, Philips van Leydenlaan 25, 6525, EX, Nijmegen, The Netherlands. frank.baan@radboudumc.nl. 3. Radboudumc 3DLab The Netherlands, Radboud university medical center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands. 4. Department of Dentistry, section of Orthodontics and Craniofacial Biology, Radboud university medical center, Philips van Leydenlaan 25, 6525, EX, Nijmegen, The Netherlands. 5. Department of Oral and Maxillofacial Surgery, Radboud university medical center, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands. 6. Amalia Cleft and Craniofacial Centre, Radboud university medical centre, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands.
Abstract
PURPOSE: The purpose of this study was to evaluate the clinical accuracy of the fusion of intra-oral scans in cone-beam computed tomography (CBCT) scans using two commercially available software packages. MATERIALS AND METHODS: Ten dry human skulls were subjected to structured light scanning, CBCT scanning, and intra-oral scanning. Two commercially available software packages were used to perform fusion of the intra-oral scans in the CBCT scan to create an accurate virtual head model: IPS CaseDesigner® and OrthoAnalyzer™. The structured light scanner was used as a gold standard and was superimposed on the virtual head models, created by IPS CaseDesigner® and OrthoAnalyzer™, using an Iterative Closest Point algorithm. Differences between the positions of the intra-oral scans obtained with the software packages were recorded and expressed in six degrees of freedom as well as the inter- and intra-observer intra-class correlation coefficient. RESULTS: The tested software packages, IPS CaseDesigner® and OrthoAnalyzer™, showed a high level of accuracy compared to the gold standard. The accuracy was calculated for all six degrees of freedom. It was noticeable that the accuracy in the cranial/caudal direction was the lowest for IPS CaseDesigner® and OrthoAnalyzer™ in both the maxilla and mandible. The inter- and intra-observer intra-class correlation coefficient showed a high level of agreement between the observers. CLINICAL RELEVANCE: IPS CaseDesigner® and OrthoAnalyzer™ are reliable software packages providing an accurate fusion of the intra-oral scan in the CBCT. Both software packages can be used as an accurate fusion tool of the intra-oral scan in the CBCT which provides an accurate basis for 3D virtual planning.
PURPOSE: The purpose of this study was to evaluate the clinical accuracy of the fusion of intra-oral scans in cone-beam computed tomography (CBCT) scans using two commercially available software packages. MATERIALS AND METHODS: Ten dry human skulls were subjected to structured light scanning, CBCT scanning, and intra-oral scanning. Two commercially available software packages were used to perform fusion of the intra-oral scans in the CBCT scan to create an accurate virtual head model: IPS CaseDesigner® and OrthoAnalyzer™. The structured light scanner was used as a gold standard and was superimposed on the virtual head models, created by IPS CaseDesigner® and OrthoAnalyzer™, using an Iterative Closest Point algorithm. Differences between the positions of the intra-oral scans obtained with the software packages were recorded and expressed in six degrees of freedom as well as the inter- and intra-observer intra-class correlation coefficient. RESULTS: The tested software packages, IPS CaseDesigner® and OrthoAnalyzer™, showed a high level of accuracy compared to the gold standard. The accuracy was calculated for all six degrees of freedom. It was noticeable that the accuracy in the cranial/caudal direction was the lowest for IPS CaseDesigner® and OrthoAnalyzer™ in both the maxilla and mandible. The inter- and intra-observer intra-class correlation coefficient showed a high level of agreement between the observers. CLINICAL RELEVANCE: IPS CaseDesigner® and OrthoAnalyzer™ are reliable software packages providing an accurate fusion of the intra-oral scan in the CBCT. Both software packages can be used as an accurate fusion tool of the intra-oral scan in the CBCT which provides an accurate basis for 3D virtual planning.
Authors: Luc M Verhamme; Gert J Meijer; Stefaan J Bergé; Rik A Soehardi; Tong Xi; Anton F J de Haan; Filip Schutyser; Thomas J J Maal Journal: Clin Implant Dent Relat Res Date: 2014-09-02 Impact factor: 3.932
Authors: Gwen R J Swennen; Wouter Mollemans; Calix De Clercq; Johan Abeloos; Philippe Lamoral; Frank Lippens; Nathalie Neyt; Jan Casselman; Filip Schutyser Journal: J Craniofac Surg Date: 2009-03 Impact factor: 1.046
Authors: R Schreurs; F Baan; C Klop; L Dubois; L F M Beenen; P E M H Habets; A G Becking; T J J Maal Journal: Sci Rep Date: 2021-09-10 Impact factor: 4.379