Literature DB >> 12408315

Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

Jeffrey F Williamson1, Bruce R Whiting, Jasenka Benac, Ryan J Murphy, G James Blaine, Joseph A O'Sullivan, David G Politte, Donald L Snyder.   

Abstract

X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12408315     DOI: 10.1118/1.1509443

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  Sequentially reweighted TV minimization for CT metal artifact reduction.

Authors:  Xiaomeng Zhang; Lei Xing
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  Technical Note: Measurement of bow tie profiles in CT scanners using radiochromic film.

Authors:  Bruce R Whiting; Andreea C Dohatcu; Joshua D Evans; David G Politte; Jeffrey F Williamson
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

5.  Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography.

Authors:  V Hirschinger; S Hanke; U Hirschfelder; E Hofmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

6.  U-net based metal segmentation on projection domain for metal artifact reduction in dental CT.

Authors:  Mohamed A A Hegazy; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Biomed Eng Lett       Date:  2019-04-29

7.  A comparison of linear interpolation models for iterative CT reconstruction.

Authors:  Katharina Hahn; Harald Schöndube; Karl Stierstorfer; Joachim Hornegger; Frédéric Noo
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

8.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

9.  Photon starvation artifacts of X-ray CT: their true cause and a solution.

Authors:  Issei Mori; Yoshio Machida; Makoto Osanai; Kazuhiro Iinuma
Journal:  Radiol Phys Technol       Date:  2012-10-10

10.  Measurement of bow tie profiles in CT scanners using a real-time dosimeter.

Authors:  Bruce R Whiting; Joshua D Evans; Andreea C Dohatcu; Jeffrey F Williamson; David G Politte
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.