Literature DB >> 19826202

A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Daniel Prell1, Yiannis Kyriakou, Marcel Beister, Willi A Kalender.   

Abstract

Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs)).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19826202     DOI: 10.1088/0031-9155/54/21/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

1.  Successive iterative restoration applied to streak artifact reduction in X-ray CT image of dento-alveolar region.

Authors:  Jian Dong; Atsushi Kondo; Kosuke Abe; Yoshihiko Hayakawa
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-01-05       Impact factor: 2.924

2.  Artifact reduction of different metallic implants in flat detector C-arm CT.

Authors:  S-C Hung; C-C Wu; C-J Lin; W-Y Guo; C-B Luo; F-C Chang; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-23       Impact factor: 3.825

Review 3.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

5.  Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography.

Authors:  V Hirschinger; S Hanke; U Hirschfelder; E Hofmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

6.  U-net based metal segmentation on projection domain for metal artifact reduction in dental CT.

Authors:  Mohamed A A Hegazy; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Biomed Eng Lett       Date:  2019-04-29

7.  Model Image-Based Metal Artifact Reduction for Computed Tomography.

Authors:  Dmytro Luzhbin; Jay Wu
Journal:  J Digit Imaging       Date:  2020-02       Impact factor: 4.056

Review 8.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

9.  Statistical iterative reconstruction for streak artefact reduction when using multidetector CT to image the dento-alveolar structures.

Authors:  J Dong; Y Hayakawa; C Kober
Journal:  Dentomaxillofac Radiol       Date:  2014-04-22       Impact factor: 2.419

10.  Prelimbic Cortical Injections of a GABA Agonist and Antagonist: In Vivo Quantification of the Effect in the Rat Brain Using [(18)F] FDG MicroPET.

Authors:  Joke Parthoens; Stijn Servaes; Jeroen Verhaeghe; Sigrid Stroobants; Steven Staelens
Journal:  Mol Imaging Biol       Date:  2015-12       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.