Literature DB >> 19163157

A high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability.

Xiaoli Li1, Cate Lockhart, Tom K Lewellen, Robert S Miyaoka.   

Abstract

We report on a high resolution, monolithic crystal PET detector design that provides depth of interaction (DOI) positioning within the crystal and is compatible for operation in a MRI scanner to support multimodal anatomic and functional imaging. Our design utilizes a novel sensor on the entrance surface (SES) design combined with a maximum likelihood positioning algorithm. The sensor will be a two-dimensional array of micro-pixel avalanche photodiodes (MAPD). MAPDs are a new type of solid-state photodetector with Geiger mode operation that can provide signal gain similar to a photomltipiler tube (PMT). In addition, they can be operated in high magnetic fields to support PET/MR imaging. Utilizing a multi-step simulation process, we determined the intrinsic spatial resolution characteristics of a detector using the proposed design. For a 48.8 mm by 48.8 mm by 15 mm LSO crystal detector readout by an 8 by 8 array of 5.8 mm by 5.8 mm MAPD elements the intrinsic spatial resolution is 0.83 mm FWHM in X, 0.92 mm FWHM in Y and 1.83 mm FWHM in Z (i.e., DOI) for normally incident photons. Comparing the results versus using a conventional design with the photosensors on the backside of the crystal, an average improvement of 25% in X, 23% in Y, and 20% in Z is achieved.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19163157      PMCID: PMC2729160          DOI: 10.1109/IEMBS.2008.4649654

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  3 in total
  11 in total

1.  SCOUT: A Fast Monte-Carlo Modeling Tool of Scintillation Camera Output.

Authors:  William C J Hunter; Harrison H Barrett; Thomas K Lewellen; Robert S Miyaoka; John P Muzi; Xiaoli Li; Wendy McDougald; Lawrence R Macdonald
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010

2.  Performance Evaluation of Small Animal PET Scanners With Different System Designs.

Authors:  Xiaoli Li; Adam M Alessio; Thompson H Burnett; Thomas K Lewellen; Roberts Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

3.  New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

4.  Design of a Real Time FPGA-based Three Dimensional Positioning Algorithm.

Authors:  Nathan G Johnson-Williams; Robert S Miyaoka; Xiaoli Li; Tom K Lewellen; Scott Hauck
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-11-01

5.  Measurements of entrance-surface vs. conventional single-ended readout of a monolithic scintillator.

Authors:  William C J Hunter; Wendy McDougald; Jerome J Griesmer; Lingxiong Shao; Robert Zahn; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

6.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

7.  Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

8.  Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs.

Authors:  Xiaoli Li; William C J Hunter; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2012       Impact factor: 1.679

9.  Resolution Properties of a Prototype Continuous Miniature Crystal Element (cMiCE) Scanner.

Authors:  Robert S Miyaoka; Xiaoli Li; William Hunter; Larry A Pierce; Wendy McDougald; Paul E Kinahan; Thomas K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2011-10       Impact factor: 1.679

10.  SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output.

Authors:  William C J Hunter; Harrison H Barrett; John P Muzi; Wendy McDougald; Lawrence R MacDonald; Robert S Miyaoka; Thomas K Lewellen
Journal:  Phys Med Biol       Date:  2013-05-02       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.