Literature DB >> 18364542

Parametric positioning of a continuous crystal PET detector with depth of interaction decoding.

T Ling1, T H Burnett, T K Lewellen, R S Miyaoka.   

Abstract

Here we demonstrate a parametric positioning method on a continuous crystal detector. Three different models for the light distribution were tested. Diagnosis of the residues showed that the parametric model fits the experimental data better than Gaussian and Cauchy models in our particular experimental setup. Based on the correlation between the spread and the peak value of the light distribution model with the depth of interaction (DOI), we were able to estimate the three-dimensional position of a scintillation event. On our continuous miniature crystal element (cMiCE) detector module with 8 mm thick LYSO crystal, the intrinsic spatial resolution is 1.06 mm at the center and 1.27 mm at the corner using a maximum-likelihood estimation (MLE) method and the parametric model. The DOI resolution (full width at half maximum) is estimated to be approximately 3.24 mm. The positioning method using the parametric model outperformed the Gaussian and Cauchy models, in both MLE and weighted least-squares (WLS) fitting methods. The key feature of this technique is that it requires very little calibration of the detector, but still retains high resolution and high sensitivity.

Entities:  

Mesh:

Year:  2008        PMID: 18364542      PMCID: PMC2683022          DOI: 10.1088/0031-9155/53/7/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  An evaluation of a two-dimensional array detector for high resolution PET.

Authors:  M Dahlbom; E J Hoffman
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

4.  A full-field modular gamma camera.

Authors:  T D Milster; J N Aarsvold; H H Barrett; A L Landesman; L S Mar; D D Patton; T J Roney; R K Rowe; R H Seacat
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

5.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  5 in total
  6 in total

1.  Performance Evaluation of Small Animal PET Scanners With Different System Designs.

Authors:  Xiaoli Li; Adam M Alessio; Thompson H Burnett; Thomas K Lewellen; Roberts Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

2.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

3.  Characterization of highly multiplexed monolithic PET / gamma camera detector modules.

Authors:  L A Pierce; S Pedemonte; D DeWitt; L MacDonald; W C J Hunter; K Van Leemput; R Miyaoka
Journal:  Phys Med Biol       Date:  2018-03-29       Impact factor: 3.609

4.  Characterization or Monolithic Scintillation Detectors Etched with Laser Induced Optical Barriers.

Authors:  J V Panetta; S Surti; B Singh; J S Karp
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-10-10

5.  Evaluation of event position reconstruction in monolithic crystals that are optically coupled.

Authors:  M Morrocchi; W C J Hunter; A Del Guerra; T K Lewellen; P E Kinahan; L R MacDonald; M G Bisogni; R S Miyaoka
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

Review 6.  Recent development in PET instrumentation.

Authors:  By Hao Peng; Craig S Levin
Journal:  Curr Pharm Biotechnol       Date:  2010-09-01       Impact factor: 2.837

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.