Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.

Xiaoli Li1, Cate Lockhart, Tom K Lewellen, Robert S Miyaoka.   

Abstract

The spatial resolution performance characteristics of a monolithic crystal PET detector utilizing a sensor on the entrance surface (SES) design is reported. To facilitate this design, we propose to utilize a 2D silicon photomultiplier (SiPM) array device. Using a multi-step simulation process, we investigated the performance of a monolithic crystal PET detector with different data readout schemes and different SiPM parameters. The detector simulated was a 49.2mm by 49.2mm by 15mm LYSO crystal readout by a 12 by 12 array of 3.8mm by 3.8mm SiPM elements. A statistics based positioning (SBP) method was used for event positioning and depth of interaction (DOI) decoding. Although individual channel readout provided better spatial resolution, row-column summing is proposed to reduce the number of readout channels. The SiPM parameters investigated include photon detection efficiency (PDE) and gain variability between different channels; PDE and gain instability; and dark count noise. Of the variables investigated, the PDE shift of -3.2±0.7% and gain shift of -4±0.9% between detector testing and detector calibration had the most obvious impact on the detector performance, since it not only degraded the spatial resolution but also led to bias in positioning, especially at the edges of the crystal. The dark count noise also had an impact on the intrinsic spatial resolution. No data normalization is required for PDE variability of up to 12% FWHM and gain variability of up to 15% FWHM between SiPM channels. Based upon these results, a row-column summing readout scheme without data normalization will be used. Further, we plan to cool our detectors below room temperature to reduce dark count noise and to actively control the temperature of the SiPMs to reduce drifts in PDE and gain.

Entities:  

Year:  2011        PMID: 22685348      PMCID: PMC3368805          DOI: 10.1109/TNS.2011.2119378

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  8 in total

1.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

2.  A novel, SiPM-array-based, monolithic scintillator detector for PET.

Authors:  Dennis R Schaart; Herman T van Dam; Stefan Seifert; Ruud Vinke; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

3.  Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.

Authors:  Marnix C Maas; Dennis R Schaart; D J Jan van der Laan; Peter Bruyndonckx; Cedric Lemaître; Freek J Beekman; Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

4.  A high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability.

Authors:  Xiaoli Li; Cate Lockhart; Tom K Lewellen; Robert S Miyaoka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

5.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

6.  New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

7.  Measured Temperature Dependence of Scintillation Camera Signals Read Out by Geiger-Müller Mode Avalanche Photodiodes.

Authors:  William C J Hunter; Robert S Miyaoka; L R Macdonald; Thomas K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

8.  Calibration Method for ML Estimation of 3D Interaction Position in a Thick Gamma-Ray Detector.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

  8 in total
  4 in total

1.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

2.  Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs.

Authors:  Xiaoli Li; William C J Hunter; Tom K Lewellen; Robert S Miyaoka
Journal:  IEEE Trans Nucl Sci       Date:  2012       Impact factor: 1.679

3.  Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT.

Authors:  Marcelo A Queiroz; Gaspar Delso; Scott Wollenweber; Timothy Deller; Konstantinos Zeimpekis; Martin Huellner; Felipe de Galiza Barbosa; Gustav von Schulthess; Patrick Veit-Haibach
Journal:  PLoS One       Date:  2015-07-06       Impact factor: 3.240

4.  An edge-readout, multilayer detector for positron emission tomography.

Authors:  Xin Li; Maria Ruiz-Gonzalez; Lars R Furenlid
Journal:  Med Phys       Date:  2018-05-06       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.