A novel, SiPM-array-based, monolithic scintillator detector for PET.

Dennis R Schaart1, Herman T van Dam, Stefan Seifert, Ruud Vinke, Peter Dendooven, Herbert Löhner, Freek J Beekman.   

Abstract

Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce(3+) crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an approximately 0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 degrees , demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF(2) detector, equals 960 ps FWHM.

Entities:  

Mesh:

Year:  2009        PMID: 19443953     DOI: 10.1088/0031-9155/54/11/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  38 in total

1.  Intrinsic spatial resolution evaluation of the X'tal cube PET detector based on a 3D crystal block segmented by laser processing.

Authors:  Eiji Yoshida; Hideaki Tashima; Naoko Inadama; Fumihiko Nishikido; Takahiro Moriya; Tomohide Omura; Mitsuo Watanabe; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2012-07-11

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  A Prototype Detector for a Novel High-Resolution PET System: BazookaPET.

Authors:  Ryeojin Park; Brian W Miller; Abhinav K Jha; Lars R Furenlid; William C J Hunter; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2012 Oct-Nov

Review 4.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

Review 5.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

6.  Basic performance of a large area PET detector with a monolithic scintillator.

Authors:  Eiji Yoshida; Naoko Inadama; Hiroto Osada; Hideyuki Kawai; Fumihiko Nishikido; Hideo Murayama; Tomoaki Tsuda; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2011-02-22

7.  Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs.

Authors:  Robert S Miyaoka; Xiaoli Li; Cate Lockhart; Tom K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

8.  Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.

Authors:  Jung Yeol Yeom; Ruud Vinke; Craig S Levin
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

9.  Effect of CZT system characteristics on Compton scatter event recovery.

Authors:  Sheng Yang; Mohan Li; Michael Reed; James Hugg; Henry Chen; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-06

10.  Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics.

Authors:  Yiping Shao; Xishan Sun; Kejian A Lan; Chad Bircher; Kai Lou; Zhi Deng
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609