Abstract

In this work we investigate how the intrinsic spatial resolution varies with the number of digitized readout channels for a 64 (8×8) channel detector using a statistics-based positioning algorithm. We report results for both 6 mm and 8 mm thick crystals. Three channel reduction schemes are explored. The simplest scheme is row and column summing (R-C sum) of the photomultiplier tube channels. The second method is to only use channels with signals above a 1% threshold of the total signal (1% thres). The third method is to acquire a subset of PMT channels determined by the maximum signal channel (zone mask). The full width at half maximum (FWHM) intrinsic spatial resolution results for the central and corner sections of the detector are presented for each of the methods. All methods except R-C sum performed well for the central section of the detector. The 1% thres and zone mask schemes showed significant improvement for the corner section of the 6 mm thick crystal. All methods using a single depth look-up table had difficulty in the corner region for the 8 mm thick crystal. We believe this is caused by depth dependent edge effects on the light response function. Initial results using a depth dependent look-up table show improved positioning performance.

Entities:  

Year:  2007        PMID: 19180248      PMCID: PMC2632547          DOI: 10.1109/TNS.2007.905164

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  4 in total

1.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  A full-field modular gamma camera.

Authors:  T D Milster; J N Aarsvold; H H Barrett; A L Landesman; L S Mar; D D Patton; T J Roney; R K Rowe; R H Seacat
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

4.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  4 in total
  3 in total

1.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

2.  Characterization of highly multiplexed monolithic PET / gamma camera detector modules.

Authors:  L A Pierce; S Pedemonte; D DeWitt; L MacDonald; W C J Hunter; K Van Leemput; R Miyaoka
Journal:  Phys Med Biol       Date:  2018-03-29       Impact factor: 3.609

3.  Resolution Properties of a Prototype Continuous Miniature Crystal Element (cMiCE) Scanner.

Authors:  Robert S Miyaoka; Xiaoli Li; William Hunter; Larry A Pierce; Wendy McDougald; Paul E Kinahan; Thomas K Lewellen
Journal:  IEEE Trans Nucl Sci       Date:  2011-10       Impact factor: 1.679

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.