Literature DB >> 24845340

Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry.

H S Shin1, K C Nam, H Park, H U Choi, H Y Kim, C S Park.   

Abstract

OBJECTIVES: We compared the effective dose from panoramic radiography with that from cone beam CT (CBCT) using dose area product under adult and child exposure conditions.
METHODS: The effective doses of the cephalo, panorama, implant and dental modes of Alphard 3030 (Asahi Roentgen Ind., Co. Ltd, Kyoto, Japan) CBCT and the Jaw, Wide, Facial and temporomandibular joint modes of Rayscan Symphony (RAY Co., Ltd, Hwaseong, Republic of Korea) CBCT were compared with those of CRANEX(®) 3+ CEPH (Soredex Orion Corporation, Helsinki, Finland) panoramic radiography equipment under adult and child exposure conditions. Each effective dose was calculated using a conversion formula from dose area product meter measured values (VacuTec Messtechnik GmbH, Dresden, Germany). The conversion formulae used were suggested by Helmrot and Alm Carlsson and Batista et al, and they were applied with the tube voltage taken into consideration.
RESULTS: The maximum effective doses from the Alphard 3030 and Rayscan Symphony were 67 and 21 times greater than that from panoramic radiography, respectively. The ratios of the effective dose under the child setting to that under the adult condition were 0.60-0.62 and 0.84-0.95, and the maximum differences in effective doses between the adult and child exposure settings were equivalent to 27 and 4 times greater than a panoramic examination in the Alphard 3030 and Rayscan Symphony, respectively.
CONCLUSIONS: The effective CBCT doses were higher than those of panoramic radiography. The differences in effective doses between the adult and child CBCT settings were dependent on equipment type and exposure parameters. Therefore, adequate mode selection and control of exposure as well as further research are necessary to minimize the effective dose to patients, especially for radiosensitive children.

Entities:  

Keywords:  CBCT (cone beam CT); DAP (dose area product); ICRP; conversion factor; effective dose

Mesh:

Year:  2014        PMID: 24845340      PMCID: PMC4082268          DOI: 10.1259/dmfr.20130439

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  11 in total

1.  Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks
Journal:  Dentomaxillofac Radiol       Date:  2003-07       Impact factor: 2.419

2.  Effective doses in panoramic images from conventional and CBCT equipment.

Authors:  W O G Batista; M V T Navarro; A F Maia
Journal:  Radiat Prot Dosimetry       Date:  2011-12-14       Impact factor: 0.972

3.  A comparative study of the effective radiation doses from cone beam computed tomography and plain radiography for sialography.

Authors:  F Jadu; M J Yaffe; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

4.  Suggested diagnostic reference levels for paediatric X-ray examinations in India.

Authors:  A U Sonawane; J V K Sunil Kumar; Meghraj Singh; A S Pradhan
Journal:  Radiat Prot Dosimetry       Date:  2010-12-08       Impact factor: 0.972

5.  Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms.

Authors:  C Theodorakou; A Walker; K Horner; R Pauwels; R Bogaerts; R Jacobs
Journal:  Br J Radiol       Date:  2012-02       Impact factor: 3.039

6.  Effective dose from cone beam CT examinations in dentistry.

Authors:  J A Roberts; N A Drage; J Davies; D W Thomas
Journal:  Br J Radiol       Date:  2008-10-13       Impact factor: 3.039

7.  Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.

Authors:  John B Ludlow; Marija Ivanovic
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-05-27

8.  The use of cone-beam computed tomography in dentistry: an advisory statement from the American Dental Association Council on Scientific Affairs.

Authors: 
Journal:  J Am Dent Assoc       Date:  2012-08       Impact factor: 3.634

9.  Measurement of radiation dose in dental radiology.

Authors:  Ebba Helmrot; Gudrun Alm Carlsson
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

10.  Calculation of effective dose.

Authors:  C H McCollough; B A Schueler
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

View more
  18 in total

1.  Dose optimization for assessment of periodontal structures in cone beam CT examinations.

Authors:  Ayman Al-Okshi; Chrysoula Theodorakou; Christina Lindh
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

2.  Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Authors:  Husniye Demirturk Kocasarac; Dilek Helvacioglu Yigit; Boulos Bechara; Alper Sinanoglu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2016-03-08       Impact factor: 2.419

3.  Interrelationship of clinical, radiographic and haematological features in patients under bisphosphonate therapy.

Authors:  Valesca S Koth; Maria A Figueiredo; Fernanda G Salum; Karen Cherubini
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

4.  Presurgical evaluation of bony implant sites using panoramic radiography and cone beam computed tomography-influence of medical education.

Authors:  Michael Dau; Amir Edalatpour; Ralf Schulze; Bilal Al-Nawas; Abdulmonem Alshihri; Peer W Kämmerer
Journal:  Dentomaxillofac Radiol       Date:  2016-10-19       Impact factor: 2.419

Review 5.  Clinical guidelines for dental cone-beam computed tomography.

Authors:  Takafumi Hayashi; Yoshinori Arai; Toru Chikui; Sachiko Hayashi-Sakai; Kazuya Honda; Hiroko Indo; Taisuke Kawai; Kaoru Kobayashi; Shumei Murakami; Masako Nagasawa; Munetaka Naitoh; Eiji Nakayama; Yutaka Nikkuni; Hideyoshi Nishiyama; Noriaki Shoji; Shigeaki Suenaga; Ray Tanaka
Journal:  Oral Radiol       Date:  2018-01-11       Impact factor: 1.852

Review 6.  A review of dental cone-beam CT dose conversion coefficients.

Authors:  Eugene Mah; E Russell Ritenour; Hai Yao
Journal:  Dentomaxillofac Radiol       Date:  2020-11-11       Impact factor: 2.419

7.  Comparison of the performances of low-crystalline carbonate apatite and Bio-Oss in sinus augmentation using three-dimensional image analysis.

Authors:  Koudai Nagata; Kei Fuchigami; Ryoji Kitami; Yurie Okuhama; Kana Wakamori; Hirokazu Sumitomo; Hyunjin Kim; Manabu Okubo; Hiromasa Kawana
Journal:  Int J Implant Dent       Date:  2021-03-23

Review 8.  Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review.

Authors:  Burkhard Kunzendorf; Hendrik Naujokat; Jörg Wiltfang
Journal:  Int J Implant Dent       Date:  2021-05-27

9.  Clinically applicable artificial intelligence system for dental diagnosis with CBCT.

Authors:  Matvey Ezhov; Maxim Gusarev; Maria Golitsyna; Julian M Yates; Evgeny Kushnerev; Dania Tamimi; Secil Aksoy; Eugene Shumilov; Alex Sanders; Kaan Orhan
Journal:  Sci Rep       Date:  2021-07-22       Impact factor: 4.379

10.  Optimization of X-ray Investigations in Dentistry Using Optical Coherence Tomography.

Authors:  Ralph-Alexandru Erdelyi; Virgil-Florin Duma; Cosmin Sinescu; George Mihai Dobre; Adrian Bradu; Adrian Podoleanu
Journal:  Sensors (Basel)       Date:  2021-07-02       Impact factor: 3.847

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.