Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Husniye Demirturk Kocasarac1, Dilek Helvacioglu Yigit2, Boulos Bechara3, Alper Sinanoglu1, Marcel Noujeim3.   

Abstract

OBJECTIVES: To compare the contrast-to-noise ratio (CNR) of multiple acquisition settings for four types of retrograde filling materials in CBCT images taken for endodontic surgery follow-up.
METHODS: 20 maxillary central incisors were endodontically treated and obturated with 4 different root-end filling materials: amalgam, mineral trioxide aggregate, SuperEBA(™) (Harry J Bosworth Company, Skokie, IL) and Biodentine™ (Septodont, Saint-Maur-des-Faussés, France). Teeth were placed in a skull and scanned, one by one, with the Planmeca ProMax(®) 3D Max (Planmeca, Helsinki, Finland); at different voltages: 66, 76, 84 and 96 kVp; with low, normal and high resolution and high definition (HD); with and without metal artefact reduction (MAR). Images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the CNR. The dose-area product was registered, and the effective dose calculated.
RESULTS: No statistically significant difference was noted between the four materials. 84 and 96 kVp with low resolution and the use of MAR-generated images that have statistically better CNR than 66 and 76 kVp with HD, normal and high resolutions and without MAR. The use of low resolution also generated the smallest value of effective dose.
CONCLUSIONS: The best setting for radiographic follow-up in an endodontic surgery with retrograde filling on the Planmeca ProMax is 96 kVp with low resolution and high MAR; this setting produced one of the lowest effective doses.

Entities:  

Keywords:  cone beam computed tomography; contrast-to-noise ratio; endodontics; root canal filling materials; root-end filling material

Mesh:

Substances:

Year:  2016        PMID: 26954290      PMCID: PMC5084704          DOI: 10.1259/dmfr.20160012

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  29 in total

Review 1.  AAE and AAOMR Joint Position Statement: Use of Cone Beam Computed Tomography in Endodontics 2015 Update.

Authors: 
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2015-08-03

2.  Application- and patient size-dependent optimization of x-ray spectra for CT.

Authors:  Willi A Kalender; Paul Deak; Markus Kellermeier; Marcel van Straten; Sabrina V Vollmar
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Radiological assessment of the effects of potential root-end filling materials on healing after endodontic surgery.

Authors:  B S Chong; T R Ford; R F Wilson
Journal:  Endod Dent Traumatol       Date:  1997-08

4.  Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines.

Authors:  Boulos Bechara; Clyde A McMahan; William S Moore; Marcel Noujeim; Hassem Geha; Fabricio B Teixeira
Journal:  J Oral Sci       Date:  2012-09       Impact factor: 1.556

5.  Contrast-to-noise ratio with different large volumes in a cone-beam computerized tomography machine: an in vitro study.

Authors:  Boulos Bechara; C Alex McMahan; William S Moore; Marcel Noujeim; Hassem Geha
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2012-11

6.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

7.  Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry.

Authors:  H S Shin; K C Nam; H Park; H U Choi; H Y Kim; C S Park
Journal:  Dentomaxillofac Radiol       Date:  2014-03-10       Impact factor: 2.419

8.  Artefact expression associated with several cone-beam computed tomographic machines when imaging root filled teeth.

Authors:  K F Vasconcelos; L F P Nicolielo; M C Nascimento; F Haiter-Neto; F N Bóscolo; J Van Dessel; M EzEldeen; I Lambrichts; R Jacobs
Journal:  Int Endod J       Date:  2014-11-15       Impact factor: 5.264

9.  Measurement of radiation dose in dental radiology.

Authors:  Ebba Helmrot; Gudrun Alm Carlsson
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

10.  Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study.

Authors:  Boulos Bechara; C Alex McMahan; Ibrahim Nasseh; Hassem Geha; Elie Hayek; Georges Khawam; Michel Raad; Marcel Noujeim
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-05
View more
  9 in total

Review 1.  Biodentine™ material characteristics and clinical applications: a 3 year literature review and update.

Authors:  S Rajasekharan; L C Martens; R G E C Cauwels; R P Anthonappa
Journal:  Eur Arch Paediatr Dent       Date:  2018-01-25

2.  CBCT image artefacts generated by implants located inside the field of view or in the exomass.

Authors:  Husniye Demirturk Kocasarac; Lisa J Koenig; Gulbahar Ustaoglu; Matheus Lima Oliveira; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2021-07-29       Impact factor: 2.419

3.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

Review 4.  Etiology and Measurement of Peri-Implant Crestal Bone Loss (CBL).

Authors:  Adrien Naveau; Kouhei Shinmyouzu; Colman Moore; Limor Avivi-Arber; Jesse Jokerst; Sreenivas Koka
Journal:  J Clin Med       Date:  2019-02-01       Impact factor: 4.241

5.  Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study.

Authors:  Solaleh Shahmirzadi; Rana A Sharaf; Sarang Saadat; William S Moore; Hassem Geha; Dania Tamimi; Husniye Demirturk Kocasarac
Journal:  Imaging Sci Dent       Date:  2021-01-28

6.  Quantitative Analysis of Cone-Beam Computed Tomography Artifacts Induced by Nonmetallic Root Canal Filling Materials Using Different Fields of View: In Vitro Study.

Authors:  Rahaf A AlMohareb; Reem M Barakat; Mohamed Mehanny
Journal:  Scanning       Date:  2022-02-22       Impact factor: 1.932

7.  Estimation of contrast-to-noise ratio in CT and CBCT images with varying scan settings in presence of different implant materials.

Authors:  Emine Şebnem Kursun-Cakmak; Husniye Demirturk Kocasarac; Seval Bayrak; Gülbahar Ustaoğlu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2019-08-09       Impact factor: 2.419

8.  Modelling the skeletal muscle injury recovery using in vivo contrast-enhanced micro-CT: a proof-of-concept study in a rat model.

Authors:  Bruno Paun; Daniel García Leon; Alex Claveria Cabello; Roso Mares Pages; Elena de la Calle Vargas; Paola Contreras Muñoz; Vanessa Venegas Garcia; Joan Castell-Conesa; Mario Marotta Baleriola; Jose Raul Herance Camacho
Journal:  Eur Radiol Exp       Date:  2020-06-03

9.  Contrast-to-noise ratios of different dental restorative materials: an in-vitro cone beam computed tomography study.

Authors:  Seval Bayrak; Emine Sebnem Kursun Cakmak; Hakan Kamalak
Journal:  Eur Oral Res       Date:  2020-01-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.