Literature DB >> 22171097

Effective doses in panoramic images from conventional and CBCT equipment.

W O G Batista1, M V T Navarro, A F Maia.   

Abstract

Dental radiology is being extensively used especially after the consolidation of the dental implant technique. Although dental radiology has always been regarded as a low-dose technique, this scenario has changed with the introduction of volumetric techniques and consequent changes that have resulted from the use of the new technique. To compare dose values related to the use of different technologies used in the acquisition of dental panoramic images, the effective dose associated with this image technique was calculated using two different conversion factors for kerma-area product, P(KA), in the effective dose. Twenty-four pieces of equipment were evaluated and distributed into three categories: (1) 19 units of conventional equipment, (2) 3-cone beam computed tomography equipment (CBCT) which has a specific sensor to obtain panoramic images and (3) 2 items of CBCT equipment which only have sensors for volumetric acquisition, and the obtainment of panoramic images is through software reconstruction. The results show values of PKA and effective dose are higher for devices using digital image receptors. It is concluded that optimisation procedures and critical analysis should always be applied when adopting new technologies.

Mesh:

Year:  2011        PMID: 22171097     DOI: 10.1093/rpd/ncr454

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  8 in total

1.  Minimum size and positioning of imaging field for CBCT scans of impacted maxillary canines.

Authors:  Elmira Pakbaznejad Esmaeili; Anne-Mari Ilo; Janna Waltimo-Sirén; Marja Ekholm
Journal:  Clin Oral Investig       Date:  2019-06-24       Impact factor: 3.573

2.  Dose optimization for assessment of periodontal structures in cone beam CT examinations.

Authors:  Ayman Al-Okshi; Chrysoula Theodorakou; Christina Lindh
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

3.  Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry.

Authors:  H S Shin; K C Nam; H Park; H U Choi; H Y Kim; C S Park
Journal:  Dentomaxillofac Radiol       Date:  2014-03-10       Impact factor: 2.419

4.  Contrast-to-noise ratio with different settings in a CBCT machine in presence of different root-end filling materials: an in vitro study.

Authors:  Husniye Demirturk Kocasarac; Dilek Helvacioglu Yigit; Boulos Bechara; Alper Sinanoglu; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2016-03-08       Impact factor: 2.419

Review 5.  A review of dental cone-beam CT dose conversion coefficients.

Authors:  Eugene Mah; E Russell Ritenour; Hai Yao
Journal:  Dentomaxillofac Radiol       Date:  2020-11-11       Impact factor: 2.419

Review 6.  Comparison of conventional imaging techniques and CBCT for periodontal evaluation: A systematic review.

Authors:  Isabela Goulart Gil Choi; Arthur Rodriguez Gonzalez Cortes; Emiko Saito Arita; Marco Antonio Paupério Georgetti
Journal:  Imaging Sci Dent       Date:  2018-06-19

7.  A Comparison of Clinical and Radiological Parameters in the Evaluation of Molar Furcation Involvement in Periodontitis.

Authors:  Sanja Komšić; Darije Plančak; Adrian Kašaj; Ivan Puhar
Journal:  Acta Stomatol Croat       Date:  2019-12

8.  Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland.

Authors:  Marine Deleu; Dorothea Dagassan; Isabelle Berg; Julie Bize; Karl Dula; Vincent Lenoir; Barbara Ott; Julien G Ott; Francis R Verdun; Robert Weber; Panagiotis Ziglinas; Cesare Zingariello; Marta Sans Merce
Journal:  Dentomaxillofac Radiol       Date:  2020-04-17       Impact factor: 2.419

  8 in total