Ayman Al-Okshi1,2, Chrysoula Theodorakou3, Christina Lindh4. 1. 1 Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden. 2. 2 Department of Oral Medicine and Radiology, Faculty of Dentistry, Sebha University, Sebha, Libya. 3. 3 Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK. 4. 4 Faculty of Odontology, Malmö University, Malmö, Sweden.
Abstract
OBJECTIVES: To investigate the relationship between dose and image quality for a dedicated dental CBCT scanner using different scanning protocols and to set up an optimal imaging protocol for assessment of periodontal structures. METHODS: Radiation dose and image quality measurements were made using 3D Accuitomo 170 (J. Morita, Kyoto, Japan) dental CBCT scanner. The SedentexCT IQ phantom was used to investigate the relationship between contrast-to-noise ratio (CNR) and dose-area product. Subjective image quality assessment was achieved using a small adult skull phantom for the same range of exposure settings. Five independent observers assessed the images for three anatomical landmarks using a three-point visual grade analysis. RESULTS: When correlating the CNR of each scanning protocol to the exposure parameters used to obtain it, CNR decreased as these parameters decreased, especially current-exposure time product. When correlating to subjective image quality, the CNR level remained acceptable when 5 mA and 17.5 s or greater was selected and 80 kV could be used without compromising the CNR. CONCLUSIONS: For a dedicated CBCT unit, changing the rotation angle from 360° to 180° degrades image quality. By altering tube potential and current for the 360° rotation protocol, assessment of periodontal structures can be performed with a smaller dose without substantially affecting visualization.
OBJECTIVES: To investigate the relationship between dose and image quality for a dedicated dental CBCT scanner using different scanning protocols and to set up an optimal imaging protocol for assessment of periodontal structures. METHODS: Radiation dose and image quality measurements were made using 3D Accuitomo 170 (J. Morita, Kyoto, Japan) dental CBCT scanner. The SedentexCT IQ phantom was used to investigate the relationship between contrast-to-noise ratio (CNR) and dose-area product. Subjective image quality assessment was achieved using a small adult skull phantom for the same range of exposure settings. Five independent observers assessed the images for three anatomical landmarks using a three-point visual grade analysis. RESULTS: When correlating the CNR of each scanning protocol to the exposure parameters used to obtain it, CNR decreased as these parameters decreased, especially current-exposure time product. When correlating to subjective image quality, the CNR level remained acceptable when 5 mA and 17.5 s or greater was selected and 80 kV could be used without compromising the CNR. CONCLUSIONS: For a dedicated CBCT unit, changing the rotation angle from 360° to 180° degrades image quality. By altering tube potential and current for the 360° rotation protocol, assessment of periodontal structures can be performed with a smaller dose without substantially affecting visualization.
Authors: Ehsan Samei; Aldo Badano; Dev Chakraborty; Ken Compton; Craig Cornelius; Kevin Corrigan; Michael J Flynn; Bradley Hemminger; Nick Hangiandreou; Jeffrey Johnson; Donna M Moxley-Stevens; William Pavlicek; Hans Roehrig; Lois Rutz; Jeffrey Shepard; Robert A Uzenoff; Jihong Wang; Charles E Willis Journal: Med Phys Date: 2005-04 Impact factor: 4.071
Authors: Margarete B McGuigan; Christie Theodorakou; Henry F Duncan; Jonathan Davies; Anita Sengupta; Keith Horner Journal: Dentomaxillofac Radiol Date: 2020-06-22 Impact factor: 2.419
Authors: Amanda P Candemil; Benjamin Salmon; Karla F Vasconcelos; Anne C Oenning; Reinhilde Jacobs; Deborah Q Freitas; Francisco Haiter-Neto; Francesca Mangione; Matheus L Oliveira Journal: Sci Rep Date: 2021-09-27 Impact factor: 4.379