Literature DB >> 20587648

A comparative study of the effective radiation doses from cone beam computed tomography and plain radiography for sialography.

F Jadu1, M J Yaffe, E W N Lam.   

Abstract

OBJECTIVES: As a first step in developing a protocol for multidimensional sialography using cone beam CT (CBCT), the objective of this study was to compare the effective radiation doses from sialography of the parotid and submandibular glands using plain radiography and CBCT.
METHODS: The effective doses were calculated from dose measurements made at 25 selected locations in the head and neck of a radiation analogue dosimeter (RANDO) phantom, using International Commission on Radiological Protection 2007 tissue weighting factors.
RESULTS: The effective dose (E) changed in relationship to changes in CBCT field of view (FOV), peak kilovoltage (kVp) and milliamperage (mA). Specifically, E decreased from a maximum of 932 microSv (30 cm FOV, 120 kVp, 15 mA) to 60 microSv (15 cm FOV, 80 kVp, 10 mA) for a parotid gland study and to 148 microSv (15 cm FOV, 80 kVp, 10 mA) for a submandibular study. The collective series of plain radiographs made during sialography of the parotid and submandibular glands yielded effective doses of 65 microSv and 156 microSv, respectively. The plain parotid gland series included one panoramic, two anterior-posterior skull and four lateral skull radiographs, whereas the submandibular gland series included one panoramic, one standard mandibular occlusal and four lateral skull radiographs.
CONCLUSION: The effective doses from CBCT examinations centred on the parotid and submandibular glands were similar to those calculated for plain radiograph sialography when a 15 cm FOV was chosen in combination with exposure conditions of 80 kVp and 10 mA.

Mesh:

Year:  2010        PMID: 20587648      PMCID: PMC3520254          DOI: 10.1259/dmfr/62878962

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  16 in total

1.  Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography.

Authors:  D Schulze; M Heiland; H Thurmann; G Adam
Journal:  Dentomaxillofac Radiol       Date:  2004-03       Impact factor: 2.419

2.  1990 Recommendations of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1991

3.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks; W B Howerton
Journal:  Dentomaxillofac Radiol       Date:  2006-07       Impact factor: 2.419

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Ultrafast computed tomography and three-dimensional image processing of CT sialography in patients with parotid masses poorly defined by magnetic resonance imaging.

Authors:  D H Szolar; R Groell; H Braun; K Preidler; M Stiskal; R Kern; J Kainz; S Moelleken; H Stammberger
Journal:  Acta Otolaryngol       Date:  1996-01       Impact factor: 1.494

6.  Diagnostic X-ray exposure and female papillary thyroid cancer: a pooled analysis of two Swedish studies.

Authors:  G Wingren; A Hallquist; L Hardell
Journal:  Eur J Cancer Prev       Date:  1997-12       Impact factor: 2.497

7.  A prospective comparative study of MR sialography and conventional sialography of salivary duct disease.

Authors:  J C Varghese; F Thornton; B C Lucey; M Walsh; M A Farrell; M J Lee
Journal:  AJR Am J Roentgenol       Date:  1999-12       Impact factor: 3.959

8.  Sialolithiasis: MR sialography of the submandibular duct--an alternative to conventional sialography and US?

Authors:  L Jäger; F Menauer; N Holzknecht; V Scholz; G Grevers; M Reiser
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

9.  Parotid and submandibular calculi in children.

Authors:  L Bodner; D M Fliss
Journal:  Int J Pediatr Otorhinolaryngol       Date:  1995-01       Impact factor: 1.675

10.  Dental X-rays and the risk of intracranial meningioma: a population-based case-control study.

Authors:  W T Longstreth; Leslie E Phillips; Mark Drangsholt; Thomas D Koepsell; Brian S Custer; Jo-Ann Gehrels; Gerald van Belle
Journal:  Cancer       Date:  2004-03-01       Impact factor: 6.860

View more
  12 in total

1.  Optimization of exposure parameters for cone beam computed tomography sialography.

Authors:  F M Jadu; M L Hill; M J Yaffe; Ernest W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

2.  A comparative study of the diagnostic capabilities of 2D plain radiograph and 3D cone beam CT sialography.

Authors:  F M Jadu; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry.

Authors:  H S Shin; K C Nam; H Park; H U Choi; H Y Kim; C S Park
Journal:  Dentomaxillofac Radiol       Date:  2014-03-10       Impact factor: 2.419

4.  Three-dimensional cone-beam CT sialography in non tumour salivary pathologies: procedure and results.

Authors:  Hélios Bertin; Raphael Bonnet; Anne-Sophie Delemazure; Emmanuelle Mourrain-Langlois; Jacques Mercier; Pierre Corre
Journal:  Dentomaxillofac Radiol       Date:  2016-09-23       Impact factor: 2.419

5.  3D cephalometry on reduced FOV CBCT: skeletal class assessment through AF-BF on Frankfurt plane-validity and reliability through comparison with 2D measurements.

Authors:  Marco Farronato; Cinzia Maspero; Andrea Abate; Cristina Grippaudo; Stephen Thaddeus Connelly; Gianluca Martino Tartaglia
Journal:  Eur Radiol       Date:  2020-05-07       Impact factor: 5.315

6.  Small field of view cone beam CT temporomandibular joint imaging dosimetry.

Authors:  T D Lukat; J C M Wong; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2013-09-18       Impact factor: 2.419

7.  Advances in imaging of obstructed salivary glands can improve diagnostic outcomes.

Authors:  B Sobrino-Guijarro; L Cascarini; R K Lingam
Journal:  Oral Maxillofac Surg       Date:  2012-05-05

8.  Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

Authors:  Lienard A Chang; Donald L Miller; Choonsik Lee; Dunstana R Melo; Daphnée Villoing; Vladimir Drozdovitch; Isabelle Thierry-Chef; Sarah J Winters; Michael Labrake; Charles F Myers; Hyeyeun Lim; Cari M Kitahara; Martha S Linet; Steven L Simon
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

Review 9.  Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units.

Authors:  J B Ludlow; R Timothy; C Walker; R Hunter; E Benavides; D B Samuelson; M J Scheske
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

10.  Assessment of the role of cone beam computed sialography in diagnosing salivary gland lesions.

Authors:  Nagla'a Abdel-Wahed; Maha E Amer; Noha Saleh Mahmoud Abo-Taleb
Journal:  Imaging Sci Dent       Date:  2013-03-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.