Literature DB >> 18852212

Effective dose from cone beam CT examinations in dentistry.

J A Roberts1, N A Drage, J Davies, D W Thomas.   

Abstract

Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. In particular, the i-CAT CBCT scanner was investigated for several imaging protocols commonly used in clinical practice. A Rando phantom containing thermoluminescent dosemeters was scanned. Using both the 1990 and recently approved 2007 International Commission on Radiological Protection recommended tissue weighting factors, effective doses were calculated. The doses (E(1990), E(2007)) were: full FOV head (92.8 microSv, 206.2 microSv); 13 cm scan of the jaws (39.5 microSv, 133.9 microSv); 6 cm high-resolution mandible (47.2 microSv, 188.5 microSv); 6 cm high-resolution maxilla (18.5 microSv, 93.3 microSv); 6 cm standard mandible (23.9 microSv, 96.2 microSv); and 6 cm standard maxilla (9.7 microSv, 58.9 microSv). The doses from CBCT are low compared with conventional CT but significantly higher than conventional dental radiography techniques.

Entities:  

Mesh:

Year:  2008        PMID: 18852212     DOI: 10.1259/bjr/31419627

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  73 in total

1.  Necessity of 3D visualization for the removal of lower wisdom teeth: required sample size to prove non-inferiority of panoramic radiography compared to CBCT.

Authors:  Felix Roeder; Daniel Wachtlin; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2011-04-26       Impact factor: 3.573

2.  Effective doses from cone beam CT investigation of the jaws.

Authors:  J Davies; B Johnson; Na Drage
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

3.  Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars.

Authors:  X M Qu; G Li; G C H Sanderink; Z Y Zhang; X C Ma
Journal:  Dentomaxillofac Radiol       Date:  2012-07       Impact factor: 2.419

4.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

5.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

Review 6.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

7.  Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms.

Authors:  C Theodorakou; A Walker; K Horner; R Pauwels; R Bogaerts; R Jacobs
Journal:  Br J Radiol       Date:  2012-02       Impact factor: 3.039

8.  Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics.

Authors:  Luca Signorelli; Raphael Patcas; Timo Peltomäki; Marc Schätzle
Journal:  J Orofac Orthop       Date:  2016-01-08       Impact factor: 1.938

9.  Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

Authors:  Anna Kelaranta; Marja Ekholm; Paula Toroi; Mika Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2015-08-27       Impact factor: 2.419

10.  Presurgical evaluation of bony implant sites using panoramic radiography and cone beam computed tomography-influence of medical education.

Authors:  Michael Dau; Amir Edalatpour; Ralf Schulze; Bilal Al-Nawas; Abdulmonem Alshihri; Peer W Kämmerer
Journal:  Dentomaxillofac Radiol       Date:  2016-10-19       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.