Literature DB >> 23104003

Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior.

Jianhua Ma1, Hua Zhang, Yang Gao, Jing Huang, Zhengrong Liang, Qianjing Feng, Wufan Chen.   

Abstract

Cerebral perfusion x-ray computed tomography (PCT) imaging, which detects and characterizes the ischemic penumbra, and assesses blood-brain barrier permeability with acute stroke or chronic cerebrovascular diseases, has been developed extensively over the past decades. However, due to its sequential scan protocol, the associated radiation dose has raised significant concerns to patients. Therefore, in this study we developed an iterative image reconstruction algorithm based on the maximum a posterior (MAP) principle to yield a clinically acceptable cerebral PCT image with lower milliampere-seconds (mA s). To preserve the edges of the reconstructed image, an edge-preserving prior was designed using a normal-dose pre-contrast unenhanced scan. For simplicity, the present algorithm was termed as 'MAP-ndiNLM'. Evaluations with the digital phantom and the simulated low-dose clinical brain PCT datasets clearly demonstrate that the MAP-ndiNLM method can achieve more significant gains than the existing FBP and MAP-Huber algorithms with better image noise reduction, low-contrast object detection and resolution preservation. More importantly, the MAP-ndiNLM method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the MAP-Huber method.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23104003      PMCID: PMC3498910          DOI: 10.1088/0031-9155/57/22/7519

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA.

Authors:  Yoshimasa Imanishi; Atsushi Fukui; Hiroshi Niimi; Daisuke Itoh; Kyouko Nozaki; Shunsuke Nakaji; Kumiko Ishizuka; Hitoshi Tabata; Yu Furuya; Masahiko Uzura; Hideto Takahama; Suzuo Hashizume; Shiro Arima; Yasuo Nakajima
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

2.  Generalized Gibbs priors based positron emission tomography reconstruction.

Authors:  Jianhua Ma; Qianjin Feng; Yanqiu Feng; Jing Huang; Wufan Chen
Journal:  Comput Biol Med       Date:  2010-05-05       Impact factor: 4.589

3.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

4.  A generalized Gaussian image model for edge-preserving MAP estimation.

Authors:  C Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1993       Impact factor: 10.856

5.  An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.

Authors:  P Coupe; P Yger; S Prima; P Hellier; C Kervrann; C Barillot
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  4D micro-CT for cardiac and perfusion applications with view under sampling.

Authors:  Cristian T Badea; Samuel M Johnston; Yi Qi; G Allan Johnson
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

8.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

Authors:  D Fleischmann; G D Rubin; A A Bankier; K Hittmair
Journal:  Radiology       Date:  2000-02       Impact factor: 11.105

9.  Dynamic perfusion CT: optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients.

Authors:  Andreas Kämena; Florian Streitparth; Christian Grieser; Lukas Lehmkuhl; Basil Jamil; Katarzyna Wojtal; Jens Ricke; Maciej Pech
Journal:  Eur J Radiol       Date:  2007-03-23       Impact factor: 3.528

10.  FDA investigates the safety of brain perfusion CT.

Authors:  M Wintermark; M H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 4.966

View more
  44 in total

1.  Improving low-dose blood-brain barrier permeability quantification using sparse high-dose induced prior for Patlak model.

Authors:  Ruogu Fang; Kolbeinn Karlsson; Tsuhan Chen; Pina C Sanelli
Journal:  Med Image Anal       Date:  2013-10-17       Impact factor: 8.545

2.  Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction.

Authors:  Joris M Niesten; Irene C van der Schaaf; Alan J Riordan; Hugo W A M de Jong; Alexander D Horsch; Daniel Eijspaart; Ewoud J Smit; Willem P T M Mali; Birgitta K Velthuis
Journal:  Eur Radiol       Date:  2013-10-15       Impact factor: 5.315

3.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization. Part II: An adaptive approach.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; Yan Liu; Hao Han; Hongbing Lu; William Moore; Zhengrong Liang
Journal:  Comput Med Imaging Graph       Date:  2015-03-06       Impact factor: 4.790

4.  Low-dose CT via convolutional neural network.

Authors:  Hu Chen; Yi Zhang; Weihua Zhang; Peixi Liao; Ke Li; Jiliu Zhou; Ge Wang
Journal:  Biomed Opt Express       Date:  2017-01-09       Impact factor: 3.732

5.  [Influence of projection data correction on digital breast tomosynthesis imaging].

Authors:  Xin-Yu Zhang; Hua Zhang; Zhao-Ying Bian; Dong Zeng; Ji He; Xiu-Mei Tian; Jian-Hua Ma; Jing Huang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-03-20

6.  [Sinogram restoration for low-dose cerebral perfusion CT images].

Authors:  Xiu-Mei Tian; Jing Huang; Jia-Hui Lin; Xin-Yu Zhang; Jian-Hua Ma; Zhao-Ying Bian
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2016-04-20

7.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

8.  Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

9.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

10.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.