Literature DB >> 23470430

A limited-angle CT reconstruction method based on anisotropic TV minimization.

Zhiqiang Chen1, Xin Jin, Liang Li, Ge Wang.   

Abstract

This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize the balance between TV-based smoothing and data fidelity. In the case of the limited-angle CT problem, the strength of data consistency is angularly varying. For example, given a parallel beam of x-rays, information extracted in the Fourier domain is mostly orthogonal to the direction of x-rays, while little is probed otherwise. However, the TV minimization process is isotropic, suggesting that it is unfit for limited-angle CT. Here we introduce an anisotropic TV minimization method to address this challenge. The advantage of our approach is demonstrated in numerical simulation with both phantom and real CT images, relative to the TV-based reconstruction.

Entities:  

Mesh:

Year:  2013        PMID: 23470430     DOI: 10.1088/0031-9155/58/7/2119

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  Accelerated Stimulated Raman Projection Tomography by Sparse Reconstruction From Sparse-View Data.

Authors:  Xueli Chen; Shouping Zhu; Huiyuan Wang; Cuiping Bao; Defu Yang; Chi Zhang; Peng Lin; Ji-Xin Cheng; Yonghua Zhan; Jimin Liang; Jie Tian
Journal:  IEEE Trans Biomed Eng       Date:  2019-08-14       Impact factor: 4.538

2.  Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Authors:  Shanzhou Niu; Yang Gao; Zhaoying Bian; Jing Huang; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

Review 3.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

4.  LEARN: Learned Experts' Assessment-Based Reconstruction Network for Sparse-Data CT.

Authors:  Hu Chen; Yi Zhang; Yunjin Chen; Junfeng Zhang; Weihua Zhang; Huaiqiang Sun; Yang Lv; Peixi Liao; Jiliu Zhou; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

5.  Multi-energy CT reconstruction using tensor nonlocal similarity and spatial sparsity regularization.

Authors:  Wenkun Zhang; Ningning Liang; Zhe Wang; Ailong Cai; Linyuan Wang; Chao Tang; Zhizhong Zheng; Lei Li; Bin Yan; Guoen Hu
Journal:  Quant Imaging Med Surg       Date:  2020-10

6.  Minimizing L 1 over L 2 norms on the gradient.

Authors:  Chao Wang; Min Tao; Chen-Nee Chuah; James Nagy; Yifei Lou
Journal:  Inverse Probl       Date:  2022-05-06       Impact factor: 2.408

7.  An improved patch-based regularization method for PET image reconstruction.

Authors:  Juan Gao; Qiegen Liu; Chao Zhou; Weiguang Zhang; Qian Wan; Chenxi Hu; Zheng Gu; Dong Liang; Xin Liu; Yongfeng Yang; Hairong Zheng; Zhanli Hu; Na Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-02

8.  Image-domain Material Decomposition for Spectral CT using a Generalized Dictionary Learning.

Authors:  Weiwen Wu; Peijun Chen; Shaoyu Wang; Varut Vardhanabhuti; Fenglin Liu; Hengyong Yu
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-05-26

Review 9.  Advances in micro-CT imaging of small animals.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2021-07-17       Impact factor: 3.119

10.  CT brush and CancerZap!: two video games for computed tomography dose minimization.

Authors:  Graham Alvare; Richard Gordon
Journal:  Theor Biol Med Model       Date:  2015-05-12       Impact factor: 2.432

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.