Literature DB >> 24977611

Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

Yang Gao, Zhaoying Bian, Jing Huang, Yunwan Zhang, Shanzhou Niu, Qianjin Feng, Wufan Chen, Zhengrong Liang, Jianhua Ma.   

Abstract

To realize low-dose imaging in X-ray computed tomography (CT) examination, lowering milliampere-seconds (low-mAs) or reducing the required number of projection views (sparse-view) per rotation around the body has been widely studied as an easy and effective approach. In this study, we are focusing on low-dose CT image reconstruction from the sinograms acquired with a combined low-mAs and sparse-view protocol and propose a two-step image reconstruction strategy. Specifically, to suppress significant statistical noise in the noisy and insufficient sinograms, an adaptive sinogram restoration (ASR) method is first proposed with consideration of the statistical property of sinogram data, and then to further acquire a high-quality image, a total variation based projection onto convex sets (TV-POCS) method is adopted with a slight modification. For simplicity, the present reconstruction strategy was termed as "ASR-TV-POCS." To evaluate the present ASR-TV-POCS method, both qualitative and quantitative studies were performed on a physical phantom. Experimental results have demonstrated that the present ASR-TV-POCS method can achieve promising gains over other existing methods in terms of the noise reduction, contrast-to-noise ratio, and edge detail preservation.

Entities:  

Mesh:

Year:  2014        PMID: 24977611      PMCID: PMC4083059          DOI: 10.1364/OE.22.015190

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  23 in total

1.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

2.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Wavelet based noise reduction in CT-images using correlation analysis.

Authors:  Anja Borsdorf; Rainer Raupach; Thomas Flohr; Joachim Hornegger
Journal:  IEEE Trans Med Imaging       Date:  2008-12       Impact factor: 10.048

5.  Iterative image reconstruction for CBCT using edge-preserving prior.

Authors:  Jing Wang; Tianfang Li; Lei Xing
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

7.  Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Authors:  Shanzhou Niu; Yang Gao; Zhaoying Bian; Jing Huang; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

8.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

Review 9.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

10.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography.

Authors:  Andrew J Einstein; Milena J Henzlova; Sanjay Rajagopalan
Journal:  JAMA       Date:  2007-07-18       Impact factor: 56.272

View more
  10 in total

1.  [Sinogram restoration for low-dose cerebral perfusion CT images].

Authors:  Xiu-Mei Tian; Jing Huang; Jia-Hui Lin; Xin-Yu Zhang; Jian-Hua Ma; Zhao-Ying Bian
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2016-04-20

Review 2.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

3.  [Total generalized variation minimization based on projection data for low?dose CT reconstruction].

Authors:  Shan-Zhou Niu; Heng Wu; Ze-Feng Yu; Zi-Jun Zheng; Gao-Hang Yu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

4.  [Sparse-view helical CT reconstruction based on tensor total generalized variation minimization].

Authors:  Gaofeng Chen; Yongbo Wang; Zhaoying Bian; Ziquan Wei; Yaohong Deng; Mingqiang Li; Kun Ma; Xi Tao; Bin Li; Jianhua Ma; Jing Huang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-10-30

5.  A new Mumford-Shah total variation minimization based model for sparse-view x-ray computed tomography image reconstruction.

Authors:  Bo Chen; Zhaoying Bian; Xiaohui Zhou; Wensheng Chen; Jianhua Ma; Zhengrong Liang
Journal:  Neurocomputing       Date:  2018-02-17       Impact factor: 5.719

6.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

7.  Robust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating Mechanism.

Authors:  Qi Xie; Dong Zeng; Qian Zhao; Deyu Meng; Zongben Xu; Zhengrong Liang; Jianhua Ma
Journal:  IEEE Trans Med Imaging       Date:  2017-12       Impact factor: 10.048

8.  Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties.

Authors:  Soo Mee Kim; Adam M Alessio; Bruno De Man; Paul E Kinahan
Journal:  IEEE Trans Nucl Sci       Date:  2017-01-17       Impact factor: 1.679

9.  Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT.

Authors:  Haewon Nam; Minghao Guo; Hengyong Yu; Keumsil Lee; Ruijiang Li; Bin Han; Lei Xing; Rena Lee; Hao Gao
Journal:  PLoS One       Date:  2019-01-11       Impact factor: 3.240

10.  Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

Authors:  Hsuan-Ming Huang; Ing-Tsung Hsiao
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.