Improvements in the application and reporting of advanced Bland-Altman methods of comparison.

Erik Olofsen1, Albert Dahan, Gerard Borsboom, Gordon Drummond.   

Abstract

Bland and Altman have developed a measure called "limits of agreement" to assess correspondence of two methods of clinical measurement. In many circumstances, comparisons are made using several paired measurements in each individual subject. If such measurements are considered as statistically independent pairs, rather than as sets of measurements from separate individuals, limits of agreement will be too narrow. In addition, the confidence intervals for these limits will also be too narrow. Suitable software to compute valid limits of agreement and their confidence intervals is not readily available. Therefore, we set out to provide a freely available implementation accompanied by a formal description of the more advanced Bland-Altman comparison methods. We validate the implementation using simulated data, and demonstrate the effects caused by failing to take the presence of multiple paired measurements per individual properly into account. We propose a standard format of reporting that would improve analysis and interpretation of comparison studies.

Mesh:

Year:  2014        PMID: 24806333     DOI: 10.1007/s10877-014-9577-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  15 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Comparing methods of clinical measurement: reporting standards for bland and altman analysis.

Authors:  S Mantha; M F Roizen; L A Fleisher; R Thisted; J Foss
Journal:  Anesth Analg       Date:  2000-03       Impact factor: 5.108

Review 3.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

4.  A note on the analysis of repeated measurements of the same subjects.

Authors:  P D OLDHAM
Journal:  J Chronic Dis       Date:  1962-10

5.  Closed-form confidence intervals for functions of the normal mean and standard deviation.

Authors:  Allan Donner; G Y Zou
Journal:  Stat Methods Med Res       Date:  2010-09-08       Impact factor: 3.021

6.  Agreement between methods of measurement with multiple observations per individual.

Authors:  J Martin Bland; Douglas G Altman
Journal:  J Biopharm Stat       Date:  2007       Impact factor: 1.051

7.  Using the Bland-Altman method to measure agreement with repeated measures.

Authors:  P S Myles; J Cui
Journal:  Br J Anaesth       Date:  2007-09       Impact factor: 9.166

8.  Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual.

Authors:  G Y Zou
Journal:  Stat Methods Med Res       Date:  2011-06-24       Impact factor: 3.021

9.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

10.  Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery.

Authors:  Gianni Biancofiore; Lester A H Critchley; Anna Lee; Xiao-xing Yang; Lucia M Bindi; Massimo Esposito; Massimo Bisà; Luca Meacci; Roberto Mozzo; Franco Filipponi
Journal:  Anesth Analg       Date:  2011-06-16       Impact factor: 5.108

View more
  19 in total

1.  Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?

Authors:  Huang Li; Lester A H Critchley; Jie Zhang
Journal:  J Clin Monit Comput       Date:  2015-08-28       Impact factor: 2.502

2.  Intercomparison of airborne multi-angle polarimeter observations from the Polarimeter Definition Experiment.

Authors:  Kirk Knobelspiesse; Qian Tan; Carol Bruegge; Brian Cairns; Jacek Chowdhary; Bastiaan van Diedenhoven; David Diner; Richard Ferrare; Gerard van Harten; Veljko Jovanovic; Matteo Ottaviani; Jens Redemann; Felix Seidel; Kenneth Sinclair
Journal:  Appl Opt       Date:  2019-01-20       Impact factor: 1.980

3.  Identifying the position of the right atrium to align pressure transducer for CVP : Spirit level or 3D electromagnetic positioning?

Authors:  S Avellan; I Uhr; D McKelvey; Soren Sondergaard
Journal:  J Clin Monit Comput       Date:  2016-08-10       Impact factor: 2.502

4.  A standardized framework for testing the performance of sleep-tracking technology: step-by-step guidelines and open-source code.

Authors:  Luca Menghini; Nicola Cellini; Aimee Goldstone; Fiona C Baker; Massimiliano de Zambotti
Journal:  Sleep       Date:  2021-02-12       Impact factor: 5.849

5.  A Comparison of Inertial Measurement Unit and Motion Capture Measurements of Tibiofemoral Kinematics during Simulated Pivot Landings.

Authors:  So Young Baek; Mirel Ajdaroski; Payam Mirshams Shahshahani; Mélanie L Beaulieu; Amanda O Esquivel; James A Ashton-Miller
Journal:  Sensors (Basel)       Date:  2022-06-11       Impact factor: 3.847

6.  Sample size determination in method comparison and observer variability studies.

Authors:  Oke Gerke; Andreas Kristian Pedersen; Birgit Debrabant; Ulrich Halekoh; Sören Möller
Journal:  J Clin Monit Comput       Date:  2022-04-19       Impact factor: 1.977

7.  ClearSight™ finger cuff versus invasive arterial pressure measurement in patients with body mass index above 45 kg/m2.

Authors:  Victoria Eley; Rebecca Christensen; Louis Guy; Kerstin Wyssusek; Anita Pelecanos; Benjamin Dodd; Michael Stowasser; Andre van Zundert
Journal:  BMC Anesthesiol       Date:  2021-05-18       Impact factor: 2.217

8.  Sources of error with cardiovascular PET/CT and PET/MRI and questions to be answered to achieve clinical usefulness.

Authors:  Poul F Høilund-Carlsen; Oke Gerke
Journal:  J Nucl Cardiol       Date:  2021-07-21       Impact factor: 3.872

9.  Application of Mixed Effects Limits of Agreement in the Presence of Multiple Sources of Variability: Exemplar from the Comparison of Several Devices to Measure Respiratory Rate in COPD Patients.

Authors:  Richard A Parker; Christopher J Weir; Noah Rubio; Roberto Rabinovich; Hilary Pinnock; Janet Hanley; Lucy McCloughan; Ellen M Drost; Leandro C Mantoani; William MacNee; Brian McKinstry
Journal:  PLoS One       Date:  2016-12-14       Impact factor: 3.240

10.  The chinese version of achilles tendon total rupture score: cross-cultural adaptation, reliability and validity.

Authors:  Jin Cui; Zhenyu Jia; Xin Zhi; Xiaoqun Li; Xiao Zhai; Liehu Cao; Weizong Weng; Jun Zhang; Lin Wang; Xiao Chen; Jiacan Su
Journal:  Health Qual Life Outcomes       Date:  2017-01-05       Impact factor: 3.186

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.