Comparing methods of clinical measurement: reporting standards for bland and altman analysis.

S Mantha1, M F Roizen, L A Fleisher, R Thisted, J Foss.   

Abstract

UNLABELLED: In this era of medical technology assessment and evidence-based medicine, evaluating new methods to measure physiologic variables is facilitated by standardization of reporting results. It has been proposed that assessing repeatability be followed by assessing agreement with an established technique. If the "limits of agreement" (mean bias +/- 2SD) are not clinically important, then one could use two measurements interchangeably. Generalizability to larger populations is facilitated by reporting confidence intervals. We identified 44 studies that compared methods of clinical measurement published during 1996 to 1998 in seven anesthesia journals. Although 42 of 44 (95.4%) used the limits of agreement methodology for analysis, several inadequacies and inconsistencies in reporting the results were noted. Limits of agreement were defined a priori in 7.1%, repeatability was evaluated in 21.4%, and relationship (pattern) between difference and average was evaluated in 7.1%. Only one of the articles reported confidence intervals. A computer macro for the Minitab statistical package (State College, PA) is described to facilitate reporting of Bland and Altman analysis with confidence intervals. We propose standardization of nomenclature in clinical measurement comparison studies. IMPLICATIONS: A literature review of anesthesia journals revealed several inadequacies and inconsistencies in statistical reports of results of comparison studies with regard to interchangeability of measurement methods. We encourage journal editors to evaluate submissions on this subject carefully to ensure that their readers can draw valid conclusions about the value of new technologies.

Mesh:

Year:  2000        PMID: 10702443     DOI: 10.1097/00000539-200003000-00018

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  48 in total

1.  Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs.

Authors:  Paul D MacFarlane; Nicola Grint; Alexandra Dugdale
Journal:  Vet Res Commun       Date:  2010-03-23       Impact factor: 2.459

2.  Can measurements from an anteroposterior radiograph predict pelvic sagittal inclination?

Authors:  Keisuke Uemura; Penny R Atkins; Masashi Okamoto; Kunihiko Tokunaga; Andrew E Anderson
Journal:  J Orthop Res       Date:  2020-04-30       Impact factor: 3.494

3.  Measurement properties of the Work Limitations Questionnaire were sufficient among cancer survivors.

Authors:  Sietske J Tamminga; Jos H A M Verbeek; Monique H W Frings-Dresen; Angela G E M De Boer
Journal:  Qual Life Res       Date:  2013-07-27       Impact factor: 4.147

Review 4.  Design, analysis, and interpretation of method-comparison studies.

Authors:  Sandra K Hanneman
Journal:  AACN Adv Crit Care       Date:  2008 Apr-Jun

5.  Agreement of tricuspid annular systolic excursion measurement between transthoracic and transesophageal echocardiography in the perioperative setting.

Authors:  Anna Flo Forner; Elham Hasheminejad; Sergi Sabate; Michael A Ackermann; Edwin W Turton; Joerg Ender
Journal:  Int J Cardiovasc Imaging       Date:  2017-04-13       Impact factor: 2.357

6.  Study on accommodation by autorefraction and dynamic refraction in children.

Authors:  Prabhakar Srinivasapur Krishnacharya
Journal:  J Optom       Date:  2014-08-15

7.  Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound.

Authors:  Lin Yan; Yukun Luo; Jing Xiao; Lin Lin
Journal:  Eur Radiol       Date:  2020-10-31       Impact factor: 5.315

8.  Quantitative determination of valproic acid in postmortem blood samples--evidence of strong matrix dependency and instability.

Authors:  Verena Kiencke; Hilke Andresen-Streichert; Alexander Müller; Stefanie Iwersen-Bergmann
Journal:  Int J Legal Med       Date:  2013-03-28       Impact factor: 2.686

9.  Repeatability and reproducibility of the hyperinsulinemic-euglycemic clamp and the tracer dilution technique in a controlled inpatient setting.

Authors:  Duc Son N T Le; Thomas Brookshire; Jonathan Krakoff; Joy C Bunt
Journal:  Metabolism       Date:  2009-03       Impact factor: 8.694

10.  Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines.

Authors:  Wayne A Hing; Keith Rome; Alyse Fm Cameron
Journal:  J Foot Ankle Res       Date:  2009-11-16       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.