Literature DB >> 17613642

Agreement between methods of measurement with multiple observations per individual.

J Martin Bland1, Douglas G Altman.   

Abstract

Limits of agreement provide a straightforward and intuitive approach to agreement between different methods for measuring the same quantity. When pairs of observations using the two methods are independent, i.e., on different subjects, the calculations are very simple and straightforward. Some authors collect repeated data, either as repeated pairs of measurements on the same subject, whose true value of the measured quantity may be changing, or more than one measurement by one or both methods of an unchanging underlying quantity. In this paper we describe methods for analysing such clustered observations, both when the underlying quantity is assumed to be changing and when it is not.

Mesh:

Year:  2007        PMID: 17613642     DOI: 10.1080/10543400701329422

Source DB:  PubMed          Journal:  J Biopharm Stat        ISSN: 1054-3406            Impact factor:   1.051


  430 in total

1.  Comparison of SNAP™ II and BIS Vista indices during normothermic cardiopulmonary bypass under isoflurane anesthesia.

Authors:  Kinjal M Patel; Saadia S Sherwani; Paul C Fitzgerald; Robert J McCarthy
Journal:  J Clin Monit Comput       Date:  2011-11-11       Impact factor: 2.502

2.  Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry.

Authors:  Ron Dueck; Oliver Goedje; Paul Clopton
Journal:  J Clin Monit Comput       Date:  2012-01-18       Impact factor: 2.502

3.  Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography.

Authors:  Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2012-02-18       Impact factor: 2.502

4.  The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.

Authors:  Bernd Saugel; Florian Fassio; Alexander Hapfelmeier; Agnes S Meidert; Roland M Schmid; Wolfgang Huber
Journal:  Intensive Care Med       Date:  2012-06-29       Impact factor: 17.440

5.  The importance of using the correct bounds on the Bland-Altman limits of agreement when multiple measurements are recorded per patient.

Authors:  Cody Hamilton; Steven Lewis
Journal:  J Clin Monit Comput       Date:  2010-03-21       Impact factor: 2.502

6.  Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?

Authors:  Naka Imakiire; Takeshi Omae; Akira Matsunaga; Ryuzo Sakata; Yuichi Kanmura
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

7.  Assessing motivational interviewing integrity for group interventions with adolescents.

Authors:  Elizabeth J D'Amico; Karen C Osilla; Jeremy N V Miles; Brett Ewing; Kristen Sullivan; Kristin Katz; Sarah B Hunter
Journal:  Psychol Addict Behav       Date:  2012-05-28

8.  An autocalibrating algorithm for non-invasive cardiac output determination based on the analysis of an arterial pressure waveform recorded with radial artery applanation tonometry: a proof of concept pilot analysis.

Authors:  Bernd Saugel; Agnes S Meidert; Nicolas Langwieser; Julia Y Wagner; Florian Fassio; Alexander Hapfelmeier; Luisa M Prechtl; Wolfgang Huber; Roland M Schmid; Oliver Gödje
Journal:  J Clin Monit Comput       Date:  2013-12-10       Impact factor: 2.502

9.  Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

Authors:  E M Schrauben; K M Johnson; J Huston; A M Del Rio; S B Reeder; A Field; O Wieben
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

10.  Stability of FDG-PET Radiomics features: an integrated analysis of test-retest and inter-observer variability.

Authors:  Ralph T H Leijenaar; Sara Carvalho; Emmanuel Rios Velazquez; Wouter J C van Elmpt; Chintan Parmar; Otto S Hoekstra; Corneline J Hoekstra; Ronald Boellaard; André L A J Dekker; Robert J Gillies; Hugo J W L Aerts; Philippe Lambin
Journal:  Acta Oncol       Date:  2013-09-09       Impact factor: 4.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.