X ray storage performance of KCl:Eu2+ with high cumulated dose.

Rachael A Hansel1, Zhiyan Xiao1, Lei Zhang1, H Harold Li1.   

Abstract

The effects of high cumulative radiation dose on the luminescence properties of KCl:Eu2+ are investigated. Pellet samples of KCl:Eu2+ were given doses of up to 200 kGy at the Louisiana State University Synchrotron facility. After synchrotron irradiation, samples were optically bleached and given a clinical dose of 2 Gy from a 6 MV medical linear accelerator. Optical properties were evaluated using photostimulated luminescence (PSL), photoluminescence (PL), and temperature-dependent PSL measurements. For a cumulated dose of up to 5-10 kGy, the PSL emission intensity increased by 15% compared to the PSL signal with no radiation history. For doses higher than 10 kGy, the PSL emission intensity retained at least 70% of the original intensity. Spatial correlation of the charge storage centers increased for doses up to 5 kGy and then decreased for higher cumulative doses. Emission band at 975 nm was attributed to transitions of Eu1+. PL spectra showed an intense peak centered at 420 nm for all cumulative doses. The results of this work show that KCl:Eu2+ storage phosphors are excellent reusable materials for radiation therapy dosimetry.

Entities:  

Keywords:  KCl:Eu2+; Photostimulated luminescence; Radiation hardness; Spatial correlation; X-ray storage phosphors

Year:  2014        PMID: 24778460      PMCID: PMC4000036          DOI: 10.1016/j.nimb.2013.08.067

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res B        ISSN: 0168-583X            Impact factor:   1.377


  7 in total

1.  Theoretical and empirical investigations of KCl : Eu2+ for nearly water-equivalent radiotherapy dosimetry.

Authors:  Yuanshui Zheng; Zhaohui Han; Joseph P Driewer; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  Evaluation of a computed radiography system for megavoltage photon beam dosimetry.

Authors:  Arthur J Olch
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  Spatial correlation and photostimulability of defect centers in the x-ray-storage phosphor BaFBr:Eu2+

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1991-11-01

4.  Trapped charge migration in BaFBr:Eu2+: The recuperation of photostimulated luminescence.

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1996-03-01

5.  Participation of Eu-aggregates in the photoluminescence, afterglow and thermoluminescence of UV-irradiated KCl:Eu at 20 K.

Authors:  S Alvarez-García; T M Piters
Journal:  J Phys Condens Matter       Date:  2004-12-10       Impact factor: 2.333

6.  Radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry.

Authors:  Joseph P Driewer; Haijian Chen; Andres Osvet; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

  7 in total
  2 in total

1.  The role of oxygen in the photostimulation luminescence process of europium doped potassium chloride.

Authors:  Zhiyan Xiao; Thomas R Mazur; Joseph P Driewer; H Harold Li
Journal:  Radiat Meas       Date:  2015-05-01       Impact factor: 1.898

2.  Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

Authors:  H Harold Li; Joseph P Driewer; Zhaohui Han; Daniel A Low; Deshan Yang; Zhiyan Xiao
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.