Development of a storage phosphor imaging system for proton pencil beam spot profile determination.

Jufri Setianegara1,2, Thomas R Mazur1, Yao Hao1, Deshan Yang1, H Harold Li3.   

Abstract

PURPOSE: Accurate two-dimensional (2D) profile measurements at submillimeter precision are necessary for proton beam commissioning and periodic quality assurance (QA) purposes and are currently performed at our institution with a commercial scintillation detector (Lynx PT) with limited means for independent checks. The purpose of this work was to create an independent dosimetry system consisting of an in-house optical scanner and a BaFBrI:Eu2+ storage phosphor dosimeter by: (a) determining the optimal settings for the optical scanner, (b) measuring 2D proton spot profiles with the storage phosphors, and (c) comparing them to similar measurements using a commercial scintillation detector.
METHODS: An in-house 2D laboratory optical scanner was constructed and spatially calibrated for accurate 2D photostimulated luminescence (PSL) dosimetry. Square 5 × 5 cm2 BaFBrI:Eu2+ dosimeter samples were uniformly irradiated with line scans performed to determine the physical and electronic scanner settings resulting in the highest signal-to-noise ratios (SNR) at a sub-millimeter spatial resolution. The resultant spatial resolution of the scanner was then quantitatively assessed by measuring (a) line pairs on a standard X-ray lead bar phantom and (b) modulation transfer functions. Following this, 2D proton spot profiles from a Mevion S250i Hyperscan proton unit were obtained at 1, 10, 20, 30, 40, and 50 monitor unit (MU) settings at maximum energy (E0  = 227.1 MeV) and compared to baseline profiles from a commercial scintillation detector, where 1 MU is calibrated to deliver 1 Gy absolute proton dose-to-water under reference conditions, that is, 41 × 41 proton spots uniformly spaced by 0.25 cm within a 10 × 10 cm2 square field size at maximum energy (227.1 MeV) in water at depth of 5 cm at isocenter. The dosimetric system's sensitivities to (a) ±1 mm positional shifts and (b) ±0.3 mm beam lateral spread changes were quantitatively evaluated through a Gaussian fitting of the crossline and inline plots of the respective artificially shifted beam profiles.
RESULTS: The physical scanner settings of (a) Δτ = 27 ms time interval between data samples, (b) vx  = 1.235 cm/s scanning speed, (c) 1% laser transmission (0.02 mW power) and (d) (Δx, Δy) = (0.33, 0.50 mm) pixel sizes with electronic settings of (a) 300 microseconds time constant, (b) normal dynamic reserve, (c) 24 dB/oct low pass filter slope, and (d) 160 Hz chopping frequency resulted in the highest SNR while maintaining sub-millimeter spatial resolution. The BaFBr0.85 I0.15 :Eu2+ storage phosphor dosimeters were linear from 1 to 50 MU and their profiles did not saturate up to 150 MU. The scanner was able to detect lateral displacements of ±1 mm in both the crossline and inline directions and ±0.3 mm beam spread changes that were artificially introduced by varying the incident proton energy. Specific to our proton unit, proton energy changes of ±1 MeV can also be detected indirectly via beam spread measurements.
CONCLUSION: Our combined dosimetric system including an in-house laboratory optical scanner and reusable BaFBr0.85 I0.15 :Eu2+ storage phosphors demonstrated a sufficient spatial resolution and dosimetric accuracy to support its use as an independent proton spot measurement dosimeter system. Its wide dynamic range allows for other versatile applications such as proton halo measurements.
© 2021 American Association of Physicists in Medicine.

Entities:  

Keywords:  high-resolution dosimetry; proton pencil beam scanning; proton therapy dosimetry; storage phosphor dosimetry

Mesh:

Substances:

Year:  2021        PMID: 34318488      PMCID: PMC9278562          DOI: 10.1002/mp.15139

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.506


  24 in total

1.  Robust commercial diffuse reflector for UV-VIS-NIR applications.

Authors:  John D Mason; Michael T Cone; Matthew Donelon; Jeffery C Wigle; Gary D Noojin; Edward S Fry
Journal:  Appl Opt       Date:  2015-09-01       Impact factor: 1.980

2.  Technical Note: Validation of halo modeling for proton pencil beam spot scanning using a quality assurance test pattern.

Authors:  Liyong Lin; Sheng Huang; Minglei Kang; Timothy D Solberg; James E McDonough; Christopher G Ainsley
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

3.  Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzles.

Authors:  Liyong Lin; Christopher G Ainsley; Timothy D Solberg; James E McDonough
Journal:  Phys Med Biol       Date:  2013-12-30       Impact factor: 3.609

4.  A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

Authors:  Liyong Lin; Christopher G Ainsley; Thierry Mertens; Olivier De Wilde; Patrick T Talla; James E McDonough
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

5.  The M. D. Anderson proton therapy system.

Authors:  Alfred Smith; Michael Gillin; Martin Bues; X Ronald Zhu; Kazumichi Suzuki; Radhe Mohan; Shiao Woo; Andrew Lee; Ritsko Komaki; James Cox; Kazuo Hiramoto; Hiroshi Akiyama; Takayuki Ishida; Toshie Sasaki; Koji Matsuda
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

6.  AAPM task group 224: Comprehensive proton therapy machine quality assurance.

Authors:  Bijan Arjomandy; Paige Taylor; Christopher Ainsley; Sairos Safai; Narayan Sahoo; Mark Pankuch; Jonathan B Farr; Sung Yong Park; Eric Klein; Jacob Flanz; Ellen D Yorke; David Followill; Yuki Kase
Journal:  Med Phys       Date:  2019-06-14       Impact factor: 4.071

7.  Characterization of a commercial scintillation detector for 2-D dosimetry in scanned proton and carbon ion beams.

Authors:  S Russo; A Mirandola; S Molinelli; E Mastella; A Vai; G Magro; A Mairani; D Boi; M Donetti; M Ciocca
Journal:  Phys Med       Date:  2017-01-22       Impact factor: 2.685

8.  Commissioning and beam characterization of the first gantry-mounted accelerator pencil beam scanning proton system.

Authors:  M Kang; D Pang
Journal:  Med Phys       Date:  2020-07-06       Impact factor: 4.071

9.  Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements.

Authors:  H Harold Li; Zhiyan Xiao; Rachael Hansel; Nels Knutson; Deshan Yang
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

Review 10.  Secondary neutrons in clinical proton radiotherapy: a charged issue.

Authors:  David J Brenner; Eric J Hall
Journal:  Radiother Oncol       Date:  2008-01-14       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.