Literature DB >> 20966312

A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction.

Jonathon Leipsic1, Giang Nguyen, Jaqueline Brown, Don Sin, John R Mayo.   

Abstract

OBJECTIVE: The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. SUBJECTS AND METHODS: Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose.
RESULTS: Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p < 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p < 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p < 0.0001; Cronbach α, 0.85, p < 0.0001).
CONCLUSION: In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.

Entities:  

Mesh:

Year:  2010        PMID: 20966312     DOI: 10.2214/AJR.09.4050

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  70 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography.

Authors:  Jiro Sato; Masaaki Akahane; Sachiko Inano; Mariko Terasaki; Hiroyuki Akai; Masaki Katsura; Izuru Matsuda; Akira Kunimatsu; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-17       Impact factor: 2.374

Review 4.  Low-dose cardiovascular computed tomography: where are the limits?

Authors:  Paul Schoenhagen; Carla M Thompson; Sandra S Halliburton
Journal:  Curr Cardiol Rep       Date:  2012-02       Impact factor: 2.931

5.  Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT.

Authors:  Daisuke Utsunomiya; Wm Guy Weigold; Gaby Weissman; Allen J Taylor
Journal:  Eur Radiol       Date:  2011-12-27       Impact factor: 5.315

6.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

7.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

8.  The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

Authors:  Heejin Kwon; Jinhan Cho; Jongyeong Oh; Dongwon Kim; Junghyun Cho; Sanghyun Kim; Sangyun Lee; Jihyun Lee
Journal:  Br J Radiol       Date:  2015-08-03       Impact factor: 3.039

9.  Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients.

Authors:  L-P Qi; Y Li; L Tang; Y-L Li; X-T Li; Y Cui; Y-S Sun; X-P Zhang
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

10.  Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance.

Authors:  I Corcuera-Solano; A H Doshi; A Noor; L N Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-20       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.