Literature DB >> 20360635

Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

Brian E Nett1, Robert Brauweiler, Willi Kalender, Howard Rowley, Guang-Hong Chen.   

Abstract

Micro-CT scanning has become an accepted standard for anatomical imaging in small animal disease and genome mutation models. Concurrently, perfusion imaging via tracking contrast dynamics after injection of an iodinated contrast agent is a well-established tool for clinical CT scanners. However, perfusion imaging is not yet commercially available on the micro-CT platform due to limitations in both radiation dose and temporal resolution. Recent hardware developments in micro-CT scanners enable continuous imaging of a given volume through the use of a slip-ring gantry. Now that dynamic CT imaging is feasible, data may be acquired to measure tissue perfusion using a micro-CT scanner (CT Imaging, Erlangen, Germany). However, rapid imaging using micro-CT scanners leads to high image noise in individual time frames. Using the standard filtered backprojection (FBP) image reconstruction, images are prohibitively noisy for calculation of voxel-by-voxel perfusion maps. In this study, we apply prior image constrained compressed sensing (PICCS) to reconstruct images with significantly lower noise variance. In perfusion phantom experiments performed on a micro-CT scanner, the PICCS reconstruction enabled a reduction to 1/16 of the noise variance of standard FBP reconstruction, without compromising the spatial or temporal resolution. This enables a significant increase in dose efficiency, and thus, significantly less exposure time is needed to acquire images amenable to perfusion processing. This reduction in required irradiation time enables voxel-by-voxel perfusion maps to be generated on micro-CT scanners. Sample perfusion maps using a deconvolution-based perfusion analysis are included to demonstrate the improvement in image quality using the PICCS algorithm.

Entities:  

Mesh:

Year:  2010        PMID: 20360635      PMCID: PMC2931815          DOI: 10.1088/0031-9155/55/8/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  53 in total

1.  Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone.

Authors:  Michael J Thali; Ulrike Taubenreuther; Marek Karolczak; Marcel Braun; Walter Brueschweiler; Willi A Kalender; Richard Dirnhofer
Journal:  J Forensic Sci       Date:  2003-11       Impact factor: 1.832

2.  CT perfusion of the liver during selective hepatic arteriography: pure arterial blood perfusion of liver tumor and parenchyma.

Authors:  Atsushi Komemushi; Noboru Tanigawa; Hiroyuki Kojima; Shuji Kariya; Satoshi Sawada
Journal:  Radiat Med       Date:  2003 Nov-Dec

3.  A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source.

Authors:  G Cao; Y Z Lee; R Peng; Z Liu; R Rajaram; X Calderon-Colon; L An; P Wang; T Phan; S Sultana; D S Lalush; J P Lu; O Zhou
Journal:  Phys Med Biol       Date:  2009-03-25       Impact factor: 3.609

4.  CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke.

Authors:  James D Eastwood; Michael H Lev; Tarek Azhari; Ting-Yim Lee; Daniel P Barboriak; David M Delong; Clemens Fitzek; Michael Herzau; Max Wintermark; Reto Meuli; David Brazier; James M Provenzale
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

5.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

6.  [CT perfusion imaging in acute ischemic cerebral infarct: comparison of cerebral perfusion maps and conventional CT findings].

Authors:  M König; R Banach-Planchamp; M Kraus; E Klotz; A Falk; W Gehlen; L Heuser
Journal:  Rofo       Date:  2000-03

7.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations.

Authors:  C S Patlak; R G Blasberg
Journal:  J Cereb Blood Flow Metab       Date:  1985-12       Impact factor: 6.200

8.  Assessing tumor perfusion and treatment response in rectal cancer with multisection CT: initial observations.

Authors:  Dushyant V Sahani; Sanjeeva P Kalva; Leena M Hamberg; Peter F Hahn; Christopher G Willett; Sanjay Saini; Peter R Mueller; Ting-Yim Lee
Journal:  Radiology       Date:  2005-03       Impact factor: 11.105

9.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

10.  Pharmacokinetics, micro-SPECT/CT imaging and therapeutic efficacy of (188)Re-DXR-liposome in C26 colon carcinoma ascites mice model.

Authors:  Liang-Cheng Chen; Chih-Hsien Chang; Chia-Yu Yu; Ya-Jen Chang; Yu-Hsien Wu; Wan-Chi Lee; Chung-Hsin Yeh; Te-Wei Lee; Gann Ting
Journal:  Nucl Med Biol       Date:  2008-11       Impact factor: 2.408

View more
  16 in total

1.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

2.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.

Authors:  J C Ramirez-Giraldo; J Trzasko; S Leng; L Yu; A Manduca; C H McCollough
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

5.  Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging.

Authors:  Pascal Theriault Lauzier; Jie Tang; Michael A Speidel; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

6.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

7.  Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies.

Authors:  Bin Li; Qingwen Lyu; Jianhua Ma; Jing Wang
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

8.  4D micro-CT for cardiac and perfusion applications with view under sampling.

Authors:  Cristian T Badea; Samuel M Johnston; Yi Qi; G Allan Johnson
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

9.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

10.  C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.

Authors:  K Royalty; M Manhart; K Pulfer; Y Deuerling-Zheng; C Strother; A Fieselmann; D Consigny
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-23       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.