Literature DB >> 28981411

Z-Index Parameterization for Volumetric CT Image Reconstruction via 3-D Dictionary Learning.

Ti Bai, Hao Yan, Xun Jia, Steve Jiang, Ge Wang, Xuanqin Mou.   

Abstract

Despite the rapid developments of X-ray cone-beam CT (CBCT), image noise still remains a major issue for the low dose CBCT. To suppress the noise effectively while retain the structures well for low dose CBCT image, in this paper, a sparse constraint based on the 3-D dictionary is incorporated into a regularized iterative reconstruction framework, defining the 3-D dictionary learning (3-DDL) method. In addition, by analyzing the sparsity level curve associated with different regularization parameters, a new adaptive parameter selection strategy is proposed to facilitate our 3-DDL method. To justify the proposed method, we first analyze the distributions of the representation coefficients associated with the 3-D dictionary and the conventional 2-D dictionary to compare their efficiencies in representing volumetric images. Then, multiple real data experiments are conducted for performance validation. Based on these results, we found: 1) the 3-D dictionary-based sparse coefficients have three orders narrower Laplacian distribution compared with the 2-D dictionary, suggesting the higher representation efficiencies of the 3-D dictionary; 2) the sparsity level curve demonstrates a clear Z-shape, and hence referred to as Z-curve, in this paper; 3) the parameter associated with the maximum curvature point of the Z-curve suggests a nice parameter choice, which could be adaptively located with the proposed Z-index parameterization (ZIP) method; 4) the proposed 3-DDL algorithm equipped with the ZIP method could deliver reconstructions with the lowest root mean squared errors and the highest structural similarity index compared with the competing methods; 5) similar noise performance as the regular dose FDK reconstruction regarding the standard deviation metric could be achieved with the proposed method using (1/2)/(1/4)/(1/8) dose level projections. The contrast-noise ratio is improved by ~2.5/3.5 times with respect to two different cases under the (1/8) dose level compared with the low dose FDK reconstruction. The proposed method is expected to reduce the radiation dose by a factor of 8 for CBCT, considering the voted strongly discriminated low contrast tissues.

Entities:  

Mesh:

Year:  2017        PMID: 28981411      PMCID: PMC5732496          DOI: 10.1109/TMI.2017.2759819

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  22 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

Review 2.  Dental cone beam CT: A review.

Authors:  Timo Kiljunen; Touko Kaasalainen; Anni Suomalainen; Mika Kortesniemi
Journal:  Phys Med       Date:  2015-10-23       Impact factor: 2.685

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

4.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

5.  Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques.

Authors:  Lei Zhu; Lei Xing
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

6.  Emergence of simple-cell receptive field properties by learning a sparse code for natural images.

Authors:  B A Olshausen; D J Field
Journal:  Nature       Date:  1996-06-13       Impact factor: 49.962

7.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

8.  Low-dose X-ray CT reconstruction via dictionary learning.

Authors:  Qiong Xu; Hengyong Yu; Xuanqin Mou; Lei Zhang; Jiang Hsieh; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2012-04-20       Impact factor: 10.048

9.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

10.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

View more
  7 in total

1.  Dictionary learning sparse-sampling reconstruction method for in-vivo 3D photoacoustic computed tomography.

Authors:  Fangyan Liu; Xiaojing Gong; Lihong V Wang; Jingjing Guan; Liang Song; Jing Meng
Journal:  Biomed Opt Express       Date:  2019-03-05       Impact factor: 3.732

2.  Constructing a tissue-specific texture prior by machine learning from previous full-dose scan for Bayesian reconstruction of current ultralow-dose CT images.

Authors:  Yongfeng Gao; Jiaxing Tan; Yongyi Shi; Siming Lu; Amit Gupta; Haifang Li; Zhengrong Liang
Journal:  J Med Imaging (Bellingham)       Date:  2020-02-25

3.  Machine learned texture prior from full-dose CT database via multi-modality feature selection for Bayesian reconstruction of low-dose CT.

Authors:  Yongfeng Gao; Jiaxing Tan; Yongyi Shi; Hao Zhang; Siming Lu; Amit Gupta; Haifang Li; Michael Reiter; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2021-12-30       Impact factor: 11.037

4.  Spectral CT Reconstruction via Low-Rank Representation and Region-Specific Texture Preserving Markov Random Field Regularization.

Authors:  Yongyi Shi; Yongfeng Gao; Yanbo Zhang; Junqi Sun; Xuanqin Mou; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2020-03-26       Impact factor: 10.048

Review 5.  Applications of Deep Learning to Neuro-Imaging Techniques.

Authors:  Guangming Zhu; Bin Jiang; Liz Tong; Yuan Xie; Greg Zaharchuk; Max Wintermark
Journal:  Front Neurol       Date:  2019-08-14       Impact factor: 4.003

6.  Low-dose Cone-Beam Computed Tomography Reconstruction through a fast Three-Dimensional Compressed Sensing Method Based on the Three-Dimensional Pseudo-polar Fourier Transform.

Authors:  N Teyfouri; Hossein Rabbani; I Jabbari
Journal:  J Med Signals Sens       Date:  2021-12-28

7.  Dictionary learning compressed sensing reconstruction: pilot validation of accelerated echo planar J-resolved spectroscopic imaging in prostate cancer.

Authors:  Ajin Joy; Rajakumar Nagarajan; Andres Saucedo; Zohaib Iqbal; Manoj K Sarma; Neil Wilson; Ely Felker; Robert E Reiter; Steven S Raman; M Albert Thomas
Journal:  MAGMA       Date:  2022-07-23       Impact factor: 2.533

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.