Literature DB >> 25979068

Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Adam S Wang1, J Webster Stayman1, Yoshito Otake1, Sebastian Vogt2, Gerhard Kleinszig2, Jeffrey H Siewerdsen1.   

Abstract

PURPOSE: To accelerate model-based iterative reconstruction (IR) methods for C-arm cone-beam CT (CBCT), thereby combining the benefits of improved image quality and/or reduced radiation dose with reconstruction times on the order of minutes rather than hours.
METHODS: The ordered-subsets, separable quadratic surrogates (OS-SQS) algorithm for solving the penalized-likelihood (PL) objective was modified to include Nesterov's method, which utilizes "momentum" from image updates of previous iterations to better inform the current iteration and provide significantly faster convergence. Reconstruction performance of an anthropomorphic head phantom was assessed on a benchtop CBCT system, followed by CBCT on a mobile C-arm, which provided typical levels of incomplete data, including lateral truncation. Additionally, a cadaveric torso that presented realistic soft-tissue and bony anatomy was imaged on the C-arm, and different projectors were assessed for reconstruction speed.
RESULTS: Nesterov's method provided equivalent image quality to OS-SQS while reducing the reconstruction time by an order of magnitude (10.0 ×) by reducing the number of iterations required for convergence. The faster projectors were shown to produce similar levels of convergence as more accurate projectors and reduced the reconstruction time by another 5.3 ×. Despite the slower convergence of IR with truncated C-arm CBCT, comparison of PL reconstruction methods implemented on graphics processing units showed that reconstruction time was reduced from 106 min for the conventional OS-SQS method to as little as 2.0 min with Nesterov's method for a volumetric reconstruction of the head. In body imaging, reconstruction of the larger cadaveric torso was reduced from 159 min down to 3.3 min with Nesterov's method.
CONCLUSIONS: The acceleration achieved through Nesterov's method combined with ordered subsets reduced IR times down to a few minutes. This improved compatibility with clinical workflow better enables broader adoption of IR in CBCT-guided procedures, with corresponding benefits in overcoming conventional limits of image quality at lower dose.

Mesh:

Year:  2015        PMID: 25979068      PMCID: PMC4425726          DOI: 10.1118/1.4914378

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  45 in total

1.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

Authors:  G L Zeng; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

Review 2.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

3.  Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction.

Authors:  J A Fessler; E P Ficaro; N H Clinthorne; K Lange
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

4.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

5.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach.

Authors:  Frédéric A Miéville; François Gudinchet; Francis Brunelle; François O Bochud; Francis R Verdun
Journal:  Phys Med       Date:  2012-01-02       Impact factor: 2.685

6.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

7.  Prism representation: a 3D ray-tracing algorithm for radiotherapy applications.

Authors:  R L Siddon
Journal:  Phys Med Biol       Date:  1985-08       Impact factor: 3.609

8.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

9.  Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography.

Authors:  C Kamphuis; F J Beekman; P P van Rijk; M A Viergever
Journal:  Eur J Nucl Med       Date:  1998-01

10.  Accelerating ordered subsets image reconstruction for X-ray CT using spatially nonuniform optimization transfer.

Authors:  Donghwan Kim; Debashish Pal; Jean-Baptiste Thibault; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-06-07       Impact factor: 10.048

View more
  15 in total

Review 1.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

2.  Convergence criterion for MBIR based on the local noise-power spectrum: Theory and implementation in a framework for accelerated 3D image reconstruction with a morphological pyramid.

Authors:  A Sisniega; J W Stayman; S Capostagno; C R Weiss; T Ehtiati; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28

3.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

4.  An Investigation of Low-Dose 3D Scout Scans for Computed Tomography.

Authors:  Juliana Gomes; Grace J Gang; Aswin Mathews; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

5.  Hybrid spectral CT reconstruction.

Authors:  Darin P Clark; Cristian T Badea
Journal:  PLoS One       Date:  2017-07-06       Impact factor: 3.240

6.  Comparison Between Pre-Log and Post-Log Statistical Models in Ultra-Low-Dose CT Reconstruction.

Authors:  Adam M Alessio; Paul E Kinahan; Ken Sauer; Mannudeep K Kalra; Bruno De Man
Journal:  IEEE Trans Med Imaging       Date:  2016-11-09       Impact factor: 10.048

7.  Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.

Authors:  P Wu; A Sisniega; J W Stayman; W Zbijewski; D Foos; X Wang; N Khanna; N Aygun; R D Stevens; J H Siewerdsen
Journal:  Med Phys       Date:  2020-04-03       Impact factor: 4.071

8.  Numerical algorithms for scatter-to-attenuation reconstruction in PET: empirical comparison of convergence, acceleration, and the effect of subsets.

Authors:  Yannick Berker; Joel S Karp; Volkmar Schulz
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-06-08

9.  C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT.

Authors:  P Wu; N Sheth; A Sisniega; A Uneri; R Han; R Vijayan; P Vagdargi; B Kreher; H Kunze; G Kleinszig; S Vogt; S F Lo; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2020-08-19       Impact factor: 4.174

10.  Prior-image-based CT reconstruction using attenuation-mismatched priors.

Authors:  Hao Zhang; Dante Capaldi; Dong Zeng; Jianhua Ma; Lei Xing
Journal:  Phys Med Biol       Date:  2021-03-17       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.