Literature DB >> 20962368

Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Junguo Bian1, Jeffrey H Siewerdsen, Xiao Han, Emil Y Sidky, Jerry L Prince, Charles A Pelizzari, Xiaochuan Pan.   

Abstract

Flat-panel-detector x-ray cone-beam computed tomography (CBCT) is used in a rapidly increasing host of imaging applications, including image-guided surgery and radiotherapy. The purpose of the work is to investigate and evaluate image reconstruction from data collected at projection views significantly fewer than what is used in current CBCT imaging. Specifically, we carried out imaging experiments using a bench-top CBCT system that was designed to mimic imaging conditions in image-guided surgery and radiotherapy; we applied an image reconstruction algorithm based on constrained total-variation (TV)-minimization to data acquired with sparsely sampled view-angles and conducted extensive evaluation of algorithm performance. Results of the evaluation studies demonstrate that, depending upon scanning conditions and imaging tasks, algorithms based on constrained TV-minimization can reconstruct images of potential utility from a small fraction of the data used in typical, current CBCT applications. A practical implication of the study is that the optimization of algorithm design and implementation can be exploited for considerably reducing imaging effort and radiation dose in CBCT.

Entities:  

Mesh:

Year:  2010        PMID: 20962368      PMCID: PMC3597413          DOI: 10.1088/0031-9155/55/22/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

2.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.

Authors:  Marc Kachelriess; Michael Knaup; Olivier Bockenbach
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

5.  Aliasing: a source of streaks in computed tomograms.

Authors:  R D Brooks; G H Glover; A J Talbert; R L Eisner; F A DiBianca
Journal:  J Comput Assist Tomogr       Date:  1979-08       Impact factor: 1.826

6.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography.

Authors:  Emil Y Sidky; Mark A Anastasio; Xiaochuan Pan
Journal:  Opt Express       Date:  2010-05-10       Impact factor: 3.894

9.  Human observer detection experiments with mammograms and power-law noise.

Authors:  A E Burgess; F L Jacobson; P F Judy
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  90 in total

1.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle-Pock algorithm.

Authors:  Emil Y Sidky; Jakob H Jørgensen; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-04-27       Impact factor: 3.609

4.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

5.  Image reconstruction from sparse data in synchrotron-radiation-based microtomography.

Authors:  D Xia; X Xiao; J Bian; X Han; E Y Sidky; F De Carlo; X Pan
Journal:  Rev Sci Instrum       Date:  2011-04       Impact factor: 1.523

6.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Authors:  S Schafer; S Nithiananthan; D J Mirota; A Uneri; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; A J Khanna; J H Siewerdsena
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

8.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

9.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

10.  Iterative total-variation reconstruction versus weighted filtered-backprojection reconstruction with edge-preserving filtering.

Authors:  Gengsheng L Zeng; Ya Li; Alex Zamyatin
Journal:  Phys Med Biol       Date:  2013-04-26       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.