Literature DB >> 24370154

Whole-body CT angiography with low tube voltage and low-concentration contrast material to reduce radiation dose and iodine load.

Masayuki Kanematsu1, Satoshi Goshima, Toshiharu Miyoshi, Hiroshi Kondo, Haruo Watanabe, Yoshifumi Noda, Kyongtae T Bae.   

Abstract

OBJECTIVE: The purpose of this study was to prospectively evaluate the contrast enhancement, vascular depiction, image quality, and radiation dose of low-tube-voltage whole-body CT angiography (CTA) performed with low-concentration iodinated contrast material. SUBJECTS AND METHODS: Whole-body CTA was performed on 109 patients with a 64-MDCT scanner. Patients were randomized into three groups: CTA with 240-mg/mL contrast material at 80 kVp (240-80 group), 300-mg/mL at 80 kVp (300-80 group), and 370-mg/mL at 120 kVp (370-120 group). Signal-to-noise ratio (SNR), arterial depiction, image quality, and radiation dose were assessed. Figure of merit was computed to normalize signal-to-noise ratio, estimated effective dose, and iodine weight.
RESULTS: In the 240-80 group, the mean load of administered iodine was 21.6 g; for the 300-80 group, 26.8 g; and the 370-120 group, 34.0 g (p < 0.05). The ranges of mean vascular enhancement were 508-521 HU, 546-593 HU, and 435-442 HU (p < 0.05). Arterial depiction and image quality were comparable for the 240-80 and 370-120 groups and were greater for the 300-80 group than the other two groups in selected arteries (p < 0.05). Effective dose was higher (p < 0.05) in the 370-120 group (2.8-5.4 mSv) than in the others (2.3-4.3 mSv). The figure of merit in the 240-80 group was greater than (p < 0.05) or comparable to that in the 370-120 group.
CONCLUSION: Use of 240-mg/mL contrast material at 80 kVp seems appropriate for routine whole-body CTA and beneficial for reduction of iodine load and radiation dose, whereas use of 300-mg/mL contrast material may marginally improve delineation of selected small arteries.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24370154     DOI: 10.2214/AJR.13.10720

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

Authors:  Hee Jeong Shin; Song Soo Kim; Jae-Hwan Lee; Jae-Hyeong Park; Jin-Ok Jeong; Seon Ah Jin; Byung Seok Shin; Kyung-Sook Shin; Moonsang Ahn
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

2.  Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice.

Authors:  Wang Yuan; Ting-Ting Qu; Hui-Juan Wang; Mei-Yu Wang; Yuan Qu; Gang Niu; Jian Yang
Journal:  Curr Med Sci       Date:  2019-10-14

3.  Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium.

Authors:  Lu Zhao; Fengtan Li; Zewei Zhang; Zhang Zhang; Yingjian Jiang; Xinyu Wang; Jun Gu; Dong Li
Journal:  Eur Radiol       Date:  2018-04-13       Impact factor: 5.315

4.  Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT.

Authors:  Anna Winklehner; Sonja Gordic; Eliane Lauk; Thomas Frauenfelder; Sebastian Leschka; Hatem Alkadhi; Daniela B Husarik
Journal:  Eur Radiol       Date:  2015-02-19       Impact factor: 5.315

5.  Monitoring cerebral blood flow change through use of arterial spin labelling in acute ischaemic stroke patients after intra-arterial thrombectomy.

Authors:  Roh-Eul Yoo; Tae Jin Yun; Dong Hyun Yoo; Young Dae Cho; Hyun-Seung Kang; Byung-Woo Yoon; Keun-Hwa Jung; Koung Mi Kang; Seung Hong Choi; Ji-Hoon Kim; Chul-Ho Sohn
Journal:  Eur Radiol       Date:  2018-02-23       Impact factor: 5.315

6.  Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography.

Authors:  Jan-Erik Scholtz; Moritz Kaup; Johannes Kraft; Eva-Maria Nöske; Friedrich Scheerer; Boris Schulz; Iris Burck; Jens Wagenblast; J Matthias Kerl; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Neuroradiology       Date:  2015-03-26       Impact factor: 2.804

7.  Impact of low-kVp scan technique on oral contrast density at abdominopelvic CT.

Authors:  Douglas H Sheafor; Mark D Kovacs; Philip Burchett; Melissa M Picard; Brenton Davis; Andrew D Hardie
Journal:  Radiol Med       Date:  2018-08-06       Impact factor: 3.469

Review 8.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

9.  Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study.

Authors:  Michael M Lell; Ulrike Fleischmann; Hubertus Pietsch; Johannes G Korporaal; Ulrike Haberland; Andreas H Mahnken; Thomas G Flohr; Michael Uder; Gregor Jost
Journal:  PLoS One       Date:  2017-03-20       Impact factor: 3.240

10.  Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction.

Authors:  Yoshifumi Noda; Fumihiko Nakamura; Noriyuki Yasuda; Toshiharu Miyoshi; Nobuyuki Kawai; Hiroshi Kawada; Fuminori Hyodo; Masayuki Matsuo
Journal:  Br J Radiol       Date:  2021-02-22       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.