Literature DB >> 33617294

Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction.

Yoshifumi Noda1, Fumihiko Nakamura1, Noriyuki Yasuda1, Toshiharu Miyoshi1, Nobuyuki Kawai1, Hiroshi Kawada1, Fuminori Hyodo2, Masayuki Matsuo1.   

Abstract

OBJECTIVES: To assess the feasibility of whole-body dual-energy computed tomographic angiography (DECTA) at 40 keV with 50% reduced iodine dose protocol.
METHODS: Whole-body CTA was performed in 65 patients; 31 of these patients underwent 120 kVp single-energy computed tomographic angiography (SECTA) with standard iodine dose (600 mgI/kg) and 34 with 40 keV DECTA with 50% reduced iodine dose (300 mgI/kg). SECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (SECTA group), and DECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (DECTA-40% group) and 80% (DECTA-80% group). CT numbers of the thoracic and abdominal aorta, iliac artery, background noise, signal-to-noise ratio (SNR), and arterial depiction were compared among the three groups. The CT dose index volumes (CTDIvol) for the thorax, abdomen, and pelvis were compared between SECTA and DECTA protocols.
RESULTS: The vascular CT numbers and background noise were found to be significantly higher in DECTA groups than in the SECTA group (p < 0.001). SNR was significantly higher in the order corresponding to DECTA-80%, SECTA, and DECTA-40% (p < 0.001). The arterial depiction was comparable in almost all arteries; however, intrapelvic arterial depiction was significantly worse in DECTA groups than in the SECTA group (p < 0.0001-0.017). Unlike the pelvic region (p = 0.055), CTDIvol for the thorax (p < 0.0001) and abdomen (p = 0.0031) were significantly higher in the DECTA protocol than in the SECTA protocol.
CONCLUSION: DECTA at 40 keV with 50% reduced iodine dose provided higher vascular CT numbers and SNR than SECTA, and almost comparable arterial depiction, but had a degraded intrapelvic arterial depiction and required a larger radiation dose. ADVANCES IN KNOWLEDGE: DECTA enables 50% reduction of iodine dose while maintaining image quality, arterial depiction in almost all arteries, vascular CT numbers, and SNR; however, it does not allow clear visualization of intrapelvic arteries, requiring a slightly larger radiation dose compared with SECTA with standard iodine dose.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33617294      PMCID: PMC8506171          DOI: 10.1259/bjr.20201276

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Complications of endovascular repair for thoracic and abdominal aortic aneurysm: an imaging spectrum.

Authors:  T Mita; T Arita; N Matsunaga; M Furukawa; N Zempo; K Esato; M Matsuzaki
Journal:  Radiographics       Date:  2000 Sep-Oct       Impact factor: 5.333

Review 2.  Multidetector computed tomography in transcatheter aortic valve implantation.

Authors:  Jonathon Leipsic; Ronen Gurvitch; Troy M Labounty; James K Min; David Wood; Mark Johnson; Amr M Ajlan; Namal Wijesinghe; John G Webb
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

3.  High incidence of renal failure in patients with aortic aneurysms.

Authors:  Shinji Hagiwara; Shigeki Saima; Kousuke Negishi; Ryo Takeda; Naoko Miyauchi; Yurika Akiyama; Satoshi Horikoshi; Yasuhiko Tomino
Journal:  Nephrol Dial Transplant       Date:  2007-02-03       Impact factor: 5.992

4.  Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study.

Authors:  Daniele Marin; Juan Carlos Ramirez-Giraldo; Sonia Gupta; Wanyi Fu; Sandra S Stinnett; Achille Mileto; Davide Bellini; Bhavik Patel; Ehsan Samei; Rendon C Nelson
Journal:  AJR Am J Roentgenol       Date:  2016-04-08       Impact factor: 3.959

5.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Authors:  Stephan Achenbach; Victoria Delgado; Jörg Hausleiter; Paul Schoenhagen; James K Min; Jonathon A Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-11-14

6.  Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media.

Authors:  Katharine L Grant; Thomas G Flohr; Bernhard Krauss; Martin Sedlmair; Christoph Thomas; Bernhard Schmidt
Journal:  Invest Radiol       Date:  2014-09       Impact factor: 6.016

7.  Optimal window settings in single-source dual-energy computed tomography of the abdomen.

Authors:  Yoshifumi Noda; Satoshi Goshima; Kazuto Kozaka; Norihide Yoneda; Nozomi Mizuno; Akiko Kato; Keita Fujimoto; Yusuke Tsuji; Toshiharu Miyoshi; Hiroshi Kawada; Nobuyuki Kawai; Yukichi Tanahashi; Masayuki Matsuo
Journal:  Eur J Radiol       Date:  2018-10-23       Impact factor: 3.528

Review 8.  Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair.

Authors:  S William Stavropoulos; Sridhar R Charagundla
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

9.  Image Quality and Lesion Detection on Deep Learning Reconstruction and Iterative Reconstruction of Submillisievert Chest and Abdominal CT.

Authors:  Ramandeep Singh; Subba R Digumarthy; Victorine V Muse; Avinash R Kambadakone; Michael A Blake; Azadeh Tabari; Yiemeng Hoi; Naruomi Akino; Erin Angel; Rachna Madan; Mannudeep K Kalra
Journal:  AJR Am J Roentgenol       Date:  2020-01-22       Impact factor: 3.959

10.  Whole-body CT angiography with low tube voltage and low-concentration contrast material to reduce radiation dose and iodine load.

Authors:  Masayuki Kanematsu; Satoshi Goshima; Toshiharu Miyoshi; Hiroshi Kondo; Haruo Watanabe; Yoshifumi Noda; Kyongtae T Bae
Journal:  AJR Am J Roentgenol       Date:  2014-01       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.