Literature DB >> 31612403

Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice.

Wang Yuan1, Ting-Ting Qu1, Hui-Juan Wang2, Mei-Yu Wang1, Yuan Qu1, Gang Niu1, Jian Yang3.   

Abstract

To explore the feasibility and superiority of iodine delivery rate (IDR) and tube voltage determined by patients' body mass index (BMI) in coronary CT angiography (CCTA), a total of 1567 patients undertaking CCTA during Feb. and Dec. 2016 were enrolled and divided into two groups. In the control group, the IDR and tube voltage were fixed, while in the experimental group, the IDR and tube voltage were determined by patients' BMI. The volume of iodinated contrast media (ICM), extravasation rate, extravasation volume, extravasation recovery interval, incidence rate of adverse reactions, effective dose (ED) and image quality of the two groups were compared. The experiments demonstrated that the ICM volume, extravasation rate, extravasation volume, extravasation recovery interval, incidence of adverse reactions and ED were lower or shorter in the experimental group than in the control group, and the differences were statistically significant (all P<0.05). However, there were no significant differences in the mean CT value, image noise, signal to noise ratio and contrast to noise ratio between the two groups (all P<0.05), which were consistent with the diagnosticians' subjective evaluation outcomes. Our findings suggested that in CCTA, it is feasible to determine the IDR and tube voltage based on patients' BMI; low tube voltage and IDR are superior to the fixed tube voltage and IDR and are worthy of clinical promotion.

Entities:  

Keywords:  ICM extravasation; adverse reactions; iodinated contrast media; iodine delivery rate; tube voltage

Mesh:

Substances:

Year:  2019        PMID: 31612403     DOI: 10.1007/s11596-019-2112-5

Source DB:  PubMed          Journal:  Curr Med Sci        ISSN: 2523-899X


  20 in total

1.  Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method.

Authors:  Kyongtae T Bae; Huy Q Tran; Jay P Heiken
Journal:  Radiology       Date:  2004-06       Impact factor: 11.105

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study.

Authors:  Gudrun M Feuchtner; Daniel Jodocy; Andrea Klauser; Bernhard Haberfellner; Iman Aglan; Alexander Spoeck; Stefan Hiehs; Peter Soegner; Werner Jaschke
Journal:  Eur J Radiol       Date:  2009-08-09       Impact factor: 3.528

4.  Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.

Authors:  H Katayama; K Yamaguchi; T Kozuka; T Takashima; P Seez; K Matsuura
Journal:  Radiology       Date:  1990-06       Impact factor: 11.105

Review 5.  Adverse reactions to iodinated contrast media.

Authors:  Wendy Bottinor; Pritam Polkampally; Ion Jovin
Journal:  Int J Angiol       Date:  2013-09

6.  Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients.

Authors:  Madeleine Kok; Casper Mihl; Babs M F Hendriks; Sibel Altintas; Bas L J H Kietselaer; Joachim E Wildberger; Marco Das
Journal:  Eur J Radiol       Date:  2016-03-22       Impact factor: 3.528

7.  Hospital-acquired renal insufficiency.

Authors:  Kevin Nash; Abdul Hafeez; Susan Hou
Journal:  Am J Kidney Dis       Date:  2002-05       Impact factor: 8.860

8.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

9.  Whole-body CT angiography with low tube voltage and low-concentration contrast material to reduce radiation dose and iodine load.

Authors:  Masayuki Kanematsu; Satoshi Goshima; Toshiharu Miyoshi; Hiroshi Kondo; Haruo Watanabe; Yoshifumi Noda; Kyongtae T Bae
Journal:  AJR Am J Roentgenol       Date:  2014-01       Impact factor: 3.959

10.  Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate.

Authors:  Madeleine Kok; Casper Mihl; Anna Seehofnerová; Jakub Turek; Gregor Jost; Hubertus Pietsch; Ulrike Haberland; Joachim E Wildberger; Marco Das
Journal:  AJR Am J Roentgenol       Date:  2015-12       Impact factor: 3.959

View more
  1 in total

1.  Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA.

Authors:  Shang Ge; Jian-Yao Zhu; Han Liu; Yuan Chen; Zhao-Huan Zhu
Journal:  Contrast Media Mol Imaging       Date:  2022-07-16       Impact factor: 3.009

  1 in total