Literature DB >> 24364751

Reliability of anatomic structures as landmarks in three-dimensional cephalometric analysis using CBCT.

Pegah Naji1, Noura A Alsufyani, Manuel O Lagravère.   

Abstract

OBJECTIVE: To identify anatomic structures in three dimensions and examine their reliability to be used as landmarks in a three-dimensional coordinate cephalometric analysis, using cone-beam computerized tomography (CBCT).
MATERIALS AND METHODS: Thirty CBCT images were randomly selected for landmark location. Forty-two anatomic landmarks, which are not included in the traditional cephalometric landmarks, were chosen based on radiographic characteristics that make them pragmatic to mark in the CBCT image slices. The principal investigator marked the full set of landmarks on the software by navigating in the X, Y, and Z axes for every image three times, with each measurement trial being at least 1 week apart. One other investigator also located the landmarks once for each image for reliability purposes. Intraclass correlation coefficients (ICCs) were used to analyze the mean differences in landmark location in all axes.
RESULTS: Intra- and interexaminer reliability for x, y, and z coordinates for all landmarks had ICC greater than 0.95 with confidence interval of 0.88-0.99. Mean measurement differences found were <1.4 mm for all landmarks in all three coordinates. Mean measurement error differences obtained in the principal investigator's trials were primarily <0.5 mm.
CONCLUSION: The most reliable and reproducible landmarks tested for use in CBCT are mental foramina, infraorbital foramina, inferior hamulus, dens axis, foramina transversarium of atlas, medial and lateral condyles of the mandible, superior clinoid processes, and mid-clinoid.

Entities:  

Keywords:  Cone-beam computerized tomography; Orthodontics; Three-dimensional cephalometrics; X-rays

Mesh:

Year:  2013        PMID: 24364751      PMCID: PMC8641267          DOI: 10.2319/090413-652.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  29 in total

1.  A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

Authors:  Gwen R J Swennen; Filip Schutyser; Enno-Ludwig Barth; Pieter De Groeve; Albert De Mey
Journal:  J Craniofac Surg       Date:  2006-03       Impact factor: 1.046

2.  Comparative study between conventional and cone beam CT-synthesized half and total skull cephalograms.

Authors:  G S Liedke; E L Delamare; M B Vizzotto; H L D da Silveira; J R Prietsch; V Dutra; H E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

3.  Cone-beam computed tomography: accuracy of three-dimensional cephalometry analysis and influence of patient scanning position.

Authors:  Gianluigi Frongia; Maria Grazia Piancino; Pietro Bracco
Journal:  J Craniofac Surg       Date:  2012-07       Impact factor: 1.046

4.  Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images.

Authors:  Manuel O Lagravère; Corey Low; Carlos Flores-Mir; Raymund Chung; Jason P Carey; Giseon Heo; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-05       Impact factor: 2.650

5.  Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography.

Authors:  Allan G Farman; William C Scarfe
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-08       Impact factor: 2.650

6.  Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery.

Authors:  Lucia H S Cevidanes; L'Tanya J Bailey; Scott F Tucker; Martin A Styner; Andre Mol; Ceib L Phillips; William R Proffit; Timothy Turvey
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-01       Impact factor: 2.650

7.  Neurovascular anatomical variations in the anterior palate observed on CBCT images.

Authors:  Christiano de Oliveira-Santos; Izabel R F Rubira-Bullen; Solange A C Monteiro; Jorge E León; Reinhilde Jacobs
Journal:  Clin Oral Implants Res       Date:  2012-05-16       Impact factor: 5.977

8.  Precision of identifying cephalometric landmarks with cone beam computed tomography in vivo.

Authors:  Bassam Hassan; Peter Nijkamp; Hans Verheij; Jamshed Tairie; Christian Vink; Paul van der Stelt; Herman van Beek
Journal:  Eur J Orthod       Date:  2011-03-29       Impact factor: 3.075

9.  Prevalence and pattern of stylohyoid chain complex patterns detected by panoramic radiographs among Turkish population.

Authors:  Esin Alpoz; Gulcan Coskun Akar; Servet Celik; Figen Govsa; Gunnur Lomcali
Journal:  Surg Radiol Anat       Date:  2013-05-21       Impact factor: 1.246

10.  Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography.

Authors:  Ana Emilia F de Oliveira; Lucia Helena S Cevidanes; Ceib Phillips; Alexandre Motta; Brandon Burke; Donald Tyndall
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-08-20
View more
  15 in total

1.  A knowledge-based algorithm for automatic detection of cephalometric landmarks on CBCT images.

Authors:  Abhishek Gupta; Om Prakash Kharbanda; Viren Sardana; Rajiv Balachandran; Harish Kumar Sardana
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-07       Impact factor: 2.924

2.  Development and Validation of Novel Three-Dimensional Craniofacial Landmarks on Cone-Beam Computed Tomography Scans.

Authors:  Denise K Liberton; Payal Verma; Anthony Contratto; Janice S Lee
Journal:  J Craniofac Surg       Date:  2019-10       Impact factor: 1.046

3.  Reliability of three-dimensional anterior cranial base superimposition methods for assessment of overall hard tissue changes: A systematic review.

Authors:  Cecilia Ponce-Garcia; Manuel Lagravere-Vich; Lucia Helena Soares Cevidanes; Antonio Carlos de Olivera Ruellas; Jason Carey; Carlos Flores-Mir
Journal:  Angle Orthod       Date:  2017-11-30       Impact factor: 2.079

4.  Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography : A systematic review.

Authors:  Alycia Sam; Kris Currie; Heesoo Oh; Carlos Flores-Mir; Manuel Lagravére-Vich
Journal:  Angle Orthod       Date:  2018-11-13       Impact factor: 2.079

5.  A three-dimensional method to calculate mechanical advantage in mandibular function : Intra- and interexaminer reliability study.

Authors:  Alejandro Sánchez-Ayala; Alfonso Sánchez-Ayala; Rafaela Cristina Kolodzejezyk; Vanessa Migliorini Urban; Manuel Óscar Lagravère; Nara Hellen Campanha
Journal:  J Orofac Orthop       Date:  2022-03-07       Impact factor: 1.938

6.  A six-site method for the evaluation of periodontal bone loss in cone-beam CT images.

Authors:  Yu-Jiao Guo; Zhi-pu Ge; Ruo-han Ma; Jian-xia Hou; Gang Li
Journal:  Dentomaxillofac Radiol       Date:  2015-10-28       Impact factor: 2.419

Review 7.  3D superimposition of craniofacial imaging-The utility of multicentre collaborations.

Authors:  Marilia Yatabe; Juan Carlos Prieto; Martin Styner; Hongtu Zhu; Antonio Carlos Ruellas; Beatriz Paniagua; Francois Budin; Erika Benavides; Brandon Shoukri; Loic Michoud; Nina Ribera; Lucia Cevidanes
Journal:  Orthod Craniofac Res       Date:  2019-05       Impact factor: 1.826

8.  Modern 3D cephalometry in pediatric orthodontics-downsizing the FOV and development of a new 3D cephalometric analysis within a minimized large FOV for dose reduction.

Authors:  Pamela Kissel; James K Mah; Axel Bumann
Journal:  Clin Oral Investig       Date:  2021-01-25       Impact factor: 3.573

9.  Influence of maxillary advancement surgery on skeletal and soft-tissue changes in the nose - a retrospective cone-beam computed tomography study.

Authors:  Andreas F Hellak; Bernhard Kirsten; Michael Schauseil; Rolf Davids; Wolfgang M Kater; Heike M Korbmacher-Steiner
Journal:  Head Face Med       Date:  2015-07-09       Impact factor: 2.151

Review 10.  Reliability and reproducibility of three-dimensional cephalometric landmarks using CBCT: a systematic review.

Authors:  Cinthia de Oliveira Lisboa; Daniele Masterson; Andréa Fonseca Jardim da Motta; Alexandre Trindade Motta
Journal:  J Appl Oral Sci       Date:  2015 Mar-Apr       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.