| Literature DB >> 24136290 |
Bart M Koene1, Mohamed A Soliman Hamad, Wobbe Bouma, Massimo A Mariani, Kathinka C Peels, Jan-Melle van Dantzig, Albert H van Straten.
Abstract
BACKGROUND: In this study, we sought to determine the effect of the mean transprosthetic pressure gradient (TPG), measured at 6 weeks after aortic valve replacement (AVR) or AVR with coronary artery bypass grafting (CABG) on late all-cause mortality.Entities:
Mesh:
Year: 2013 PMID: 24136290 PMCID: PMC3904035 DOI: 10.1007/s00392-013-0629-3
Source DB: PubMed Journal: Clin Res Cardiol ISSN: 1861-0684 Impact factor: 5.460
Characteristics for each pressure gradient group (n = 2,264)
| Variable | Low gradient | Moderate gradient | High gradient |
|
|---|---|---|---|---|
| (<10 mmHg) | (10–19 mmHg) | (≥20 mmHg) | ||
| Age (years) | 70 ± 10 | 67 ± 11 | 65 ± 12 | <0.001 |
| Sex | ||||
| Female | 328 (37.4) | 448 (37.8) | 56 (27.5) | 0.015 |
| Endocarditis | 27 (3.1) | 54 (4.6) | 14 (6.9) | 0.035 |
| Preoperative LV function | ||||
| Severely impaired (EF < 30 %) | 39 (4.5) | 27 (2.3) | 4 (2.0) | 0.012 |
| Hypertension | 406 (46.3) | 549 (46.4) | 78 (38.2) | 0.085 |
| Diabetes mellitus | 151 (17.2) | 203 (17.1) | 33 (16.2) | 0.934 |
| Body weight (kg) | 77 ± 13 | 79 ± 14 | 81 ± 16 | <0.001 |
| Height (cm) | 170 ± 9 | 170 ± 9 | 171 ± 9 | 0.172 |
| Body surface area, BSA (m2) | 1.88 ± 0.19 | 1.91 ± 0.19 | 1.92 ± 0.21 | 0.002 |
| Body mass index, BMI (kg/m2) | 26.8 ± 4.0 | 27.4 ± 4.2 | 27.5 ± 4.7 | 0.006 |
| Peripheral vascular disease (PVD) | 108 (12.3) | 111 (9.4) | 20 (9.8) | 0.091 |
| Renal dysfunction | 46 (5.3) | 65 (5.5) | 11 (5.4) | 0.972 |
| Chronic obstructive pulmonary disease (COPD) | 144 (16.4) | 194 (16.4) | 41 (20.1) | 0.404 |
| Cerebrovascular accident (CVA) | 36 (4.1) | 64 (5.4) | 12 (5.9) | 0.305 |
| Previous cardiac surgery | 64 (7.3) | 85 (7.2) | 31 (15.2) | <0.001 |
| Additive EuroSCORE | 6.2 ± 2.5 | 5.9 ± 2.5 | 5.8 ± 2.5 | 0.052 |
| Logistic EuroSCORE | 7.93 ± 8.33 | 7.06 ± 7.06 | 7.18 ± 7.69 | 0.075 |
| Prosthetic valve diameter, mm | ||||
| Median | 23 | 23 | 23 | |
| Prosthetic valve type | ||||
| Mechanical | 367 (41.9) | 580 (52.3) | 120 (58.8) | <0.001 |
| Concomitant coronary artery bypass grafting | 424 (48.4) | 464 (39.2) | 66 (32.4) | <0.001 |
| Cardiopulmonary bypass time (min) | 95 ± 37 | 91 ± 36 | 93 ± 32 | 0.024 |
| Aortic cross-clamp time (min) | 70 ± 26 | 68 ± 25 | 68 ± 22 | 0.147 |
| Effective orifice area (EOA) (cm2) | 2.16 ± 0.48 | 2.06 ± 0.42 | 1.94 ± 0.40 | <0.001 |
| Indexed effective orifice area (EOAI) (cm2/m2) | 1.15 ± 0.24 | 1.08 ± 0.21 | 1.01 ± 0.21 | <0.001 |
| PPM (EOAI ≤0.85 cm2/m2) | 43 (4.9) | 145 (12.2) | 51 (25.0) | <0.001 |
| Severe PPM (EOAI <0.65 cm2/m2) | 2 (0.2) | 2 (0.2) | 3 (1.5) | 0.007 |
| Mean transprosthetic gradient, TPG (mmHg) | 6 ± 3 | 13 ± 3 | 28 ± 11 | <0.001 |
| Mean follow-up (years) | 5.1 ± 3.5 | 5.7 ± 3.5 | 5.5 ± 3.5 | <0.001 |
Data are presented as mean ± standard deviation or number (%)
EF ejection fraction, LV left ventricular, PPM prosthesis–patient mismatch
Prosthetic valve distribution (n = 2,264)
| Variable | Value |
|---|---|
| Prosthetic valve diameter (mm) | |
| Median | 23 mm |
| Prosthetic valve type | |
| Mechanical | 1,067 (47.1) |
| St. Jude Medical Standard | 577 (25.5) |
| ATS | 377 (16.7) |
| St. Jude Medical Regent | 77 (3.4) |
| St. Jude Medical HP | 36 (1.6) |
| Biological (stented) | 1,197 (52.9) |
| Carpentier–Edwards Magna | 142 (6.3) |
| Carpentier-Edwards Perimount | 412 (18.2) |
| Sorin Mitroflow | 291 (12.9) |
| Medtronic Mosaic | 98 (4.3) |
| St. Jude Trifecta | 87 (3.8) |
| St. Jude Medical Epic | 167 (7.4) |
Data are number of patients (%)
Fig. 1Long-term survival after transthoracic echocardiographic (TTE) evaluation of the mean transprosthetic pressure gradient (TPG) 6 weeks after surgery stratified per gradient group. Difference in survival between the groups was not significant (p = 0.258)
Univariate and multivariate Cox analysis of late (>6 weeks) mortality
| Variable | Univariate analysis | Multivariate analysis | ||
|---|---|---|---|---|
|
| HR (95 % CI) |
| HR (95 % CI) | |
| Age (years)a | <0.001 | 1.07 (1.06–1.08) | <0.001 | 1.06 (1.05–1.08) |
| Sex (female) | 0.804 | 1.03 (0.84–1.25) | ||
| Severely impaired LV function (EF < 30 %) | 0.040 | 1.57 (1.02–2.41) | 0.062 | 1.51 (0.98–2.34) |
| Hypertension | 0.003 | 1.33 (1.10–1.61) | 0.449 | 1.08 (0.89–1.31) |
| Diabetes mellitus | <0.001 | 1.81 (1.44–2.29) | 0.003 | 1.44 (1.13–1.83) |
| Endocarditis | 0.115 | 0.62 (0.34–1.12) | ||
| Gradient groupb | ||||
| 10–19 mmHg | 0.107 | 0.85 (0.69–1.04) | 0.781 | 0.97 (0.79–1.19) |
| ≥20 mmHg | 0.815 | 0.96 (0.69–1.34) | 0.496 | 1.13 (0.80–1.59) |
| Gradienta | 0.156 | 0.99 (0.98–1.00) | ||
| Body mass index, BMI (kg/m2) | 0.535 | 1.01 (0.98–1.03) | ||
| Peripheral vascular disease (PVD) | <0.001 | 2.37 (1.84–3.06) | <0.001 | 1.81 (1.40–2.35) |
| Renal dysfunction | <0.001 | 2.21 (1.53–3.18) | 0.007 | 1.66 (1.15–2.41) |
| Chronic obstructive pulmonary disease (COPD) | <0.001 | 1.70 (1.37–2.12) | <0.001 | 1.70 (1.37–2.13) |
| Cerebrovascular accident (CVA) | <0.001 | 2.09 (1.50–2.92) | 0.001 | 1.78 (1.27–2.49) |
| Mechanical prosthetic valvec | <0.001 | 0.45 (0.37–0.55) | 0.394 | 0.90 (0.70–1.15) |
| Concomitant coronary artery bypass grafting (CABG) | <0.001 | 1.56 (1.29–1.88) | 0.920 | 0.99 (0.79–1.24) |
| Cardiopulmonary bypass (CPB) time (min)a | <0.001 | 1.01 (1.00–1.01) | 0.011 | 1.00 (1.00–1.01) |
| Aortic cross-clamp time (min)a | <0.001 | 1.01 (1.00–1.01) | 0.495 | 1.00 (0.99–1.00) |
| Prosthesis–patient mismatch (PPM) (EOAI ≤0.85 cm2/m2) | 0.175 | 1.20 (0.92–1.56) | ||
| Severe PPM (EOAI <0.65 cm2/m2) | 0.423 | 1.77 (0.44–7.09) | ||
| Previous cardiac surgery | 0.151 | 1.29 (0.91–1.82) | ||
CI confidence interval, EF ejection fraction, HR hazard ratio, LV left ventricular
aEntered as a continuous variable
bCompared to low-gradient group
cCompared to biological valves