BACKGROUND: The prosthesis used for aortic valve replacement (AVR) can be too small in relation to body size, thus causing valve prosthesis-patient mismatch (PPM) and abnormally high transvalvular pressure gradients. This study examined if there is a relation between PPM and short-term mortality after operation. METHODS AND
RESULTS: The indexed valve effective orifice area (EOA) was estimated for each type and size of prosthesis being implanted in 1266 consecutive patients and used to define PPM as not clinically significant if >0.85 cm2/m2, as moderate if >0.65 cm2/m2 and <or=0.85 cm2/m2, and as severe if <or=0.65 cm2/m2; it was correlated with 30-day mortality and compared with other relevant variables. Moderate or severe PPM was present in 38% of patients. Thirty-day mortality was 4.6% (58/1266 patients) and the strongest independent predictors in multivariate analysis were left ventricular ejection fraction <40% (P=0.007), infectious endocarditis (P=0.002), emergent/salvage operation (P=0.002), cardiopulmonary bypass time >120 minutes (P=0.001), and PPM (P=0.003). Relative risk of mortality was increased 2.1-fold (95% confidence interval, 1.2 to 3.7) in patients with moderate PPM and 11.4-fold (4.4 to 29.5) in those with severe PPM. Moreover, risk of mortality for every category of PPM was higher in patients with a left ventricular ejection fraction <40% as compared with >or=40% (nonsignificant PPM, 2.7 versus 1.0; moderate PPM, 7.1 versus 1.8; severe PPM, 77.1 versus 11.3).
CONCLUSIONS: PPM is a strong and independent predictor of short-term mortality among patients undergoing AVR, and its impact is related both to its degree of severity and the status of left ventricular function. In contrast to other risk factors, moderate-severe PPM can be largely avoided with the use of a prospective strategy at the time of operation.

Entities:  

Mesh:

Year:  2003        PMID: 12912812     DOI: 10.1161/01.CIR.0000085167.67105.32

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  77 in total

Review 1.  A 44-year experience of prosthetic heart valve implantation at Niigata University Hospital.

Authors:  Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2012-04-24       Impact factor: 1.731

Review 2.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

3.  Aortic valve replacement with a 16-mm CarboMedics valve in adult patients.

Authors:  Takeru Shimomura; Tadahito Eda; Shuichi Suzuki; Ken Miyahara; Akio Matsuura; Katsuhiko Yoshida
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-06

4.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

Review 5.  Low-gradient aortic valve stenosis: value and limitations of dobutamine stress testing.

Authors:  J Bermejo; R Yotti
Journal:  Heart       Date:  2006-04-18       Impact factor: 5.994

6.  Patient-prosthesis mismatch after transapical aortic valve implantation.

Authors:  Marian Kukucka; Miralem Pasic; Stephan Dreysse; Semih Buz; Thorsten Drews; Alexander Mladenow; Helmut Habazettl; Hermann Kuppe; Axel Unbehaun; Roland Hetzer
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 7.  Natriuretic peptides in the management of aortic stenosis.

Authors:  Jutta Bergler-Klein
Journal:  Curr Cardiol Rep       Date:  2009-03       Impact factor: 2.931

Review 8.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

9.  Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation.

Authors:  Hatim Seoudy; Nathalie Güßefeld; Johanne Frank; Sandra Freitag-Wolf; Georg Lutter; Matthias Eden; Ashraf Yusuf Rangrez; Christian Kuhn; Norbert Frey; Derk Frank
Journal:  Clin Res Cardiol       Date:  2018-11-19       Impact factor: 5.460

Review 10.  Low-gradient aortic stenosis.

Authors:  Marie-Annick Clavel; Julien Magne; Philippe Pibarot
Journal:  Eur Heart J       Date:  2016-03-31       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.