Prosthesis-patient mismatch affects survival after aortic valve replacement.

V Rao1, W R Jamieson, J Ivanov, S Armstrong, T E David.   

Abstract

BACKGROUND: Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. METHODS AND
RESULTS: Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P:=0.03). Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P:=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P:=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality.
CONCLUSIONS: Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.

Entities:  

Mesh:

Year:  2000        PMID: 11082354     DOI: 10.1161/01.cir.102.suppl_3.iii-5

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  40 in total

1.  Aortic stenosis: An update.

Authors:  Sangeetha Nathaniel; Shreyas Saligram; Antony Leslie Innasimuthu
Journal:  World J Cardiol       Date:  2010-06-26

Review 2.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

3.  Patient-prosthesis mismatch after transapical aortic valve implantation.

Authors:  Marian Kukucka; Miralem Pasic; Stephan Dreysse; Semih Buz; Thorsten Drews; Alexander Mladenow; Helmut Habazettl; Hermann Kuppe; Axel Unbehaun; Roland Hetzer
Journal:  Ann Cardiothorac Surg       Date:  2012-07

4.  Long-term results after aortic root replacement using self-assembled valve composite grafts in patients with small aortic annulus.

Authors:  Paul P Urbanski; Witold Dinstak; Wilko Rents; Nicolas Heinz; Anno Diegeler
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-10-30

5.  10-year results of On-X bileaflet mechanical heart valve in the aortic position: low target INR regimen in Japanese.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Yosuke Miyamoto; Ryuta Tai; Toshikazu Sano; Yusuke Kinugasa; Hiroyuki Irie
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-04-19

6.  Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch.

Authors:  Abdulhameed Aziz; Jennifer S Lawton; Hersh S Maniar; Michael K Pasque; Ralph J Damiano; Marc R Moon
Journal:  Ann Thorac Surg       Date:  2010-10       Impact factor: 4.330

Review 7.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

8.  Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation.

Authors:  Hatim Seoudy; Nathalie Güßefeld; Johanne Frank; Sandra Freitag-Wolf; Georg Lutter; Matthias Eden; Ashraf Yusuf Rangrez; Christian Kuhn; Norbert Frey; Derk Frank
Journal:  Clin Res Cardiol       Date:  2018-11-19       Impact factor: 5.460

9.  Pulmonary hypertension in cardiac surgery.

Authors:  André Denault; Alain Deschamps; Jean-Claude Tardif; Jean Lambert; Louis Perrault
Journal:  Curr Cardiol Rev       Date:  2010-02

10.  Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Toshikazu Sano; Ryuta Tai; Naohiro Horio; Hiroyuki Irie
Journal:  J Artif Organs       Date:  2014-05-31       Impact factor: 1.731