Construction and Evaluation of a Prototype High Resolution, Silicon Photomultiplier-Based, Tandem Positron Emission Tomography System.

Alexander V Stolin1, Stan Majewski, Gangadhar Jaliparthi, Raymond R Raylman.   

Abstract

While the performance of most current commercially available PET scanners is sufficient for many standard clinical applications, some specific tasks likely require specialized imaging systems. The goal of this project is to explore the capabilities and limitations of a small, high-resolution prototype system for obtaining PET images. The scanner consists of a tandem of detectors. One is a small detector consisting of a 20 × 20 array of 0.7 × 0.7 × 3 mm3 (pitch 0.8 mm) LYSO elements. The scintillator array is coupled to an array of silicon photomultipliers. The second detector is a 96 × 72 array of 2 × 2 × 15 mm3 (pitch = 2.1 mm) LYSO elements coupled to PSPMTs. Separation between the two devices is 180 mm. The detectors are operated in coincidence with each other. Image reconstruction is performed using a limited angle, Maximum Likelihood Expectation Maximization (MLEM) algorithm. Evaluation of the device included measurements of spatial resolution and detection sensitivity as a function of distance. The transaxial radial and tangential spatial resolution of the system ranged from 0.6 mm to 0.9 mm FWHM; axial resolution ranged from 2.7 mm to 4.6 mm FWHM. Detection sensitivity ranged from 0.05 to 0.28%. Spatial resolution and field-of-view vary as a function of distance from the small detector. The tandem detector insert permitted differentiation of the smallest (1 mm diameter) rods in a mini-hot rod phantom. The results indicate that a tandem PET imaging scheme can be potentially employed in applications where high-resolution images over a small region are required.

Entities:  

Keywords:  High resolution; PET instrumentation; nuclear medicine imaging

Year:  2013        PMID: 24077362      PMCID: PMC3783350          DOI: 10.1109/tns.2013.2237788

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  7 in total

1.  NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner.

Authors:  Rameshwar Prasad; Osman Ratib; Habib Zaidi
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

2.  Physical and clinical performance of the mCT time-of-flight PET/CT scanner.

Authors:  B W Jakoby; Y Bercier; M Conti; M E Casey; B Bendriem; D W Townsend
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

3.  Virtual-pinhole PET.

Authors:  Yuan-Chuan Tai; Heyu Wu; Debashish Pal; Joseph A O'Sullivan
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements.

Authors:  Raymond R Raylman; Stan Majewski; Mark F Smith; James Proffitt; William Hammond; Amarnath Srinivasan; John McKisson; Vladimir Popov; Andrew Weisenberger; Clifford O Judy; Brian Kross; Srikanth Ramasubramanian; Larry E Banta; Paul E Kinahan; Kyle Champley
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

5.  Experimental assessment of resolution improvement of a zoom-in PET.

Authors:  Jinyi Qi; Yongfeng Yang; Jian Zhou; Yibao Wu; Simon R Cherry
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

6.  FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection.

Authors:  C D Ramos; Y E Erdi; M Gonen; E Riedel; H W Yeung; H A Macapinlac; R Chisin; S M Larson
Journal:  Eur J Nucl Med       Date:  2001-02

7.  Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems.

Authors:  Daniel B Keesing; Aswin Mathews; Sergey Komarov; Heyu Wu; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

  7 in total
  4 in total

1.  Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Emilie Roncali; Gregory S Mitchell; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

2.  Evaluation of a high resolution silicon PET insert module.

Authors:  Milan Grkovski; Karol Brzezinski; Vladimir Cindro; Neal H Clinthorne; Harris Kagan; Carlos Lacasta; Marko Mikuž; Carles Solaz; Andrej Studen; Peter Weilhammer; Dejan Žontar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-04-08       Impact factor: 1.455

3.  Feasibility study of a point-of-care positron emission tomography system with interactive imaging capability.

Authors:  Jianyong Jiang; Ke Li; Sergey Komarov; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Med Phys       Date:  2019-02-14       Impact factor: 4.071

4.  New prospects for PET in prostate cancer imaging: a physicist's viewpoint.

Authors:  Maurizio Conti
Journal:  EJNMMI Phys       Date:  2014-09-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.