Physical and clinical performance of the mCT time-of-flight PET/CT scanner.

B W Jakoby1, Y Bercier, M Conti, M E Casey, B Bendriem, D W Townsend.   

Abstract

Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.

Entities:  

Mesh:

Year:  2011        PMID: 21427485     DOI: 10.1088/0031-9155/56/8/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  155 in total

1.  Evaluation of Hamamatsu PET imaging modules for dedicated TOF-capable scanners.

Authors:  A Stolin; G Jaliparthi; R R Raylman; J Brefczynski-Lewis; S Majewski; J Qi; K Gong; S Dolinsky
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01-23

2.  A novel approach to assess the treatment response using Gaussian random field in PET.

Authors:  Mengdie Wang; Ning Guo; Guangshu Hu; Georges El Fakhri; Hui Zhang; Quanzheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

Review 3.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

4.  Evaluation of Parallel Level Sets and Bowsher's Method as Segmentation-Free Anatomical Priors for Time-of-Flight PET Reconstruction.

Authors:  Georg Schramm; Martin Holler; Ahmadreza Rezaei; Kathleen Vunckx; Florian Knoll; Kristian Bredies; Fernando Boada; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2018-02       Impact factor: 10.048

5.  PET Image Reconstruction Using Deep Image Prior.

Authors:  Kuang Gong; Ciprian Catana; Jinyi Qi; Quanzheng Li
Journal:  IEEE Trans Med Imaging       Date:  2018-12-19       Impact factor: 10.048

6.  Dual time point method for the quantification of irreversible tracer kinetics: A reference tissue approach applied to [18F]-FDOPA brain PET.

Authors:  I Lopes Alves; Sanne K Meles; Antoon Tm Willemsen; Rudi A Dierckx; Ana M Marques da Silva; Klaus L Leenders; Michel Koole
Journal:  J Cereb Blood Flow Metab       Date:  2016-12-19       Impact factor: 6.200

7.  Theoretical study of the benefit of long axial field-of-view PET on region of interest quantification.

Authors:  Xuezhu Zhang; Ramsey D Badawi; Simon R Cherry; Jinyi Qi
Journal:  Phys Med Biol       Date:  2018-06-27       Impact factor: 3.609

8.  DOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging.

Authors:  R I Wiener; S Surti; J S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

9.  Resolution Enhancement in PET Reconstruction Using Collimation.

Authors:  Scott D Metzler; Samuel Matej; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-02       Impact factor: 1.679

10.  The effect of time-of-flight and point spread function modeling on 82Rb myocardial perfusion imaging of obese patients.

Authors:  Paul K R Dasari; Judson P Jones; Michael E Casey; Yuanyuan Liang; Vasken Dilsizian; Mark F Smith
Journal:  J Nucl Cardiol       Date:  2018-06-15       Impact factor: 5.952