Literature DB >> 24027608

Automatic Tissue Classification for High-resolution Breast CT Images Based on Bilateral Filtering.

Xiaofeng Yang1, Ioannis Sechopoulos, Baowei Fei.   

Abstract

Breast tissue classification can provide quantitative measurements of breast composition, density and tissue distribution for diagnosis and identification of high-risk patients. In this study, we present an automatic classification method to classify high-resolution dedicated breast CT images. The breast is classified into skin, fat and glandular tissue. First, we use a multiscale bilateral filter to reduce noise and at the same time keep edges on the images. As skin and glandular tissue have similar CT values in breast CT images, we use morphologic operations to get the mask of the skin based on information of its position. Second, we use a modified fuzzy C-mean classification method twice, one for the skin and the other for the fatty and glandular tissue. We compared our classified results with manually segmentation results and used Dice overlap ratios to evaluate our classification method. We also tested our method using added noise in the images. The overlap ratios for glandular tissue were above 94. 7% for data from five patients. Evaluation results showed that our method is robust and accurate.

Entities:  

Keywords:  Breast CT; bias correction; breast cancer; breast tissue classification; fuzzy C-Mean classification; image classification; multiscale filter

Year:  2011        PMID: 24027608      PMCID: PMC3766982          DOI: 10.1117/12.877881

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  15 in total

1.  Dosimetric characterization of a dedicated breast computed tomography clinical prototype.

Authors:  Ioannis Sechopoulos; Steve Si Jia Feng; Carl J D'Orsi
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Retrospective correction of intensity inhomogeneities in MRI.

Authors:  C R Meyer; P H Bland; J Pipe
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

3.  New technique for real-time interface pressure analysis: getting more out of large image data sets.

Authors:  Kath Bogie; Xiaofeng Wang; Baowei Fei; Jiayang Sun
Journal:  J Rehabil Res Dev       Date:  2008

4.  Classification of breast computed tomography data.

Authors:  Thomas R Nelson; Laura I Cerviño; John M Boone; Karen K Lindfors
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

5.  The effect of skin thickness determined using breast CT on mammographic dosimetry.

Authors:  Shih-Ying Huang; John M Boone; Kai Yang; Alexander L C Kwan; Nathan J Packard
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

6.  Multiscale Fuzzy C-Means Image Classification for Multiple Weighted MR Images for the Assessment of Photodynamic Therapy in Mice.

Authors:  Hesheng Wang; Denise Feyes; John Mulvihill; Nancy Oleinick; Gregory Maclennan; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007-03-08

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  A modified fuzzy C-means classification method using a multiscale diffusion filtering scheme.

Authors:  Hesheng Wang; Baowei Fei
Journal:  Med Image Anal       Date:  2008-07-05       Impact factor: 8.545

9.  Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography.

Authors:  Patricia A Carney; Diana L Miglioretti; Bonnie C Yankaskas; Karla Kerlikowske; Robert Rosenberg; Carolyn M Rutter; Berta M Geller; Linn A Abraham; Steven H Taplin; Mark Dignan; Gary Cutter; Rachel Ballard-Barbash
Journal:  Ann Intern Med       Date:  2003-02-04       Impact factor: 25.391

10.  High-field magnetic resonance imaging of the response of human prostate cancer to Pc 4-based photodynamic therapy in an animal model.

Authors:  Baowei Fei; Hesheng Wang; Joseph D Meyers; Denise K Feyes; Nancy L Oleinick; Jeffrey L Duerk
Journal:  Lasers Surg Med       Date:  2007-10       Impact factor: 4.025

View more
  14 in total

1.  Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  J Am Med Inform Assoc       Date:  2013-06-12       Impact factor: 4.497

2.  Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

Authors:  Ioannis Sechopoulos; Kristina Bliznakova; Xulei Qin; Baowei Fei; Steve Si Jia Feng
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

3.  A multiscale and multiblock fuzzy C-means classification method for brain MR images.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

Review 4.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Cupping artifact correction and automated classification for high-resolution dedicated breast CT images.

Authors:  Xiaofeng Yang; Shengyong Wu; Ioannis Sechopoulos; Baowei Fei
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

6.  A Patch-based CBCT Scatter Artifact Correction Using Prior CT.

Authors:  Xiaofeng Yang; Tian Liu; Xue Dong; Xiangyang Tang; Eric Elder; Walter J Curran; Anees Dhabaan
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

7.  Extracting Cardiac Myofiber Orientations from High Frequency Ultrasound Images.

Authors:  Xulei Qin; Zhibin Cong; Rong Jiang; Ming Shen; Mary B Wagner; Paul Kishbom; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-29

8.  A MR Brain Classification Method Based on Multiscale and Multiblock Fuzzy C-means.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  Int Conf Bioinform Biomed Eng       Date:  2011

9.  Breast tomosynthesis with monochromatic beams: a feasibility study using Monte Carlo simulations.

Authors:  A Malliori; K Bliznakova; I Sechopoulos; Z Kamarianakis; B Fei; N Pallikarakis
Journal:  Phys Med Biol       Date:  2014-08-01       Impact factor: 3.609

10.  Dosimetry in x-ray-based breast imaging.

Authors:  David R Dance; Ioannis Sechopoulos
Journal:  Phys Med Biol       Date:  2016-09-12       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.