Literature DB >> 23039675

Cupping artifact correction and automated classification for high-resolution dedicated breast CT images.

Xiaofeng Yang1, Shengyong Wu, Ioannis Sechopoulos, Baowei Fei.   

Abstract

PURPOSE: To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images.
METHODS: The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors' classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images.
RESULTS: The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors' automatic classification and manual segmentation were 91.6% ± 2.0%.
CONCLUSIONS: A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution.

Entities:  

Mesh:

Year:  2012        PMID: 23039675      PMCID: PMC3477198          DOI: 10.1118/1.4754654

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  38 in total

1.  Parametric estimate of intensity inhomogeneities applied to MRI.

Authors:  M Styner; C Brechbühler; G Székely; G Gerig
Journal:  IEEE Trans Med Imaging       Date:  2000-03       Impact factor: 10.048

2.  Computerized assessment of tissue composition on digitized mammograms.

Authors:  Yuan-Hsiang Chang; Xiao-Hui Wang; Lara A Hardesty; Thomas S Chang; William R Poller; Walter F Good; David Gur
Journal:  Acad Radiol       Date:  2002-08       Impact factor: 3.173

3.  Automated detection of mass lesions in dedicated breast CT: a preliminary study.

Authors:  I Reiser; R M Nishikawa; M L Giger; J M Boone; K K Lindfors; K Yang
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

4.  Noise variance analysis using a flat panel x-ray detector: a method for additive noise assessment with application to breast CT applications.

Authors:  Kai Yang; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

5.  Correction of intensity variations in MR images for computer-aided tissue classification.

Authors:  B M Dawant; A P Zijdenbos; R A Margolin
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

6.  The myth of the 50-50 breast.

Authors:  M J Yaffe; J M Boone; N Packard; O Alonzo-Proulx; S Y Huang; C L Peressotti; A Al-Mayah; K Brock
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

7.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

Authors:  J G Sled; A P Zijdenbos; A C Evans
Journal:  IEEE Trans Med Imaging       Date:  1998-02       Impact factor: 10.048

8.  Computerized scene segmentation for the discrimination of architectural features in ductal proliferative lesions of the breast.

Authors:  N H Anderson; P W Hamilton; P H Bartels; D Thompson; R Montironi; J M Sloan
Journal:  J Pathol       Date:  1997-04       Impact factor: 7.996

9.  A wavelet multiscale denoising algorithm for magnetic resonance (MR) images.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  Meas Sci Technol       Date:  2011-02-01       Impact factor: 2.046

10.  A modified fuzzy C-means classification method using a multiscale diffusion filtering scheme.

Authors:  Hesheng Wang; Baowei Fei
Journal:  Med Image Anal       Date:  2008-07-05       Impact factor: 8.545

View more
  32 in total

1.  A general method for cupping artifact correction of cone-beam breast computed tomography images.

Authors:  Xiaolei Qu; Chao-Jen Lai; Yuncheng Zhong; Ying Yi; Chris C Shaw
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-29       Impact factor: 2.924

2.  Population of 224 realistic human subject-based computational breast phantoms.

Authors:  David W Erickson; Jered R Wells; Gregory M Sturgeon; Ehsan Samei; James T Dobbins; W Paul Segars; Joseph Y Lo
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  J Am Med Inform Assoc       Date:  2013-06-12       Impact factor: 4.497

4.  Automatic Segmentation of Right Ventricle on Ultrasound Images Using Sparse Matrix Transform and Level Set.

Authors:  Xulei Qin; Zhibin Cong; Luma V Halig; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-13

5.  Breast density evaluation using spectral mammography, radiologist reader assessment, and segmentation techniques: a retrospective study based on left and right breast comparison.

Authors:  Sabee Molloi; Huanjun Ding; Stephen Feig
Journal:  Acad Radiol       Date:  2015-05-29       Impact factor: 3.173

6.  A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

Authors:  Antonio Sarno; David R Dance; Ruben E van Engen; Kenneth C Young; Paolo Russo; Francesca Di Lillo; Giovanni Mettivier; Kristina Bliznakova; Baowei Fei; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2017-06-13       Impact factor: 4.071

Review 7.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Dosimetric study on learning-based cone-beam CT correction in adaptive radiation therapy.

Authors:  Tonghe Wang; Yang Lei; Nivedh Manohar; Sibo Tian; Ashesh B Jani; Hui-Kuo Shu; Kristin Higgins; Anees Dhabaan; Pretesh Patel; Xiangyang Tang; Tian Liu; Walter J Curran; Xiaofeng Yang
Journal:  Med Dosim       Date:  2019-04-01       Impact factor: 1.482

9.  Quantitative analysis for breast density estimation in low dose chest CT scans.

Authors:  Woo Kyung Moon; Chung-Ming Lo; Jin Mo Goo; Min Sun Bae; Jung Min Chang; Chiun-Sheng Huang; Jeon-Hor Chen; Violeta Ivanova; Ruey-Feng Chang
Journal:  J Med Syst       Date:  2014-03-19       Impact factor: 4.460

10.  Library based x-ray scatter correction for dedicated cone beam breast CT.

Authors:  Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Lei Zhu
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.