Literature DB >> 23963892

Performance evaluation of a depth-of-interaction detector by use of position-sensitive PMT with a super-bialkali photocathode.

Yoshiyuki Hirano1, Munetaka Nitta, Naoko Inadama, Fumihiko Nishikido, Eiji Yoshida, Hideo Murayama, Taiga Yamaya.   

Abstract

Our purpose in this work was to evaluate the performance of a 4-layer depth-of-interaction (DOI) detector composed of GSO crystals by use of a position-sensitive photomultiplier tube (PMT) with a super-bialkali photocathode (SBA) by comparing it with a standard bialkali photocathode (BA) regarding the ability to identify the scintillating crystals, energy resolution, and timing resolution. The 4-layer DOI detector was composed of a 16 × 16 array of 2.9 × 2.9 × 7.5 mm(3) GSO crystals for each layer and an 8 × 8 multi-anode array type position-sensitive PMT. The DOI was achieved by a reflector control method, and the Anger method was used for calculating interacting points. The energy resolution in full width at half-maximum (FWHM) at 511 keV energy for the top layer (the farthest from the PMT) was improved and was 12.0% for the SBA compared with the energy resolution of 12.7% for the BA. As indicators of crystal identification ability, the peak-to-valley ratio and distance-to-width ratio were calculated; the latter was defined as the average of the distance between peaks per the average of the peak width. For both metrics, improvement of several percent was obtained; for example, the peak-to-valley ratio was increased from 1.78 (BA) to 1.86 (SBA), and the distance-to-width ratio was increased from 1.47 (BA) to 1.57 (SBA). The timing resolution (FWHM) in the bottom layer was improved slightly and was 2.4 ns (SBA) compared with 2.5 ns (BA). Better performance of the DOI detector is expected by use of a super bialkali photocathode.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23963892     DOI: 10.1007/s12194-013-0231-4

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  NEMA NU 2 performance tests for scanners with intrinsic radioactivity.

Authors:  Charles C Watson; Michael E Casey; Lars Eriksson; Tim Mulnix; Doug Adams; Bernard Bendriem
Journal:  J Nucl Med       Date:  2004-05       Impact factor: 10.057

2.  System design of a small OpenPET prototype with 4-layer DOI detectors.

Authors:  Eiji Yoshida; Shoko Kinouchi; Hideaki Tashima; Fumihiko Nishikido; Naoko Inadama; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2011-11-29

3.  Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT.

Authors:  Mikiko Ito; Jae Sung Lee; Min-Jae Park; Kwang-Souk Sim; Seong Jong Hong
Journal:  Phys Med Biol       Date:  2010-06-15       Impact factor: 3.609

4.  Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

Authors:  Seiichi Yamamoto; Hitoshi Horii; Mitsuru Hurutani; Keiichi Matsumoto; Michio Senda
Journal:  Ann Nucl Med       Date:  2005-04       Impact factor: 2.668

5.  Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out.

Authors:  P A Dokhale; R W Silverman; K S Shah; R Grazioso; R Farrell; J Glodo; M A McClish; G Entine; V H Tran; S R Cherry
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

6.  A novel, SiPM-array-based, monolithic scintillator detector for PET.

Authors:  Dennis R Schaart; Herman T van Dam; Stefan Seifert; Ruud Vinke; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

7.  Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.

Authors:  Marnix C Maas; Dennis R Schaart; D J Jan van der Laan; Peter Bruyndonckx; Cedric Lemaître; Freek J Beekman; Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

8.  Analog signal multiplexing for PSAPD-based PET detectors: simulation and experimental validation.

Authors:  Frances W Y Lau; Arne Vandenbroucke; Paul D Reynolds; Peter D Olcott; Mark A Horowitz; Craig S Levin
Journal:  Phys Med Biol       Date:  2010-11-16       Impact factor: 3.609

9.  Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.

Authors:  Chad Bircher; Yiping Shao
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

10.  A proposal of an open PET geometry.

Authors:  Taiga Yamaya; Taku Inaniwa; Shinichi Minohara; Eiji Yoshida; Naoko Inadama; Fumihiko Nishikido; Kengo Shibuya; Chih Fung Lam; Hideo Murayama
Journal:  Phys Med Biol       Date:  2008-01-14       Impact factor: 3.609

View more