Literature DB >> 15136632

NEMA NU 2 performance tests for scanners with intrinsic radioactivity.

Charles C Watson1, Michael E Casey, Lars Eriksson, Tim Mulnix, Doug Adams, Bernard Bendriem.   

Abstract

Performance tests on lutetium oxyorthosilicate (LSO)-based PET scanners cannot be conducted strictly according to the National Electrical Manufacturers Association (NEMA) NU 2 standards because of the presence of intrinsic radioactivity within the LSO crystal scintillator material. This background radiation gives rise mainly to random coincidence events but also to a small number of true coincidences, which cannot be eliminated from measurements on such scanners and must therefore be corrected for in the data analysis. The current NU 2 standards do not take account of these backgrounds and hence can lead to erroneous results on LSO-based machines. Nevertheless, the intent of the standards can be met with appropriate modifications to the acquisition and processing procedures. In this paper, we propose certain changes to the NEMA specifications to accommodate this class of scanners. These changes affect mainly the estimation of sensitivity, scatter, randoms, and count losses. Using these modified procedures, the NU 2 performance of LSO-based systems can accurately be measured.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15136632

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  15 in total

1.  Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method.

Authors:  Qinan Bao; Arion F Chatziioannou
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging.

Authors:  Keiichi Magota; Naoki Kubo; Yuji Kuge; Ken-Ichi Nishijima; Songji Zhao; Nagara Tamaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-12-10       Impact factor: 9.236

3.  Reduction method for intrinsic random coincidence events from (176)Lu in low activity PET imaging.

Authors:  Eiji Yoshida; Hideaki Tashima; Fumihiko Nishikido; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-02-05

4.  National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner.

Authors:  Kira S Grogg; Terrence Toole; Jinsong Ouyang; Xuping Zhu; Marc D Normandin; Quanzheng Li; Keith Johnson; Nathaniel M Alpert; Georges El Fakhri
Journal:  J Nucl Med       Date:  2015-12-23       Impact factor: 10.057

5.  Performance evaluation of an Inveon PET preclinical scanner.

Authors:  Cristian C Constantinescu; Jogeshwar Mukherjee
Journal:  Phys Med Biol       Date:  2009-04-21       Impact factor: 3.609

6.  Performance and limitations of positron emission tomography (PET) scanners for imaging very low activity sources.

Authors:  Melissa I Freedenberg; Ramsey D Badawi; Alice F Tarantal; Simon R Cherry
Journal:  Phys Med       Date:  2013-05-14       Impact factor: 2.685

7.  Performance evaluation of a depth-of-interaction detector by use of position-sensitive PMT with a super-bialkali photocathode.

Authors:  Yoshiyuki Hirano; Munetaka Nitta; Naoko Inadama; Fumihiko Nishikido; Eiji Yoshida; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2013-08-21

8.  Clinical imaging characteristics of the positron emission mammography camera: PEM Flex Solo II.

Authors:  Lawrence MacDonald; John Edwards; Thomas Lewellen; David Haseley; James Rogers; Paul Kinahan
Journal:  J Nucl Med       Date:  2009-09-16       Impact factor: 10.057

9.  Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards.

Authors:  Qinan Bao; Danny Newport; Mu Chen; David B Stout; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057

10.  NEMA NU 2-2007 performance measurements of the Siemens Inveon preclinical small animal PET system.

Authors:  Brad J Kemp; Carrie B Hruska; Aaron R McFarland; Mark W Lenox; Val J Lowe
Journal:  Phys Med Biol       Date:  2009-03-25       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.