Literature DB >> 21081831

Analog signal multiplexing for PSAPD-based PET detectors: simulation and experimental validation.

Frances W Y Lau1, Arne Vandenbroucke, Paul D Reynolds, Peter D Olcott, Mark A Horowitz, Craig S Levin.   

Abstract

A 1 mm(3) resolution clinical positron emission tomography (PET) system employing 4608 position-sensitive avalanche photodiodes (PSAPDs) is under development. This paper describes a detector multiplexing technique that simplifies the readout electronics and reduces the density of the circuit board design. The multiplexing scheme was validated using a simulation framework that models the PSAPDs and front-end multiplexing circuits to predict the signal-to-noise ratio and flood histogram performance. Two independent experimental setups measured the energy resolution, time resolution, crystal identification ability and count rate both with and without multiplexing. With multiplexing, there was no significant degradation in energy resolution, time resolution and count rate. There was a relative 6.9 ± 1.0% and 9.4 ± 1.0% degradation in the figure of merit that characterizes the crystal identification ability observed in the measured and simulated ceramic-mounted PSAPD module flood histograms, respectively.

Entities:  

Mesh:

Year:  2010        PMID: 21081831      PMCID: PMC3691840          DOI: 10.1088/0031-9155/55/23/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Effects of multiple-interaction photon events in a high-resolution PET system that uses 3-D positioning detectors.

Authors:  Yi Gu; Guillem Pratx; Frances W Y Lau; Craig S Levin
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out.

Authors:  P A Dokhale; R W Silverman; K S Shah; R Grazioso; R Farrell; J Glodo; M A McClish; G Entine; V H Tran; S R Cherry
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

3.  A new timing model for calculating the intrinsic timing resolution of a scintillator detector.

Authors:  Yiping Shao
Journal:  Phys Med Biol       Date:  2007-01-25       Impact factor: 3.609

4.  Convex optimization of coincidence time resolution for a high-resolution PET system.

Authors:  Paul D Reynolds; Peter D Olcott; Guillem Pratx; Frances W Y Lau; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2010-09-27       Impact factor: 10.048

5.  The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements.

Authors:  Raymond R Raylman; Stan Majewski; Mark F Smith; James Proffitt; William Hammond; Amarnath Srinivasan; John McKisson; Vladimir Popov; Andrew Weisenberger; Clifford O Judy; Brian Kross; Srikanth Ramasubramanian; Larry E Banta; Paul E Kinahan; Kyle Champley
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

6.  PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

Authors:  Martin S Judenhofer; Ciprian Catana; Brian K Swann; Stefan B Siegel; Wulf-Ingo Jung; Robert E Nutt; Simon R Cherry; Claus D Claussen; Bernd J Pichler
Journal:  Radiology       Date:  2007-09       Impact factor: 11.105

7.  Dedicated PET scanners for breast imaging.

Authors:  R Freifelder; J S Karp
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

8.  Positron emission mammography: high-resolution biochemical breast imaging.

Authors:  Irving N Weinberg; David Beylin; Valera Zavarzin; Steve Yarnall; Pavel Y Stepanov; Edward Anashkin; Deepa Narayanan; Sergei Dolinsky; Kathrin Lauckner; Lee P Adler
Journal:  Technol Cancer Res Treat       Date:  2005-02

9.  Bayesian reconstruction of photon interaction sequences for high-resolution PET detectors.

Authors:  Guillem Pratx; Craig S Levin
Journal:  Phys Med Biol       Date:  2009-08-04       Impact factor: 3.609

10.  Impact of high energy resolution detectors on the performance of a PET system dedicated to breast cancer imaging.

Authors:  Craig S Levin; Angela M K Foudray; Frezghi Habte
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

View more
  9 in total

Review 1.  Promising new photon detection concepts for high-resolution clinical and preclinical PET.

Authors:  Craig S Levin
Journal:  J Nucl Med       Date:  2012-02       Impact factor: 10.057

2.  Optical delay encoding for fast timing and detector signal multiplexing in PET.

Authors:  Alexander M Grant; Craig S Levin
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Convex optimization of coincidence time resolution for a high-resolution PET system.

Authors:  Paul D Reynolds; Peter D Olcott; Guillem Pratx; Frances W Y Lau; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2010-09-27       Impact factor: 10.048

4.  Development of 1.45-mm resolution four-layer DOI-PET detector for simultaneous measurement in 3T MRI.

Authors:  Fumihiko Nishikido; Atsushi Tachibana; Takayuki Obata; Naoko Inadama; Eiji Yoshida; Mikio Suga; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-10-28

5.  Thermal regulation of tightly packed solid-state photodetectors in a 1 mm(3) resolution clinical PET system.

Authors:  D L Freese; A Vandenbroucke; D Innes; F W Y Lau; D F C Hsu; P D Reynolds; Craig S Levin
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

6.  Compact pulse width modulation circuitry for silicon photomultiplier readout.

Authors:  M F Bieniosek; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2013-07-08       Impact factor: 3.609

7.  Performance Comparison of Different Readouts for Position-Sensitive Solid-State Photomultiplier Arrays.

Authors:  Junwei Du; Jeffrey P Schmall; Kun Di; Yongfeng Yang; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Biomed Phys Eng Express       Date:  2017-07-19

8.  A Simple Capacitive Charge-Division Readout for Position-Sensitive Solid-State Photomultiplier Arrays.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

9.  Performance evaluation of a depth-of-interaction detector by use of position-sensitive PMT with a super-bialkali photocathode.

Authors:  Yoshiyuki Hirano; Munetaka Nitta; Naoko Inadama; Fumihiko Nishikido; Eiji Yoshida; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2013-08-21
  9 in total