Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

Seiichi Yamamoto1, Hitoshi Horii, Mitsuru Hurutani, Keiichi Matsumoto, Michio Senda.   

Abstract

OBJECTIVE: Lutetium oxyorthosilicate (LSO) contains natural radioactivity that emits beta particles and three gamma photons simultaneously. These beta particles and gamma photons increase the single and random rates in a positron emission tomography (PET) system while a beta particle and gamma photon produced in the same decay of Lu-176 and detected by another detector can be beta-gamma coincidence true events. The purpose of this work is to measure the single, random, and true count rates due to the natural radioactivity in LSO and determine the optimum lower energy threshold level for an energy window in an LSO-based clinical PET.
METHODS: First, we measured the energy spectra of these beta particles and gamma photons in LSO using a single crystal to obtain the basic data. Then, we measured single, random, and true count rates of an LSO-based clinical PET from the natural radioactivity as a function of the lower energy threshold.
RESULTS: In the PET, single and random count rates due to the natural background activity were gradually decreased as the lower energy threshold level increased. The true count rates due to the beta-gamma coincidence were more than 10 kcps below a lower energy threshold of 250 keV. However, these true count rates due to the natural radioactivity in LSO can be decreased to less than 1 kcps at a lower energy threshold level set at more than 350 keV.
CONCLUSION: With these considerations, in an LSO-based clinical PET, a lower energy threshold level set at above 350 keV is recommended.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15909490     DOI: 10.1007/BF03027389

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  12 in total

1.  System design of a small OpenPET prototype with 4-layer DOI detectors.

Authors:  Eiji Yoshida; Shoko Kinouchi; Hideaki Tashima; Fumihiko Nishikido; Naoko Inadama; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2011-11-29

2.  Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method.

Authors:  Qinan Bao; Arion F Chatziioannou
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  A GSO tweezers-type coincidence detector for tumor detection.

Authors:  Seiichi Yamamoto; Tatsuya Higashi; Michio Senda
Journal:  Radiol Phys Technol       Date:  2013-01-03

4.  Reduction method for intrinsic random coincidence events from (176)Lu in low activity PET imaging.

Authors:  Eiji Yoshida; Hideaki Tashima; Fumihiko Nishikido; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-02-05

5.  A method for measuring the energy spectrum of coincidence events in positron emission tomography.

Authors:  Andrew L Goertzen; David B Stout; Christopher J Thompson
Journal:  Phys Med Biol       Date:  2009-12-21       Impact factor: 3.609

6.  PET/CT imaging for treatment verification after proton therapy: a study with plastic phantoms and metallic implants.

Authors:  Katia Parodi; Harald Paganetti; Ethan Cascio; Jacob B Flanz; Ali A Bonab; Nathaniel M Alpert; Kevin Lohmann; Thomas Bortfeld
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

7.  Performance and limitations of positron emission tomography (PET) scanners for imaging very low activity sources.

Authors:  Melissa I Freedenberg; Ramsey D Badawi; Alice F Tarantal; Simon R Cherry
Journal:  Phys Med       Date:  2013-05-14       Impact factor: 2.685

8.  Performance evaluation of a depth-of-interaction detector by use of position-sensitive PMT with a super-bialkali photocathode.

Authors:  Yoshiyuki Hirano; Munetaka Nitta; Naoko Inadama; Fumihiko Nishikido; Eiji Yoshida; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2013-08-21

9.  Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards.

Authors:  Qinan Bao; Danny Newport; Mu Chen; David B Stout; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057

10.  Comparison of Imaging Characteristics of (124)I PET for Determination of Optimal Energy Window on the Siemens Inveon PET.

Authors:  A Ram Yu; Hee-Joung Kim; Sang Moo Lim; Jin Su Kim
Journal:  Biomed Res Int       Date:  2016-03-22       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.