Literature DB >> 23834273

Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

George Tsomos1, Björn Ludwig, Johannes Grossen, Pawel Pazera, Nikolaos Gkantidis.   

Abstract

OBJECTIVE: To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors.
MATERIALS AND METHODS: Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex.
RESULTS: There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58).
CONCLUSIONS: Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

Entities:  

Mesh:

Year:  2013        PMID: 23834273      PMCID: PMC8683054          DOI: 10.2319/042313-315.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  19 in total

1.  Intra-oral temperature variation over 24 hours.

Authors:  R J Moore; J T Watts; J A Hood; D J Burritt
Journal:  Eur J Orthod       Date:  1999-06       Impact factor: 3.075

2.  A microsensor for monitoring removable-appliance wear.

Authors:  Timm Cornelius Schott; Björn Ludwig; Bettina A Glasl; Jörg A Lisson
Journal:  J Clin Orthod       Date:  2011-09

3.  An accurate, inexpensive headgear timer.

Authors:  S L Cureton; F Regennitter; M G Orbell
Journal:  J Clin Orthod       Date:  1991-12

4.  Micro-electronic monitoring of functional appliance wear.

Authors:  G Sahm; A Bartsch; E Witt
Journal:  Eur J Orthod       Date:  1990-08       Impact factor: 3.075

5.  Functional and social discomfort during orthodontic treatment--effects on compliance and prediction of patients' adaptation by personality variables.

Authors:  H G Sergl; U Klages; A Zentner
Journal:  Eur J Orthod       Date:  2000-06       Impact factor: 3.075

6.  Removable thermoplastic appliances as orthodontic retainers--a prospective study of different wear regimens.

Authors:  Sylvia Jäderberg; Ingalill Feldmann; Christer Engström
Journal:  Eur J Orthod       Date:  2011-04-20       Impact factor: 3.075

7.  Posttreatment compliance with removable maxillary retention in a teenage population: a short-term randomized clinical trial.

Authors:  Marc Bernard Ackerman; Barry Thornton
Journal:  Orthodontics (Chic.)       Date:  2011

8.  Correlates of objective patient compliance with removable appliance wear.

Authors:  A Bartsch; E Witt; G Sahm; S Schneider
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-10       Impact factor: 2.650

9.  Comparing subjective and objective measures of headgear compliance.

Authors:  Annemieke Bos; Cornelis J Kleverlaan; Johan Hoogstraten; Birte Prahl-Andersen; Rein Kuitert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-12       Impact factor: 2.650

10.  Clinical and quantitative assessment of headgear compliance: a pilot study.

Authors:  Márcia Brandão; Heloisa Saad Pinho; Dayse Urias
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-02       Impact factor: 2.650

View more
  22 in total

1.  Aesthetic Retainer cum Trainer.

Authors:  Tulika Tripathi; Shilpa Kalra; Priyank Rai
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  Smartphone-based application for EMA assessment of awake bruxism: compliance evaluation in a sample of healthy young adults.

Authors:  Anna Colonna; Luca Lombardo; Giuseppe Siciliani; Alessandro Bracci; Luca Guarda-Nardini; Goran Djukic; Daniele Manfredini
Journal:  Clin Oral Investig       Date:  2019-10-24       Impact factor: 3.573

3.  Evaluation of relapse with thermoplastic retainers equipped with microsensors.

Authors:  Sait İshakoğlu; Serpil Çokakoğlu
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

4.  Assessment of Factors Affecting Adolescent Patients' Compliance with Hawley and Vacuum Formed Retainers.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi
Journal:  J Clin Diagn Res       Date:  2016-06-01

5.  How patient-selected colors for removable appliances are reflected in electronically tracked compliance (wear times and wear behavior).

Authors:  Timm C Schott; Dieter Menne
Journal:  Angle Orthod       Date:  2018-03-27       Impact factor: 2.079

6.  Patient compliance and orthodontic treatment efficacy of Planas functional appliances with TheraMon microsensors.

Authors:  Carole Charavet; Michel Le Gall; Adelin Albert; Annick Bruwier; Sophie Leroy
Journal:  Angle Orthod       Date:  2018-08-03       Impact factor: 2.079

7.  Comparison of two early treatment protocols for anterior dental crossbite in the mixed dentition: A randomized trial.

Authors:  Cristina B Miamoto; Leandro S Marques; Lucas G Abreu; Saul M Paiva
Journal:  Angle Orthod       Date:  2017-11-06       Impact factor: 2.079

8.  Invisalign treatment from the patient perspective: A Twitter content analyses.

Authors:  Milagros Adobes-Martin; Maria-Luisa Montoya-Morcillo; Angel Zhou-Wu; Daniele Garcovich
Journal:  J Clin Exp Dent       Date:  2021-04-01

Review 9.  Robotic Applications in Orthodontics: Changing the Face of Contemporary Clinical Care.

Authors:  Samar Adel; Abbas Zaher; Nadia El Harouni; Adith Venugopal; Pratik Premjani; Nikhilesh Vaid
Journal:  Biomed Res Int       Date:  2021-06-16       Impact factor: 3.411

10.  Quantification of wear-time adherence of removable appliances in young orthodontic patients in relation to their BMI: a preliminary study.

Authors:  Timm Cornelius Schott; Björn Ludwig
Journal:  Patient Prefer Adherence       Date:  2014-11-17       Impact factor: 2.711

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.