Literature DB >> 28274080

Aesthetic Retainer cum Trainer.

Tulika Tripathi1, Shilpa Kalra2, Priyank Rai3.   

Abstract

Tongue thrust habit is one of the contributing factors in the relapse of orthodontic treatment results. Compliance with removable habit breaking appliance is a major issue to the dental practitioners treating patients of any age group. Through this case we introduce a more aesthetic and comfortable option to the patients requiring habit control for tongue thrusting and retention of treatment results. Hence, this appliance acts as a retainer cum trainer in such patients.

Entities:  

Keywords:  Habit breaking; Retention; Tongue thrust

Year:  2017        PMID: 28274080      PMCID: PMC5324525          DOI: 10.7860/JCDR/2017/23107.9153

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  8 in total

1.  The role of removable appliances in contemporary orthodontics.

Authors:  S J Littlewood; A G Tait; N A Mandall; D H Lewis
Journal:  Br Dent J       Date:  2001-09-22       Impact factor: 1.626

2.  Tongue muscle activity after orthodontic treatment of anterior open bite: a case report.

Authors:  K Yashiro; K Takada
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-06       Impact factor: 2.650

3.  Stability of anterior openbite treated with crib therapy.

Authors:  G J Huang; R Justus; D B Kennedy; V G Kokich
Journal:  Angle Orthod       Date:  1990       Impact factor: 2.079

4.  Orthodontic appliances and enamel demineralization. Part 1. Lesion development.

Authors:  B Ogaard; G Rølla; J Arends
Journal:  Am J Orthod Dentofacial Orthop       Date:  1988-07       Impact factor: 2.650

5.  Tongue-thrust and the stability of overjet correction.

Authors:  M V Andrianopoulos; M L Hanson
Journal:  Angle Orthod       Date:  1987-04       Impact factor: 2.079

6.  Stability of maxillary surgery in openbite versus nonopenbite malocclusions.

Authors:  T F Denison; V G Kokich; P A Shapiro
Journal:  Angle Orthod       Date:  1989       Impact factor: 2.079

7.  Surface distribution of enamel opacities following orthodontic treatment.

Authors:  E Mizrahi
Journal:  Am J Orthod       Date:  1983-10

8.  Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Authors:  George Tsomos; Björn Ludwig; Johannes Grossen; Pawel Pazera; Nikolaos Gkantidis
Journal:  Angle Orthod       Date:  2013-07-08       Impact factor: 2.079

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.