Literature DB >> 30080129

Patient compliance and orthodontic treatment efficacy of Planas functional appliances with TheraMon microsensors.

Carole Charavet, Michel Le Gall, Adelin Albert, Annick Bruwier, Sophie Leroy.   

Abstract

OBJECTIVES: To assess patient compliance and treatment efficacy of preventive expansion treatment with removable Planas functional appliances using an integrated microsensor.
MATERIALS AND METHODS: Wear time (WT) and behavior of 69 patients undergoing treatment with Planas functional appliances were assessed and analysed using TheraMon microsensors (Gschladt, Hargelsberg, Austria). Patients were followed up for a period of 9 months, and visits were made every 3 months to download WT data from the microsensor and to assess wearing behavior. From individual WT graphs,10 parameters were derived to characterize compliance for each patient. Treatment efficacy was measured by eight parameters determining the level of expansion after 9 months of treatment.
RESULTS: Patients wore their device on average 15.8 ± 5.2 h/d. WT was unrelated to age and gender, but it was positively influenced by patient habits when keeping appliances during eating, sports, care and handling. Treatment efficacy in terms of intercanine and intermolar expansion was 4.4 ± 1.9 mm and 4.6 ± 2.0 mm for the maxilla, and 5.3 ± 2.0 mm and 4.7 ± 2.3 mm for the mandible, respectively. Efficacy was negatively affected by poor compliance (WT < 9 h/d) and by high variability of within-subject WT recordings.
CONCLUSIONS: Perfect compliance is not necessary to achieve treatment success, but patients should exhibit sufficient wear time to allow maxillary expansion to occur. The TheraMon microsensor offers a new perspective and aid to individualize treatment prescriptions.

Entities:  

Keywords:  Compliance; Functional appliances; Microsensor

Mesh:

Year:  2018        PMID: 30080129      PMCID: PMC8137129          DOI: 10.2319/122917-888.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  25 in total

1.  Applicative characteristics of new microelectronic sensors Smart Retainer® and TheraMon® for measuring wear time.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-10-21       Impact factor: 1.938

2.  [Homage to Pedro Planas].

Authors:  K Canalda
Journal:  Actual Odontostomatol (Paris)       Date:  1990-12

Review 3.  [The wear-timing measuring device in orthodontics--cui bono? Reflections on the state-of-the-art in wear-timing measurement and compliance research in orthodontics].

Authors:  E Witt; A Bartsch; G Sahm
Journal:  Fortschr Kieferorthop       Date:  1991-06

4.  Micro-electronic monitoring of functional appliance wear.

Authors:  G Sahm; A Bartsch; E Witt
Journal:  Eur J Orthod       Date:  1990-08       Impact factor: 3.075

5.  Functional and social discomfort during orthodontic treatment--effects on compliance and prediction of patients' adaptation by personality variables.

Authors:  H G Sergl; U Klages; A Zentner
Journal:  Eur J Orthod       Date:  2000-06       Impact factor: 3.075

6.  Correlates of objective patient compliance with removable appliance wear.

Authors:  A Bartsch; E Witt; G Sahm; S Schneider
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-10       Impact factor: 2.650

7.  Microelectronic wear-time documentation of removable orthodontic devices detects heterogeneous wear behavior and individualizes treatment planning.

Authors:  Timm Cornelius Schott; Björn Ludwig
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-08       Impact factor: 2.650

8.  Comparing subjective and objective measures of headgear compliance.

Authors:  Annemieke Bos; Cornelis J Kleverlaan; Johan Hoogstraten; Birte Prahl-Andersen; Rein Kuitert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-12       Impact factor: 2.650

9.  Prevalence of malocclusions in the early mixed dentition and orthodontic treatment need.

Authors:  Eve Tausche; Olaf Luck; Winfried Harzer
Journal:  Eur J Orthod       Date:  2004-06       Impact factor: 3.075

10.  Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Authors:  George Tsomos; Björn Ludwig; Johannes Grossen; Pawel Pazera; Nikolaos Gkantidis
Journal:  Angle Orthod       Date:  2013-07-08       Impact factor: 2.079

View more
  5 in total

1.  Smartphone-based application for EMA assessment of awake bruxism: compliance evaluation in a sample of healthy young adults.

Authors:  Anna Colonna; Luca Lombardo; Giuseppe Siciliani; Alessandro Bracci; Luca Guarda-Nardini; Goran Djukic; Daniele Manfredini
Journal:  Clin Oral Investig       Date:  2019-10-24       Impact factor: 3.573

Review 2.  Effectiveness of mobile phone applications in improving oral hygiene care and outcomes in orthodontic patients.

Authors:  Shankargouda Patil; Ismaeel Abker Hedad; Alhassen Abdurabu Jafer; Ghadah Khalid Abutaleb; Tahani Mohammed Arishi; Seham Abdullah Arishi; Hussam Abdullah Arishi; Mohammed Jafer; Anadha N Gujar; Shahrukh Khan; A Thirumal Raj
Journal:  J Oral Biol Craniofac Res       Date:  2020-11-17

3.  Assessment of Patient-Centered Outcomes When Treating Maxillary Constriction Using a Slow Removable Versus a Rapid Fixed Expansion Appliance in the Adolescence Period: A Randomized Controlled Trial.

Authors:  Nancy Rabah; Heba M Al-Ibrahim; Mohammad Y Hajeer; Mowaffak A Ajaj; Ghiath Mahmoud
Journal:  Cureus       Date:  2022-03-03

4.  Predicting patient experience of Invisalign treatment: An analysis using artificial neural network.

Authors:  Lin Xu; Li Mei; Ruiqi Lu; Yuan Li; Hanshi Li; Yu Li
Journal:  Korean J Orthod       Date:  2022-03-07       Impact factor: 1.361

5.  Orthodontic Compliance Assessment: A Systematic Review.

Authors:  Marek Nahajowski; Joanna Lis; Michał Sarul
Journal:  Int Dent J       Date:  2022-08-10       Impact factor: 2.607

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.