Literature DB >> 2401338

Micro-electronic monitoring of functional appliance wear.

G Sahm1, A Bartsch, E Witt.   

Abstract

Measurement of actual bionator wear has so far been confined to a few studies involving only small samples. In this study a micro-electronic timing device was used in a greater number of patients (53 children) after the system proved to be reliable in a pretest involving 18 subjects. The patients were 9-14 years of age and had a timing device fitted in their bionators over a period of 3-6 months. The data were read from the memory chip at the regular treatment sessions every 3-4 weeks. There was evidence that the patients averaged 7.65 hours per day of wear, thus fulfilling only 50-60 per cent of the orthodontist's requirements. Further details and implications of the measurements are discussed.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2401338     DOI: 10.1093/ejo/12.3.297

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  21 in total

1.  Applicative characteristics of new microelectronic sensors Smart Retainer® and TheraMon® for measuring wear time.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-10-21       Impact factor: 1.938

2.  [Recommended times for wearing removable appliances--the results of a survey].

Authors:  E Witt; A Bartsch; G Sahm
Journal:  Fortschr Kieferorthop       Date:  1992-04

Review 3.  [The wear-timing measuring device in orthodontics--cui bono? Reflections on the state-of-the-art in wear-timing measurement and compliance research in orthodontics].

Authors:  E Witt; A Bartsch; G Sahm
Journal:  Fortschr Kieferorthop       Date:  1991-06

4.  [The facial profile and personality picture in children].

Authors:  N Hofmann; A Bartsch; E Witt; K E Bühler
Journal:  Fortschr Kieferorthop       Date:  1992-04

5.  Performance of clear vacuum-formed thermoplastic retainers depending on retention protocol: a systematic review.

Authors:  Eleftherios G Kaklamanos; Maria Kourakou; Dimitrios Kloukos; Ioannis Doulis; Smaragda Kavvadia
Journal:  Odontology       Date:  2016-06-06       Impact factor: 2.634

Review 6.  Treatment effects of fixed functional appliances in patients with Class II malocclusion: a systematic review and meta-analysis.

Authors:  Vasileios F Zymperdikas; Vasiliki Koretsi; Spyridon N Papageorgiou; Moschos A Papadopoulos
Journal:  Eur J Orthod       Date:  2015-05-19       Impact factor: 3.075

7.  [The influence of information and communication in the orthodontic consultation and treatment visit. II. The communication style and compliance].

Authors:  A Bartsch; E Witt; M Marks
Journal:  Fortschr Kieferorthop       Date:  1995-01

8.  Maxillary expansion therapy with plates featuring a transverse screw: implications of patient compliance with wear-time and screw activation requirements.

Authors:  T C Schott; U Fritz; H Meyer-Gutknecht
Journal:  J Orofac Orthop       Date:  2014-03-05       Impact factor: 1.938

9.  [The clinical and psychological indicators of behavior in wearing a removable appliance].

Authors:  A Bartsch; E Witt; I Dietz; P Dietz
Journal:  Fortschr Kieferorthop       Date:  1993-06

10.  Methods to evaluate compliance of patients with removable appliances-survey results.

Authors:  H Meyer-Gutknecht; U Fritz; T C Schott
Journal:  J Orofac Orthop       Date:  2014-03-06       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.