Evaluation of relapse with thermoplastic retainers equipped with microsensors.

Sait İshakoğlu, Serpil Çokakoğlu.   

Abstract

OBJECTIVES: To examine relapse with thermoplastic retainers equipped with microsensors 1 year after treatment.
MATERIALS AND METHODS: A total of 42 patients (29 females, 13 males) treated with four premolar extractions were included in this study. Thermoplastic appliances equipped with TheraMon microsensors (Handelsagentur Gschladt, Hargelsberg, Austria) were used to assess daily wear time (DWT), and the patients were monitored at 2-month intervals for a period of 12 months. At the end of the follow-up, the following two groups were formed based on the mean DWT: short wear time (SWT; <9 h/d) and long wear time (LWT; ≥9 h/d). Digital models were constructed before treatment (T0), at debonding (T1), and 6 months (T2) and 12 months (T3) after debonding. Little's Irregularity Index (LII) and the intercanine and intermolar widths, arch lengths, overjet, and overbite were calculated based on the digital models. Data were analyzed statistically.
RESULTS: Irregularity and overjet increased, whereas transverse measurements and arch lengths decreased with time in both groups. During the retention period, overbite decreased in the SWT group but increased in the LWT group. There were significant differences between groups only in mandibular irregularity. The LII values of the SWT group were significantly higher than those of the LWT group for the T1-T2 and T1-T3 time intervals (P < .05).
CONCLUSIONS: A mean DWT less than 9 hours/day was inadequate for controlling irregularity within clinically acceptable limits. A wear time of at least 9 h/d is recommended for the maintenance of mandibular anterior alignment.
© 2022 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Microsensor; Relapse; Stability

Mesh:

Year:  2022        PMID: 35076691      PMCID: PMC9020389          DOI: 10.2319/072221-578.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.684


  28 in total

Review 1.  Vacuum-formed retainers: an overview.

Authors:  Maurice J Meade; Declan T Millett
Journal:  Dent Update       Date:  2015 Jan-Feb

Review 2.  Retention and relapse in clinical practice.

Authors:  S J Littlewood; S Kandasamy; G Huang
Journal:  Aust Dent J       Date:  2017-03       Impact factor: 2.291

3.  Patient compliance with Hawley retainers fitted with the SMART(®) sensor: a prospective clinical pilot study.

Authors:  Paul Hyun; Charles Brian Preston; Thikriat S Al-Jewair; Eunhae Park-Hyun; Sawsan Tabbaa
Journal:  Angle Orthod       Date:  2014-05-28       Impact factor: 2.079

4.  Posttreatment compliance with removable maxillary retention in a teenage population: a short-term randomized clinical trial.

Authors:  Marc Bernard Ackerman; Barry Thornton
Journal:  Orthodontics (Chic.)       Date:  2011

5.  Long-term assessment of orthodontic relapse.

Authors:  C Sadowsky; E I Sakols
Journal:  Am J Orthod       Date:  1982-12

6.  A comparison between indirect and objective wear-time assessment of removable orthodontic appliances.

Authors:  Timm C Schott; Hannes Meyer-Gutknecht; Nicolai Mayer; Joachim Weber; Katja Weimer
Journal:  Eur J Orthod       Date:  2017-04-01       Impact factor: 3.075

7.  Evaluation of the effectiveness of a tailored mobile application in increasing the duration of wear of thermoplastic retainers: a randomized controlled trial.

Authors:  Dalya Al-Moghrabi; Nikolaos Pandis; Kieran McLaughlin; Ama Johal; Nikolaos Donos; Padhraig S Fleming
Journal:  Eur J Orthod       Date:  2020-11-03       Impact factor: 3.075

8.  Mandibular alignment changes after full-fixed orthodontic treatment: a systematic review and meta-analysis.

Authors:  Ahmad J Swidi; Andreea E Griffin; Peter H Buschang
Journal:  Eur J Orthod       Date:  2019-11-15       Impact factor: 3.075

Review 9.  The rationale for orthodontic retention: piecing together the jigsaw.

Authors:  Declan Millett
Journal:  Br Dent J       Date:  2021-06-11       Impact factor: 1.626

10.  Tooth-size discrepancy: a comparison between manual and digital methods.

Authors:  Gabriele Dória Cabral Correia; Fernando Antonio Lima Habib; Carlos Jorge Vogel
Journal:  Dental Press J Orthod       Date:  2014 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.